{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T15:57:03Z","timestamp":1792598223231,"version":"4.5.0"},"reference-count":62,"publisher":"MyJove Corporation","issue":"217","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JoVE"],"DOI":"10.3791\/67271","type":"journal-article","created":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T19:26:11Z","timestamp":1743189971000},"source":"Crossref","is-referenced-by-count":0,"title":["Artificial Lung Device Priming for In Situ Fiber Bundle Surface Grafting"],"prefix":"10.3791","author":[{"given":"Romario","family":"Pusey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Majin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Mokhammad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Betelihem","family":"Fre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kebisha","family":"Basukala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chika G.","family":"Okwuogori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keith","family":"Cook","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rei","family":"Ukita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Grogan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Skoog","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kagya","family":"Amoako","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2098","published-online":{"date-parts":[[2025,3,28]]},"reference":[{"key":"ref1","type":"book","volume-title":"Robbins and Cotran Pathologic Basis of Disease. 9th","author":"Kumar","year":"2015","unstructured":"Kumar, V., Abbas, A. K., Aster, J. C., Robbins, S. L. Robbins and Cotran Pathologic Basis of Disease. 9th ed. Elsevier, Philadelphia, PA (2015)."},{"issue":"S 1","key":"ref2","doi-asserted-by":"crossref","first-page":"003","DOI":"10.1055\/s-2006-939550","type":"journal-article","article-title":"An overview of the structure and function of thrombin","volume":"32","author":"Davie","year":"2006","unstructured":"Davie, E. W., Kulman, J. D. An overview of the structure and function of thrombin. Semin Thromb Hemost. 32 (S 1), 003-015 (2006).","journal-title":"Semin Thromb Hemost"},{"issue":"2","key":"ref3","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1182\/blood-2003-12-4195","type":"journal-article","article-title":"New anticoagulants","volume":"105","author":"Hirsh","year":"2005","unstructured":"Hirsh, J., O'Donnell, M., Weitz, J. I. New anticoagulants. Blood. 105 (2), 453-463 (2005).","journal-title":"Blood"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.2147\/TCRM.S92222","type":"journal-article","article-title":"New insights into the mechanisms of action of aspirin and its use in the prevention and treatment of arterial and venous thromboembolism","volume":"11","author":"Mekaj","year":"2015","unstructured":"Mekaj, Y. H., Daci, F. T., Mekaj, A. Y. New insights into the mechanisms of action of aspirin and its use in the prevention and treatment of arterial and venous thromboembolism. Ther Clin Risk Manag. 11, 1449-1456 (2015).","journal-title":"Ther Clin Risk Manag"},{"issue":"23","key":"ref5","doi-asserted-by":"crossref","first-page":"17073","DOI":"10.1021\/acs.chemrev.2c00344","type":"journal-article","article-title":"Zwitterionic biomaterials","volume":"122","author":"Li","year":"2022","unstructured":"Li, Q. et al. Zwitterionic biomaterials. Chem Rev. 122 (23), 17073-17154 (2022).","journal-title":"Chem Rev"},{"issue":"1","key":"ref6","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1002\/adma.201404059","type":"journal-article","article-title":"Molecular understanding and design of zwitterionic materials","volume":"27","author":"Shao","year":"2015","unstructured":"Shao, Q., Jiang, S. Molecular understanding and design of zwitterionic materials. Adv Mater. 27 (1), 15-26 (2015).","journal-title":"Adv Mater"},{"key":"ref7","type":"book","article-title":"The time course of clinical oxygenator failure due to clot formation","volume-title":"medRxiv","author":"Demarest","year":"2020","unstructured":"Demarest, C. T. et al. The time course of clinical oxygenator failure due to clot formation. medRxiv. (2020)."