{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T19:43:33Z","timestamp":1792611813934,"version":"4.5.0"},"reference-count":43,"publisher":"MyJove Corporation","issue":"188","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JoVE"],"DOI":"10.3791\/63732","type":"journal-article","created":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T12:14:57Z","timestamp":1668168897000},"source":"Crossref","is-referenced-by-count":0,"title":["Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices during Thyroid and Parathyroid Surgery in a Porcine Model"],"prefix":"10.3791","author":[{"given":"Hsin-Yi","family":"Tseng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tzu-Yen","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia Joanna","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-Chu","family":"Lin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I-Cheng","family":"Lu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feng-Yu","family":"Chiang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianlorenzo","family":"Dionigi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory W.","family":"Randolph","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Che-Wei","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2098","published-online":{"date-parts":[[2022,10,13]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"793431","DOI":"10.3389\/fendo.2021.793431","type":"journal-article","article-title":"Improving voice outcomes after thyroid surgery - review of safety parameters for using energy-based devices near the recurrent laryngeal nerve","volume":"12","author":"Wang","year":"2021","unstructured":"Wang, J. J. et al. Improving voice outcomes after thyroid surgery - review of safety parameters for using energy-based devices near the recurrent laryngeal nerve. Front Endocrinol. 12, 793431 (2021).","journal-title":"Front Endocrinol"},{"issue":"11","key":"ref2","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1007\/s12325-009-0078-6","type":"journal-article","article-title":"LigaSure versus clamp-and-tie in thyroidectomy: a single-center experience","volume":"26","author":"Cakabay","year":"2009","unstructured":"Cakabay, B. et al. LigaSure versus clamp-and-tie in thyroidectomy: a single-center experience. Advances in Therapy. 26 (11), 1035-1041 (2009).","journal-title":"Advances in Therapy"},{"issue":"10","key":"ref3","doi-asserted-by":"crossref","first-page":"3677","DOI":"10.1002\/hed.25884","type":"journal-article","article-title":"Comparison of hypocalcemia rates between LigaSure and clamp-and-tie hemostatic technique in total thyroidectomies","volume":"41","author":"Chiang","year":"2019","unstructured":"Chiang, F. Y. et al. Comparison of hypocalcemia rates between LigaSure and clamp-and-tie hemostatic technique in total thyroidectomies. Head & Neck. 41 (10), 3677-3683 (2019).","journal-title":"Head & Neck"},{"key":"ref4","first-page":"313","type":"journal-article","article-title":"Comparison of surgical complications rates between LigaSure small jaw and clamp-and-tie hemostatic technique in 1,000 neuro-monitored thyroidectomies","volume":"12","author":"Liu","year":"2021","unstructured":"Liu, C.-H. et al. Comparison of surgical complications rates between LigaSure small jaw and clamp-and-tie hemostatic technique in 1,000 neuro-monitored thyroidectomies. Frontiers in Endocrinology. 12, 313 (2021).","journal-title":"Frontiers in Endocrinology"},{"issue":"4","key":"ref5","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1007\/s13304-020-00776-9","type":"journal-article","article-title":"Energy vessel sealant devices are associated with decreased risk of neck hematoma after thyroid surgery","volume":"72","author":"Moran","year":"2020","unstructured":"Moran, K. et al. Energy vessel sealant devices are associated with decreased risk of neck hematoma after thyroid surgery. Updates in Surgery. 72 (4), 1135-1141 (2020).","journal-title":"Updates in Surgery"},{"issue":"12","key":"ref6","doi-asserted-by":"crossref","first-page":"651","DOI":"10.3390\/medicina56120651","type":"journal-article","article-title":"Energy based vessel sealing devices in thyroid surgery: a systematic review to clarify the relationship with recurrent laryngeal nerve injuries","volume":"56","author":"Pacilli","year":"2020","unstructured":"Pacilli, M. et al. Energy based vessel sealing devices in thyroid surgery: a systematic review to clarify the relationship with recurrent laryngeal nerve injuries. Medicina. 56 (12), 651 (2020).","journal-title":"Medicina"},{"issue":"9","key":"ref7","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1089\/thy.2012.0588","type":"journal-article","article-title":"Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies","volume":"23","author":"Garas","year":"2013","unstructured":"Garas, G. et al. Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies. Thyroid. 23 (9), 1138-1150 (2013).","journal-title":"Thyroid"},{"issue":"2","key":"ref8","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.surg.2013.08.015","type":"journal-article","article-title":"Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: A porcine model","volume":"155","author":"Wu","year":"2014","unstructured":"Wu, C. W. et al. Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: A porcine model. Surgery. 155 (2), 329-339 (2014).","journal-title":"Surgery"},{"issue":"5","key":"ref9","doi-asserted-by":"crossref","first-page":"473","DOI":"10.21037\/gs.2016.09.06","type":"journal-article","article-title":"Intraoperative neural monitoring in thyroid surgery: lessons learned from animal studies","volume":"5","author":"Wu","year":"2016","unstructured":"Wu, C.-W. et al. Intraoperative neural monitoring in thyroid surgery: lessons learned from animal studies. Gland Surgery. 5 (5), 473-480 (2016).","journal-title":"Gland Surgery"},{"issue":"6","key":"ref10","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1007\/s00268-016-3415-3","type":"journal-article","article-title":"Severity of recurrent laryngeal nerve injuries in thyroid surgery","volume":"40","author":"Dionigi","year":"2016","unstructured":"Dionigi, G. et al. Severity of recurrent laryngeal nerve injuries in thyroid surgery. World Journal of Surgery. 40 (6), 1373-1381 (2016).","journal-title":"World Journal of Surgery"},{"issue":"1","key":"ref11","first-page":"19","type":"journal-article","article-title":"Recurrent laryngeal nerve (RLN) injury in thyroid surgery: lessons learned from the intraoperative neural monitoring (IONM)","volume":"1","author":"Wu","year":"2017","unstructured":"Wu, C. W. et al. Recurrent laryngeal nerve (RLN) injury in thyroid surgery: lessons learned from the intraoperative neural monitoring (IONM). International Journal of Head and Neck Science . 1 (1), 19-26 (2017).","journal-title":"International Journal of Head and Neck Science"},{"issue":"9","key":"ref12","doi-asserted-by":"crossref","first-page":"2601","DOI":"10.1007\/s00464-012-2239-y","type":"journal-article","article-title":"Recurrent laryngeal nerve injury in video-assisted thyroidectomy: lessons learned from neuromonitoring","volume":"26","author":"Dionigi","year":"2012","unstructured":"Dionigi, G. et al. Recurrent laryngeal nerve injury in video-assisted thyroidectomy: lessons learned from neuromonitoring. 26 (9), 2601-2608 (2012).","journal-title":"Surg Endosc"},{"issue":"3","key":"ref13","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1007\/s00423-008-0454-8","type":"journal-article","article-title":"Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments","volume":"394","author":"Dionigi","year":"2009","unstructured":"Dionigi, G. Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments. Langenbeck's Archives of Surgery. 394 (3), 579-580 (2009).","journal-title":"Langenbeck's Archives of Surgery"},{"issue":"6","key":"ref14","first-page":"1167","type":"journal-article","article-title":"Medicolegal analysis of errors in diagnosis and treatment of surgical endocrine disease","volume":"114","author":"Kern","year":"1993","unstructured":"Kern, K. A. Medicolegal analysis of errors in diagnosis and treatment of surgical endocrine disease. Surgery. 114 (6), 1167-1174 (1993).","journal-title":"Surgery"},{"issue":"144","key":"ref15","first-page":"e57919","type":"journal-article","article-title":"Intra-operative neural monitoring of thyroid surgery in a porcine model","author":"Wu","year":"2019","unstructured":"Wu, C. W. et al. Intra-operative neural monitoring of thyroid surgery in a porcine model. Journal of Visualized Experiments. (144), e57919 (2019).","journal-title":"Journal of Visualized Experiments"},{"issue":"10","key":"ref16","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1002\/hed.21324","type":"journal-article","article-title":"Investigation of optimal intensity and safety of electrical nerve stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve: a prospective porcine model","volume":"32","author":"Wu","year":"2010","unstructured":"Wu, C. W. et al. Investigation of optimal intensity and safety of electrical nerve stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve: a prospective porcine model. Head & Neck. 32 (10), 1295-1301 (2010).","journal-title":"Head & Neck"},{"issue":"5","key":"ref17","doi-asserted-by":"crossref","first-page":"490","DOI":"10.21037\/gs.2016.09.01","type":"journal-article","article-title":"Safety of energy based devices for hemostasis in thyroid surgery","volume":"5","author":"Dionigi","year":"2016","unstructured":"Dionigi, G. et al. Safety of energy based devices for hemostasis in thyroid surgery. Gland Surgery. 