},{"key":"ref8","article-title":"ECMO anticoagulation: it's still the biggest challenge","author":"Maul","year":"2015","unstructured":"Maul, T. M. ECMO anticoagulation: it's still the biggest challenge. ASAIO 61st Annual Conference. (2015)."},{"issue":"3","key":"ref9","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1097\/MAT.0b013e31819740a0","type":"journal-article","article-title":"First experience with a paracorporeal artificial lung in humans","volume":"55","author":"Camboni","year":"2009","unstructured":"Camboni, D., Philipp, A., Arlt, M., Pfeiffer, M., Hilker, M., Schmid, C. First experience with a paracorporeal artificial lung in humans. Asaio J. 55 (3), 304-306 (2009).","journal-title":"Asaio J"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/BF02442653","type":"journal-article","article-title":"Novel method for fabricating capillary membrane oxygenators","volume":"16","author":"Gaylor","year":"1978","unstructured":"Gaylor, J. D., Mockros, L. F. Novel method for fabricating capillary membrane oxygenators. Med Biol Eng Comput. 16, 369-378 (1978).","journal-title":"Med Biol Eng Comput"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"120778","DOI":"10.1016\/j.biomaterials.2021.120778","type":"journal-article","article-title":"Combination of polycarboxybetaine coating and factor XII inhibitor reduces clot formation while preserving normal tissue coagulation during extracorporeal life support","volume":"272","author":"Naito","year":"2021","unstructured":"Naito, N. et al. Combination of polycarboxybetaine coating and factor XII inhibitor reduces clot formation while preserving normal tissue coagulation during extracorporeal life support. Biomaterials. 272, 120778 (2021).","journal-title":"Biomaterials"},{"issue":"6","key":"ref12","doi-asserted-by":"crossref","first-page":"1500646","DOI":"10.1002\/admi.201500646","type":"journal-article","article-title":"Multimodal, biomaterial-focused anticoagulation via superlow fouling zwitterionic functional groups coupled with anti-platelet nitric oxide release","volume":"3","author":"Amoako","year":"2016","unstructured":"Amoako, K. A., Sundaram, H. S., Suhaib, A., Jiang, S., Cook, K. E. Multimodal, biomaterial-focused anticoagulation via superlow fouling zwitterionic functional groups coupled with anti-platelet nitric oxide release. Adv Mater Interfaces. 3 (6), 1500646 (2016).","journal-title":"Adv Mater Interfaces"},{"issue":"11","key":"ref13","doi-asserted-by":"crossref","first-page":"9255","DOI":"10.1021\/acsami.7b01530","type":"journal-article","article-title":"Achieving ultralow fouling under ambient conditions via surface-initiated ARGET ATRP of carboxybetaine","volume":"9","author":"Hong","year":"2017","unstructured":"Hong, D. et al. Achieving ultralow fouling under ambient conditions via surface-initiated ARGET ATRP of carboxybetaine. ACS Appl Mater Interfaces. 9 (11), 9255-9259 (2017).","journal-title":"ACS Appl Mater Interfaces"},{"issue":"6","key":"ref14","doi-asserted-by":"crossref","first-page":"1400071","DOI":"10.1002\/admi.201400071","type":"journal-article","article-title":"Achieving one-step surface coating of highly hydrophilic poly (carboxybetaine methacrylate) polymers on hydrophobic and hydrophilic surfaces","volume":"1","author":"Sundaram","year":"2014","unstructured":"Sundaram, H. S. et al. Achieving one-step surface coating of highly hydrophilic poly (carboxybetaine methacrylate) polymers on hydrophobic and hydrophilic surfaces. Adv Mater Interfaces. 1 (6), 1400071 (2014).","journal-title":"Adv Mater Interfaces"},{"issue":"14","key":"ref15","doi-asserted-by":"crossref","first-page":"3209","DOI":"10.1016\/j.polymer.2011.05.008","type":"journal-article","article-title":"Solution spraying of poly (methyl methacrylate) blends to fabricate microtextured, superoleophobic surfaces","volume":"52","author":"Srinivasan","year":"2011","unstructured":"Srinivasan, S., Chhatre, S. S., Mabry, J. M., Cohen, R. E., McKinley, G. H. Solution spraying of poly (methyl methacrylate) blends to fabricate microtextured, superoleophobic surfaces. Polymer. 52 (14), 3209-3218 (2011).","journal-title":"Polymer"},{"issue":"1","key":"ref16","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1021\/nl8037272","type":"journal-article","article-title":"Inherently superoleophobic nanocomposite coatings by spray atomization","volume":"9","author":"Steele","year":"2009","unstructured":"Steele, A., Bayer, I., Loth, E. Inherently superoleophobic nanocomposite coatings by spray atomization. Nano Lett. 9 (1), 501-505 (2009).","journal-title":"Nano Lett"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.actbio.2016.02.036","type":"journal-article","article-title":"Significantly reduced adsorption and activation of blood components in a membrane oxygenator system coated with crosslinkable zwitterionic copolymer","volume":"40","author":"Wang","year":"2016","unstructured":"Wang, Y. B., Shi, K. H., Jiang, H. L., Gong, Y. K. Significantly reduced adsorption and activation of blood components in a membrane oxygenator system coated with crosslinkable zwitterionic copolymer. Acta Biomater. 40, 153-161 (2016).","journal-title":"Acta Biomater"},{"issue":"5","key":"ref18","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1097\/MAT.0000000000000257","type":"journal-article","article-title":"A nitric oxide-releasing self-assembled peptide amphiphile nanomatrix for improving the biocompatibility of microporous hollow fibers","volume":"61","author":"El-Ferzli","year":"2015","unstructured":"El-Ferzli, G. T. et al. A nitric oxide-releasing self-assembled peptide amphiphile nanomatrix for improving the biocompatibility of microporous hollow fibers. Asaio J. 61 (5), 589-595 (2015).","journal-title":"Asaio J"},{"issue":"5","key":"ref19","doi-asserted-by":"crossref","first-page":"1984","DOI":"10.1021\/acs.langmuir.8b03078","type":"journal-article","article-title":"Evaluating the effect of shear stress on graft-to zwitterionic polycarboxybetaine coating stability using a flow cell","volume":"35","author":"Belanger","year":"2018","unstructured":"Belanger, A., Decarmine, A., Jiang, S., Cook, K., Amoako, K. A. Evaluating the effect of shear stress on graft-to zwitterionic polycarboxybetaine coating stability using a flow cell. Langmuir. 35 (5), 1984-1988 (2018).","journal-title":"Langmuir"},{"issue":"36","key":"ref20","doi-asserted-by":"crossref","first-page":"8305","DOI":"10.1039\/D0TB01220C","type":"journal-article","article-title":"A biostable, anti-fouling zwitterionic polyurethane-urea based on PDMS for use in blood-contacting medical devices","volume":"8","author":"Kim","year":"2020","unstructured":"Kim, S. et al. A biostable, anti-fouling zwitterionic polyurethane-urea based on PDMS for use in blood-contacting medical devices. J Mater Chem B. 8 (36), 8305-8314 (2020).","journal-title":"J Mater Chem B"},{"key":"ref21","type":"book","article-title":"Carbonic anhydrase immobilized on hollow fiber membranes using glutaraldehyde activated chitosan for artificial lung applications","volume-title":"J Mater Sci Mater Med","author":"Kimmel","year":"2013","unstructured":"Kimmel, J. D., Arazawa, D. T., Ye, S. H., Shankarraman, V., Wagner, W. R., Federspiel, W. J. Carbonic anhydrase immobilized on hollow fiber membranes using glutaraldehyde activated chitosan for artificial lung applications. J Mater Sci Mater Med. 24, 2611-2621 (2013)."},{"issue":"3","key":"ref22","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.jtcvs.2005.10.050","type":"journal-article","article-title":"Bridge to lung transplantation with the novel pumpless interventional lung assist device NovaLung","volume":"131","author":"Fischer","year":"2006","unstructured":"Fischer, S. et al. Bridge to lung transplantation with the novel pumpless interventional lung assist device NovaLung. J Thorac Cardiovasc Surg. 131 (3), 719-723 (2006).","journal-title":"J Thorac Cardiovasc Surg"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.actbio.2019.05.019","type":"journal-article","article-title":"Zwitterionic poly-carboxybetaine coating reduces artificial lung thrombosis in sheep and rabbits","volume":"92","author":"Ukita","year":"2019","unstructured":"Ukita, R. et al. Zwitterionic poly-carboxybetaine coating reduces artificial lung thrombosis in sheep and rabbits. Acta Biomater. 