5 (5), 490 (2016).","journal-title":"Gland Surgery"},{"issue":"10","key":"ref18","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1177\/000348941212101013","type":"journal-article","article-title":"New animal model for assessment of functional laryngeal motor innervation","volume":"121","author":"Bj\u00f6rck","year":"2012","unstructured":"Bj\u00f6rck, G. et al. New animal model for assessment of functional laryngeal motor innervation. 121 (10), 695-699 (2012).","journal-title":"Ann Otol Rhinol Laryngol"},{"issue":"11","key":"ref19","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1089\/thy.2017.0680","type":"journal-article","article-title":"Feasibility of intraoperative neuromonitoring during thyroid surgery using transcartilage surface recording electrodes","volume":"28","author":"Wu","year":"2018","unstructured":"Wu, C. W. et al. Feasibility of intraoperative neuromonitoring during thyroid surgery using transcartilage surface recording electrodes. Thyroid. 28 (11), 1508-1516 (2018).","journal-title":"Thyroid"},{"issue":"11","key":"ref20","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1089\/thy.2017.0679","type":"journal-article","article-title":"Transcutaneous recording during intraoperative neuromonitoring in thyroid surgery","volume":"28","author":"Wu","year":"2018","unstructured":"Wu, C. W. et al. Transcutaneous recording during intraoperative neuromonitoring in thyroid surgery. Thyroid. 28 (11), 1500-1507 (2018).","journal-title":"Thyroid"},{"issue":"6","key":"ref21","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.surg.2008.02.006","type":"journal-article","article-title":"The mechanism of recurrent laryngeal nerve injury during thyroid surgery--the application of intraoperative neuromonitoring","volume":"143","author":"Chiang","year":"2008","unstructured":"Chiang, F. Y. et al. The mechanism of recurrent laryngeal nerve injury during thyroid surgery--the application of intraoperative neuromonitoring. Surgery. 143 (6), 743-749 (2008).","journal-title":"Surgery"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/lary.21119","type":"journal-article","article-title":"Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement","volume":"121","author":"Randolph","year":"2011","unstructured":"Randolph, G. W. et al. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope. 121 (S1), S1-16 (2011).","journal-title":"Laryngoscope"},{"issue":"1598","key":"ref23","type":"journal-article","article-title":"Informed consent for intraoperative neural monitoring in thyroid and parathyroid surgery - consensus statement of the International Neural Monitoring Study Group","volume":"12","author":"Wu","year":"2021","unstructured":"Wu, C.-W. et al. Informed consent for intraoperative neural monitoring in thyroid and parathyroid surgery - consensus statement of the International Neural Monitoring Study Group. Frontiers in Endocrinology. 12 (1598) (2021).","journal-title":"Frontiers in Endocrinology"},{"issue":"2","key":"ref24","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/s00268-009-0316-8","type":"journal-article","article-title":"Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation","volume":"34","author":"Chiang","year":"2010","unstructured":"Chiang, F. Y. et al. Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation. World Journal of Surgery. 34 (2), 223-229 (2010).","journal-title":"World Journal of Surgery"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1002\/lary.27360","type":"journal-article","article-title":"International neuromonitoring study group guidelines 2018: Part II: Optimal recurrent laryngeal nerve management for invasive thyroid cancer-incorporation of surgical, laryngeal, and neural electrophysiologic data","volume":"128","author":"Wu","year":"2018","unstructured":"Wu, C. W. et al. International neuromonitoring study group guidelines 2018: Part II: Optimal recurrent laryngeal nerve management for invasive thyroid cancer-incorporation of surgical, laryngeal, and neural electrophysiologic data. Laryngoscope. 128 (S3), S18-S27 (2018).","journal-title":"Laryngoscope"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/lary.27359","type":"journal-article","article-title":"International neural monitoring study group guideline 2018 part I: Staging bilateral thyroid surgery with monitoring loss of signal","volume":"128","author":"Schneider","year":"2018","unstructured":"Schneider, R. et al. International neural monitoring study group guideline 2018 part I: Staging bilateral thyroid surgery with monitoring loss of signal. Laryngoscope. 