92, 71-81(2019).","journal-title":"Acta Biomater"},{"issue":"8","key":"ref24","doi-asserted-by":"crossref","first-page":"1400012","DOI":"10.1002\/admi.201400012","type":"journal-article","article-title":"Multi-modal, surface-focused anticoagulation using poly-2-methoxyethylacrylate polymer grafts and surface nitric oxide release","volume":"1","author":"Gupta","year":"2014","unstructured":"Gupta, S., Amoako, K. A., Suhaib, A., Cook, K. E. Multi-modal, surface-focused anticoagulation using poly-2-methoxyethylacrylate polymer grafts and surface nitric oxide release. Adv Mater Interfaces. 1 (8), 1400012 (2014).","journal-title":"Adv Mater Interfaces"},{"issue":"7","key":"ref25","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1002\/jbm.b.33709","type":"journal-article","article-title":"Hemocompatibility and oxygenation performance of polysulfone membranes grafted with polyethylene glycol and heparin by plasma-induced surface modification","volume":"105","author":"Wang","year":"2017","unstructured":"Wang, W. et al. Hemocompatibility and oxygenation performance of polysulfone membranes grafted with polyethylene glycol and heparin by plasma-induced surface modification. J Biomed Mater Res B Appl Biomater. 105 (7), 1737-1746 (2017).","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"459","DOI":"10.4028\/www.scientific.net\/AMR.816-817.459","type":"journal-article","article-title":"Surface modification of polypropylene blood oxygenator membrane by poly ethylene glycol grafting","volume":"816","author":"Abednejad","year":"2013","unstructured":"Abednejad, A. S., Amoabediny, G., Ghaee, A. Surface modification of polypropylene blood oxygenator membrane by poly ethylene glycol grafting. Adv Mater Res. 816, 459-463 (2013).","journal-title":"Adv Mater Res"},{"issue":"4","key":"ref27","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1163\/156856206776374098","type":"journal-article","article-title":"Effect of poly (2-methoxyethyl acrylate)-coated oxygenators on haemolysis","volume":"17","author":"Kocakulak","year":"2006","unstructured":"Kocakulak, M., \u00d6zg\u00fcrta\u015f, T., Ayhan, H. Effect of poly (2-methoxyethyl acrylate)-coated oxygenators on haemolysis. J Biomater Sci Polym Ed. 17 (4), 449-460 (2006).","journal-title":"J Biomater Sci Polym Ed"},{"issue":"2","key":"ref28","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1177\/0267659112469642","type":"journal-article","article-title":"A new phosphorylcholine-coated polymethylpentene oxygenator for extracorporeal membrane oxygenation: a preliminary experience","volume":"28","author":"Pieri","year":"2013","unstructured":"Pieri, M. et al. A new phosphorylcholine-coated polymethylpentene oxygenator for extracorporeal membrane oxygenation: a preliminary experience. Perfusion. 28 (2), 132-137 (2013).","journal-title":"Perfusion"},{"issue":"5","key":"ref29","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1016\/S1010-7940(00)00508-X","type":"journal-article","article-title":"Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface","volume":"18","author":"De Somer","year":"2000","unstructured":"De Somer, F. et al. Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface. Eur J Cardiothorac Surg. 18 (5), 602-606 (2000).","journal-title":"Eur J Cardiothorac Surg"},{"issue":"10","key":"ref30","doi-asserted-by":"crossref","first-page":"4318","DOI":"10.1021\/acs.biomac.2c00775","type":"journal-article","article-title":"Anti-fouling surfaces for extracorporeal membrane oxygenation by surface grafting of hydrophilic sulfoxide polymers","volume":"23","author":"Zhang","year":"2022","unstructured":"Zhang, Y. et al. Anti-fouling surfaces for extracorporeal membrane oxygenation by surface grafting of hydrophilic sulfoxide polymers. Biomacromolecules. 23 (10), 4318-4326 (2022).","journal-title":"Biomacromolecules"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"45","DOI":"10.2147\/PHMT.S35070","type":"journal-article","article-title":"Evolution of membrane oxygenator technology for utilization during pediatric cardiopulmonary bypass","volume":"7","author":"Melchior","year":"2016","unstructured":"Melchior, R. W., Sutton, S. W., Harris, W., Dalton, H. J. Evolution of membrane oxygenator technology for utilization during pediatric cardiopulmonary bypass. Pediatr Health Med Ther. 7, 45-56 (2016).","journal-title":"Pediatr Health Med Ther"},{"issue":"4","key":"ref32","doi-asserted-by":"crossref","first-page":"2200479","DOI":"10.1002\/mabi.202200479","type":"journal-article","article-title":"Zwitterionic polysulfobetaine coating and antiplatelet liposomes reduce fouling in artificial lung circuits","volume":"23","author":"Amoako","year":"2023","unstructured":"Amoako, K. et al. Zwitterionic polysulfobetaine coating and antiplatelet liposomes reduce fouling in artificial lung circuits. Macromol Biosci. 23 (4), 2200479 (2023).","journal-title":"Macromol Biosci"},{"issue":"Supplement 2","key":"ref33","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1097\/01.mat.0000943720.52297.3b","type":"journal-article","article-title":"PULM3: The effects of a two-step coating process and flow on artificial lung fiber fouling","volume":"69","author":"Amoako","year":"2023","unstructured":"Amoako, K. et al. PULM3: The effects of a two-step coating process and flow on artificial lung fiber fouling. Asaio J. 69 (Supplement 2), 88 (2023).","journal-title":"Asaio J"},{"issue":"35","key":"ref34","doi-asserted-by":"crossref","first-page":"12999","DOI":"10.1073\/pnas.0605552103","type":"journal-article","article-title":"Single-molecule mechanics of mussel adhesion","volume":"103","author":"Lee","year":"2006","unstructured":"Lee, H., Scherer, N. F., Messersmith, P. B. Single-molecule mechanics of mussel adhesion. Proc Natl Acad Sci U S A. 103 (35), 12999-13003 (2006).","journal-title":"Proc Natl Acad Sci U S A"},{"issue":"2","key":"ref35","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1021\/bm301844u","type":"journal-article","article-title":"Self-healing mussel-inspired multi-pH-responsive hydrogels","volume":"14","author":"Krogsgaard","year":"2013","unstructured":"Krogsgaard, M., Behrens, M. A., Pedersen, J. S., Birkedal, H. Self-healing mussel-inspired multi-pH-responsive hydrogels. Biomacromolecules. 14 (2), 297-301 (2013).","journal-title":"Biomacromolecules"},{"issue":"7","key":"ref36","doi-asserted-by":"crossref","first-page":"2653","DOI":"10.1021\/bm200464x","type":"journal-article","article-title":"Catechol-functionalized chitosan\/pluronic hydrogels for tissue adhesives and hemostatic materials","volume":"12","author":"Ryu","year":"2011","unstructured":"Ryu, J. H., Lee, Y., Kong, W. H., Kim, T. G., Park, T. G., Lee, H. Catechol-functionalized chitosan\/pluronic hydrogels for tissue adhesives and hemostatic materials. Biomacromolecules. 12 (7), 2653-2659 (2011).","journal-title":"Biomacromolecules"},{"issue":"39","key":"ref37","doi-asserted-by":"crossref","first-page":"eabb7620","DOI":"10.1126\/sciadv.abb7620","type":"journal-article","article-title":"Structure and sequence features of mussel adhesive protein lead to its salt-tolerant adhesion ability","volume":"6","author":"Ou","year":"2020","unstructured":"Ou, X. et al. Structure and sequence features of mussel adhesive protein lead to its salt-tolerant adhesion ability. Sci Adv. 6 (39), eabb7620 (2020).","journal-title":"Sci Adv"},{"issue":"1","key":"ref38","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/MAT.0b013e31815d6898","type":"journal-article","article-title":"Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements","volume":"54","author":"Nobili","year":"2008","unstructured":"Nobili, M., Sheriff, J., Morbiducci, U., Redaelli, A., Bluestein, D. Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements. Asaio J. 54 (1), 64-72 (2008).","journal-title":"Asaio J"},{"issue":"1","key":"ref39","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1177\/0267659110396015","type":"journal-article","article-title":"Hemolysis and ECMO pumps in the 21st century","volume":"26","author":"Toomasian","year":"2011","unstructured":"Toomasian, J. M., Bartlett, R. H. Hemolysis and ECMO pumps in the 21st century. Perfusion. 