128 (S3), S1-S17 (2018).","journal-title":"Laryngoscope"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"705346","DOI":"10.3389\/fendo.2021.705346","type":"journal-article","article-title":"Training courses in laryngeal nerve monitoring in thyroid and parathyroid surgery-The INMSG Consensus Statement","volume":"12","author":"Wu","year":"2021","unstructured":"Wu, C. W. et al. Training courses in laryngeal nerve monitoring in thyroid and parathyroid surgery-The INMSG Consensus Statement. Frontiers in Endocrinology. 12, 705346 (2021).","journal-title":"Frontiers in Endocrinology"},{"key":"ref28","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/S1743-9191(13)60014-X","type":"journal-article","article-title":"Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: a critical appraisal","volume":"11","author":"Dionigi","year":"2013","unstructured":"Dionigi, G. et al. Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: a critical appraisal. International Journal of Surgery. 11 (S1), S44_S46 (2013).","journal-title":"International Journal of Surgery"},{"issue":"5","key":"ref29","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1007\/s00423-009-0503-y","type":"journal-article","article-title":"A new anchor electrode design for continuous neuromonitoring of the recurrent laryngeal nerve by vagal nerve stimulations","volume":"394","author":"Schneider","year":"2009","unstructured":"Schneider, R. et al. A new anchor electrode design for continuous neuromonitoring of the recurrent laryngeal nerve by vagal nerve stimulations. Langenbecks Archives of Surgery. 394 (5), 903-910 (2009).","journal-title":"Langenbecks Archives of Surgery"},{"issue":"2","key":"ref30","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1002\/hed.26946","type":"journal-article","article-title":"Clarifying optimal outcome measures in intermittent and continuous laryngeal neuromonitoring","volume":"44","author":"Sinclair","year":"2021","unstructured":"Sinclair, C. F. et al. Clarifying optimal outcome measures in intermittent and continuous laryngeal neuromonitoring. Head & Neck. 44 (2), 460-471 (2021).","journal-title":"Head & Neck"},{"issue":"5","key":"ref31","doi-asserted-by":"crossref","first-page":"2295","DOI":"10.1007\/s00464-019-07312-w","type":"journal-article","article-title":"Steam induced by the activation of energy devices under a wet condition may cause thermal injury","volume":"34","author":"Hayami","year":"2020","unstructured":"Hayami, M. et al. Steam induced by the activation of energy devices under a wet condition may cause thermal injury. Surgical Endoscopy. 34 (5), 2295-2302 (2020).","journal-title":"Surgical Endoscopy"},{"issue":"12","key":"ref32","doi-asserted-by":"crossref","first-page":"4153","DOI":"10.1007\/s00464-019-06724-y","type":"journal-article","article-title":"Lateral thermal spread induced by energy devices: a porcine model to evaluate the influence on the recurrent laryngeal nerve","volume":"33","author":"Hayami","year":"2019","unstructured":"Hayami, M. et al. Lateral thermal spread induced by energy devices: a porcine model to evaluate the influence on the recurrent laryngeal nerve. 33 (12), 4153-4163 (2019).","journal-title":"Sure Endosc"},{"issue":"1","key":"ref33","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.jss.2011.03.005","type":"journal-article","article-title":"Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma","volume":"170","author":"Smith","year":"2011","unstructured":"Smith, C. T., Zarebczan, B., Alhefdhi, A., Chen, H. Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma. Journal of Surgical Research. 170 (1), 64-68 (2011).","journal-title":"Journal of Surgical Research"},{"issue":"9","key":"ref34","doi-asserted-by":"crossref","first-page":"2541","DOI":"10.1007\/s00464-012-2229-0","type":"journal-article","article-title":"Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments","volume":"26","author":"Seehofer","year":"2012","unstructured":"Seehofer, D. et al. Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments. Surgical Endoscopy. 26 (9), 2541-2549 (2012).","journal-title":"Surgical Endoscopy"},{"issue":"6","key":"ref35","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1007\/s00464-007-9650-9","type":"journal-article","article-title":"Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT)","volume":"22","author":"Kim","year":"2008","unstructured":"Kim, F. J. et al. Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT). Surgical Endoscopy. 22 (6), 1464-1469 (2008).","journal-title":"Surgical Endoscopy"},{"issue":"8","key":"ref36","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1002\/lary.25362","type":"journal-article","article-title":"Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model","volume":"125","author":"Lin","year":"2015","unstructured":"Lin, Y. C. et al. Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model. Laryngoscope. 125 (8), E283-290 (2015).","journal-title":"Laryngoscope"},{"issue":"1","key":"ref37","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.amjsurg.2017.04.013","type":"journal-article","article-title":"Safety assessment of the use of ultrasonic energy in the proximity of the recurrent laryngeal nerve in a porcine model","volume":"215","author":"Ch\u00e1vez","year":"2018","unstructured":"Ch\u00e1vez, K. V. et al. Safety assessment of the use of ultrasonic energy in the proximity of the recurrent laryngeal nerve in a porcine model. The American Journal of Surgery. 215 (1), 186-190 (2018).","journal-title":"The American Journal of Surgery"},{"issue":"12","key":"ref38","doi-asserted-by":"crossref","first-page":"2838","DOI":"10.1002\/lary.25412","type":"journal-article","article-title":"Recurrent laryngeal nerve safety parameters of the H armonic F ocus during thyroid surgery: Porcine model using continuous monitoring","volume":"125","author":"Wu","year":"2015","unstructured":"Wu, C. W. et al. Recurrent laryngeal nerve safety parameters of the H armonic F ocus during thyroid surgery: Porcine model using continuous monitoring. 125 (12), 2838-2845 (2015).","journal-title":"The Laryngoscope"},{"issue":"10","key":"ref39","doi-asserted-by":"crossref","first-page":"2931","DOI":"10.1002\/hed.26334","type":"journal-article","article-title":"Safety parameters of ferromagnetic device during thyroid surgery: Porcine model using continuous neuromonitoring","volume":"42","author":"Huang","year":"2020","unstructured":"Huang, T. Y. et al. Safety parameters of ferromagnetic device during thyroid surgery: Porcine model using continuous neuromonitoring. 42 (10), 2931-2940 (2020).","journal-title":"Head Neck"},{"issue":"7","key":"ref40","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.1002\/lary.26271","type":"journal-article","article-title":"Safety of LigaSure in recurrent laryngeal nerve dissection-porcine model using continuous monitoring","volume":"127","author":"Dionigi","year":"2017","unstructured":"Dionigi, G. et al. Safety of LigaSure in recurrent laryngeal nerve dissection-porcine model using continuous monitoring. The Laryngoscope. 127 (7), 1724-1729 (2017).","journal-title":"The Laryngoscope"},{"issue":"3","key":"ref41","doi-asserted-by":"crossref","first-page":"702","DOI":"10.21037\/gs.2020.03.17","type":"journal-article","article-title":"Safety of Ligasure exact dissector in thyroidectomy with continuous neuromonitoring: a porcine model","volume":"9","author":"Huang","year":"2020","unstructured":"Huang, T.-Y. et al. Safety of Ligasure exact dissector in thyroidectomy with continuous neuromonitoring: a porcine model. Gland Surgery. 9 (3), 702 (2020).","journal-title":"Gland Surgery"},{"issue":"6","key":"ref42","doi-asserted-by":"crossref","first-page":"285","DOI":"10.4174\/astr.2018.94.6.285","type":"journal-article","article-title":"Comparing the safety of harmonic ACE and ACE+ around the recurrent laryngeal nerve in swine models","volume":"94","author":"Kim","year":"2018","unstructured":"Kim, H. K., Chai, Y. J., Lee, H. Y., Kim, H. Y., & Dionigi, G. Comparing the safety of harmonic ACE and ACE+ around the recurrent laryngeal nerve in swine models. Annals of Surgical Treatment Research. 94 (6), 285-290 (2018).","journal-title":"Annals of Surgical Treatment Research"},{"issue":"1","key":"ref43","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.jss.2015.06.066","type":"journal-article","article-title":"Thermal injury of the recurrent laryngeal nerve by THUNDERBEAT during thyroid surgery: findings from continuous intraoperative neuromonitoring in a porcine model","volume":"200","author":"Kwak","year":"2016","unstructured":"Kwak, H. Y. et al. Thermal injury of the recurrent laryngeal nerve by THUNDERBEAT during thyroid surgery: findings from continuous intraoperative neuromonitoring in a porcine model. Journal of Surgical Research. 200 (1), 177-182 (2016).","journal-title":"Journal of Surgical Research"}],"container-title":["Journal of Visualized Experiments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jove.com\/t\/63732\/investigation-electrophysiological-thermographic-safety-parameters","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T19:15:02Z","timestamp":1792610102000},"score":1,"resource":{"primary":{"URL":"https:\/\/app.jove.com\/t\/63732"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,13]]},"references-count":43,"journal-issue":{"issue":"188","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.3791\/63732","relation":{},"ISSN":["1940-087X"],"issn-type":[{"value":"1940-087X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,13]]}}}