26 (1), 5 (2011).","journal-title":"Perfusion"},{"issue":"9","key":"ref40","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1002\/adma.200901407","type":"journal-article","article-title":"Ultralow-fouling, functionalizable, and hydrolysable zwitterionic materials and their derivatives for biological applications","volume":"22","author":"Jiang","year":"2010","unstructured":"Jiang, S., Cao, Z. Ultralow-fouling, functionalizable, and hydrolysable zwitterionic materials and their derivatives for biological applications. Adv Mater. 22 (9), 920-932 (2010).","journal-title":"Adv Mater"},{"issue":"5849","key":"ref41","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1126\/science.1147241","type":"journal-article","article-title":"Mussel-inspired surface chemistry for multifunctional coatings","volume":"318","author":"Lee","year":"2007","unstructured":"Lee, H., Dellatore, S. M., Miller, W. M., Messersmith, P. B. Mussel-inspired surface chemistry for multifunctional coatings. Science. 318 (5849), 426-430 (2007).","journal-title":"Science"},{"issue":"4","key":"ref42","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.bsbt.2016.11.001","type":"journal-article","article-title":"Mussel-inspired polydopamine for bio-surface functionalization","volume":"2","author":"Ding","year":"2016","unstructured":"Ding, Y. H., Floren, M., Tan, W. Mussel-inspired polydopamine for bio-surface functionalization. Biosurface Biotribology. 2 (4), 121-136 (2016).","journal-title":"Biosurface Biotribology"},{"issue":"12","key":"ref43","doi-asserted-by":"crossref","first-page":"4916","DOI":"10.1039\/c1nr10969c","type":"journal-article","article-title":"Polydopamine-a nature-inspired polymer coating for biomedical science","volume":"3","author":"Lynge","year":"2011","unstructured":"Lynge, M. E., van der Westen, R., Postma, A., St\u00e4dler, B. Polydopamine-a nature-inspired polymer coating for biomedical science. Nanoscale. 3 (12), 4916-4928 (2011).","journal-title":"Nanoscale"},{"issue":"6","key":"ref44","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1016\/j.ejcts.2008.09.001","type":"journal-article","article-title":"Early experience with the Levitronix Centrimag\u00ae device for extra-corporeal membrane oxygenation following lung transplantation","volume":"34","author":"Khan","year":"2008","unstructured":"Khan, N. U., Al-Aloul, M., Shah, R., Yonan, N. Early experience with the Levitronix Centrimag\u00ae device for extra-corporeal membrane oxygenation following lung transplantation. Eur J Cardiothorac Surg. 34 (6), 1262-1264 (2008).","journal-title":"Eur J Cardiothorac Surg"},{"issue":"2","key":"ref45","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/MAT.0000000000000314","type":"journal-article","article-title":"Clinical durability of the CARMEDA bioactive surface in EXCOR ventricular assist device pumps","volume":"62","author":"Werkkala","year":"2016","unstructured":"Werkkala, K. et al. Clinical durability of the CARMEDA bioactive surface in EXCOR ventricular assist device pumps. Asaio J. 62 (2), 139-142 (2016).","journal-title":"Asaio J"},{"issue":"3","key":"ref46","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1177\/026765919801300307","type":"journal-article","article-title":"Heparin-bonded circuits: clinical outcomes and costs","volume":"13","author":"Mahoney","year":"1998","unstructured":"Mahoney, C. B. Heparin-bonded circuits: clinical outcomes and costs. Perfusion. 13 (3), 192-204 (1998).","journal-title":"Perfusion"},{"issue":"2","key":"ref47","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1067\/mtc.2001.111655","type":"journal-article","article-title":"Heparin antibodies and thromboembolism in heparin-coated and noncoated ventricular assist devices","volume":"121","author":"Koster","year":"2001","unstructured":"Koster, A. et al. Heparin antibodies and thromboembolism in heparin-coated and noncoated ventricular assist devices. J Thorac Cardiovasc Surg. 121 (2), 331-335 (2001).","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"1","key":"ref48","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1177\/026765919901400104","type":"journal-article","article-title":"Haemocompatibility of paediatric membrane oxygenators with heparin-coated surfaces","volume":"14","author":"Wendel","year":"1999","unstructured":"Wendel, H. P., Scheule, A. M., Eckstein, F. S., Ziemer, G. Haemocompatibility of paediatric membrane oxygenators with heparin-coated surfaces. Perfusion. 14 (1), 21-28 (1999).","journal-title":"Perfusion"},{"issue":"3","key":"ref49","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1051\/ject\/199224397","type":"journal-article","article-title":"The effects of heparin bound surface modification (Carmeda\u00ae Bioactive Surface) on human platelet alterations during simulated extracorporeal circulation","volume":"24","author":"Stenach","year":"1992","unstructured":"Stenach, N., Korn, R. L., Fisher, C. A., Jeevanandam, V., Addonizio, V. P. The effects of heparin bound surface modification (Carmeda\u00ae Bioactive Surface) on human platelet alterations during simulated extracorporeal circulation. J Extracorporeal Technol. 24 (3), 97-102 (1992).","journal-title":"J Extracorporeal Technol"},{"issue":"5","key":"ref50","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1016\/S0022-5223(96)70384-7","type":"journal-article","article-title":"The effects of Carmeda Bioactive Surface on human blood components during simulated extracorporeal circulation","volume":"111","author":"Korn","year":"1996","unstructured":"Korn, R. L. et al. The effects of Carmeda Bioactive Surface on human blood components during simulated extracorporeal circulation. J Thorac Cardiovasc Surg. 111 (5), 1073-1084 (1996).","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"5","key":"ref51","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1097\/00001721-199410000-00001","type":"journal-article","article-title":"Heparin-coated oxygenators significantly reduce contact system activation in an in vitro cardiopulmonary bypass model","volume":"5","author":"Wendel","year":"1994","unstructured":"Wendel, H. P., Heller, W., Gallimore, M. J., Hoffmeister, H. E. Heparin-coated oxygenators significantly reduce contact system activation in an in vitro cardiopulmonary bypass model. Blood Coagul Fibrinolysis. 5 (5), 673-678 (1994).","journal-title":"Blood Coagul Fibrinolysis"},{"issue":"11","key":"ref52","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1295\/polymj.24.1259","type":"journal-article","article-title":"Preparation of 2-methacryloyloxyethyl phosphorylcholine copolymers with alkyl methacrylates and their blood compatibility","volume":"24","author":"Ueda","year":"1992","unstructured":"Ueda, T., Oshida, H., Kurita, K., Ishihara, K., Nakabayashi, N. Preparation of 2-methacryloyloxyethyl phosphorylcholine copolymers with alkyl methacrylates and their blood compatibility. Polym J. 24 (11), 1259-1269 (1992).","journal-title":"Polym J"},{"issue":"3","key":"ref53","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1051\/ject\/201042199","type":"journal-article","article-title":"Modified surface coatings and their effect on drug adsorption within the extracorporeal life support circuit","volume":"42","author":"Preston","year":"2010","unstructured":"Preston, T. J. et al. Modified surface coatings and their effect on drug adsorption within the extracorporeal life support circuit. J Extracorporeal Technol. 42 (3), 199-202 (2010).","journal-title":"J Extracorporeal Technol"},{"issue":"6","key":"ref54","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1177\/0267659112454558","type":"journal-article","article-title":"Retrospective analysis of outcome data with regards to the use of Phisio\u00ae-, Bioline\u00ae-or Softline\u00ae-coated cardiopulmonary bypass circuits in cardiac surgery","volume":"27","author":"Reser","year":"2012","unstructured":"Reser, D. et al. Retrospective analysis of outcome data with regards to the use of Phisio\u00ae-, Bioline\u00ae-or Softline\u00ae-coated cardiopulmonary bypass circuits in cardiac surgery. Perfusion. 27 (6), 530-534 (2012).","journal-title":"Perfusion"},{"issue":"1","key":"ref55","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1051\/ject\/200638027","type":"journal-article","article-title":"In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass","volume":"38","author":"Ask","year":"2006","unstructured":"Ask, A., Holt, D., Smith, L. In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass. J Extracorporeal Technol. 38 (1), 27-32 (2006).","journal-title":"J Extracorporeal Technol"},{"issue":"3","key":"ref56","doi-asserted-by":"crossref","first-page":"M399","DOI":"10.1097\/00002480-199207000-00064","type":"journal-article","article-title":"Plasma leakage through microporous membranes: Role of phospholipids","volume":"38","author":"Montoya","year":"1992","unstructured":"Montoya, J. P., Shanley, C. J., Merz, S. I., Bartlett, R. H. Plasma leakage through microporous membranes: Role of phospholipids. Asaio J. 38 (3), M399-M405 (1992).","journal-title":"Asaio J"},{"issue":"3","key":"ref57","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1177\/039139889601900307","type":"journal-article","article-title":"Small pore size microporous membrane oxygenator reduces plasma leakage during prolonged extracorporeal circulation: a case report","volume":"19","author":"Musch","year":"1996","unstructured":"Musch, G. et al. Small pore size microporous membrane oxygenator reduces plasma leakage during prolonged extracorporeal circulation: a case report. Int J Artif Organs. 19 (3), 177-180 (1996).","journal-title":"Int J Artif Organs"},{"issue":"3","key":"ref58","first-page":"640","type":"journal-article","article-title":"Technical aspects of plasma leakage prevention in microporous capillary membrane oxygenators","volume":"35","author":"Mottaghy","year":"1989","unstructured":"Mottaghy, K. et al. Technical aspects of plasma leakage prevention in microporous capillary membrane oxygenators. Asaio J. 35 (3), 640-643 (1989).","journal-title":"Asaio J"},{"issue":"Suppl. 1","key":"ref59","type":"journal-article","article-title":"Breaking bad news in the emergency department: a randomized controlled study of a training using role-play simulation","volume":"22","author":"Bragard","year":"2018","unstructured":"Bragard, I. et al. Breaking bad news in the emergency department: a randomized controlled study of a training using role-play simulation. Crit Care. 22 (Suppl. 1) (2018).","journal-title":"Crit Care"},{"issue":"8","key":"ref60","doi-asserted-by":"crossref","first-page":"2700","DOI":"10.1053\/j.jvca.2021.11.006","type":"journal-article","article-title":"ECMO in COVID-19 patients: a systematic review and meta-analysis","volume":"36","author":"Bertini","year":"2022","unstructured":"Bertini, P. et al. ECMO in COVID-19 patients: a systematic review and meta-analysis. J Cardiothorac Vasc Anesth. 36 (8), 2700-2706 (2022).","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"1","key":"ref61","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/s40560-023-00654-7","type":"journal-article","article-title":"Extracorporeal membrane oxygenation for COVID-19-related acute respiratory distress syndrome: a narrative review","volume":"11","author":"Alessandri","year":"2023","unstructured":"Alessandri, F., Di Nardo, M., Ramanathan, K., Brodie, D., MacLaren, G. Extracorporeal membrane oxygenation for COVID-19-related acute respiratory distress syndrome: a narrative review. J Intensive Care. 11 (1), 5 (2023).","journal-title":"J Intensive Care"},{"issue":"1","key":"ref62","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1146\/annurev.bi.53.070184.001211","type":"journal-article","article-title":"Fibrinogen and fibrin","volume":"53","author":"Doolittle","year":"1984","unstructured":"Doolittle, R. F. Fibrinogen and fibrin. Annu Rev Biochem. 53 (1), 195-229 (1984).","journal-title":"Annu Rev Biochem"}],"container-title":["Journal of Visualized Experiments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/app.jove.com\/t\/67271\/artificial-lung-device-priming-for-situ-fiber-bundle-surface","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T15:34:18Z","timestamp":1792596858000},"score":1,"resource":{"primary":{"URL":"https:\/\/app.jove.com\/t\/67271\/artificial-lung-device-priming-for-situ-fiber-bundle-surface"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,28]]},"references-count":62,"journal-issue":{"issue":"217","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.3791\/67271","relation":{},"ISSN":["1940-087X"],"issn-type":[{"value":"1940-087X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,28]]}}}