{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T20:03:27Z","timestamp":1791576207440,"version":"4.3.4"},"reference-count":41,"publisher":"Spandidos Publications","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Exp Ther Med"],"DOI":"10.3892\/etm.2024.12579","type":"journal-article","created":{"date-parts":[[2024,5,21]],"date-time":"2024-05-21T11:33:29Z","timestamp":1716291209000},"source":"Crossref","is-referenced-by-count":11,"title":["Application of 3D\u2011printed porous titanium interbody fusion cage vs. polyether ether ketone interbody fusion cage in anterior cervical discectomy and fusion: A systematic review and meta\u2011analysis update"],"prefix":"10.3892","volume":"28","author":[{"given":"Wan-Jing","family":"Zhai","sequence":"first","affiliation":[{"name":"Graduate School, The First Clinical College of Changzhi Medical College, Changzhi, Shanxi 046000, P.R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lun","family":"Liu","sequence":"additional","affiliation":[{"name":"Graduate School, The First Clinical College of Changzhi Medical College, Changzhi, Shanxi 046000, P.R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu-Hao","family":"Gao","sequence":"additional","affiliation":[{"name":"Graduate School, The First Clinical College of Changzhi Medical College, Changzhi, Shanxi 046000, P.R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shi-Lei","family":"Qin","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Changzhi Yunfeng Hospital, Changzhi, Shanxi 046000, P.R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng-Fei","family":"Han","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Heping Hospital Affiliated to Changzhi Medical College, Changzhi, Shanxi 046000, P.R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun-Feng","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Changzhi Yunfeng Hospital, Changzhi, Shanxi 046000, P.R. China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2249","published-online":{"date-parts":[[2024,5,21]]},"reference":[{"issue":"47","key":"key20240618110521_b1-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-022-02940-w","article-title":"Comparison of outcomes between Zero-p implant and anterior cervical plate interbody fusion systems for anterior cervical decompression and fusion: A systematic review and meta-analysis of randomized controlled trials","volume":"17","author":"Zhang","year":"2022","journal-title":"J Orthop Surg Res"},{"issue":"108","key":"key20240618110521_b2-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-018-0822-1","article-title":"Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting","volume":"13","author":"Schmitz","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"key20240618110521_b3-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.1016\/j.spinee.2018.02.017","article-title":"The in vivo response to a novel Ti coating compared with polyether ether ketone: Evaluation of the periphery and inner surfaces of an implant","volume":"18","author":"Walsh","year":"2018","journal-title":"Spine J"},{"key":"key20240618110521_b4-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.wneu.2020.03.130","article-title":"Incidence of subsidence of seven intervertebral devices in anterior cervical discectomy and fusion: A network meta-analysis","volume":"141","author":"Xu","year":"2020","journal-title":"World Neurosurg"},{"key":"key20240618110521_b5-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"757","DOI":"10.21037\/jss.2018.12.01","article-title":"3-dimensional printing for anterior cervical surgery: A review","volume":"4","author":"Choy","year":"2018","journal-title":"J Spine Surg"},{"key":"key20240618110521_b6-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1177\/11207000221135068","article-title":"Custom designed and 3D-printed titanium pelvic implants for acetabular reconstruction after tumour resection","volume":"33","author":"Broekhuis","year":"2023","journal-title":"Hip Int"},{"issue":"e928022","key":"key20240618110521_b7-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.12659\/MSM.928022","article-title":"Comparative analysis of 3D-printed artificial vertebral body versus titanium mesh cage in repairing bone defects following single-level anterior cervical corpectomy and fusion","volume":"27","author":"Fang","year":"2021","journal-title":"Med Sci Monit"},{"issue":"521","key":"key20240618110521_b8-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-023-03986-0","article-title":"Standardized 3D-printed trabecular titanium augment and cup for acetabular bone defects in revision hip arthroplasty: A mid-term follow-up study","volume":"18","author":"Hao","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"key20240618110521_b9-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1097\/BSD.0000000000001469","article-title":"3D-printed titanium prosthetic reconstruction of unilateral bone deficiency after surgical resection of tumor lesions in the upper cervical spine: Clinical outcomes of three consecutive cases and narrative review","volume":"36","author":"Shen","year":"2023","journal-title":"Clin Spine Surg"},{"key":"key20240618110521_b10-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/j.spinee.2020.03.008","article-title":"Porous titanium cervical interbody fusion device in the treatment of degenerative cervical radiculopathy; 1-year results of a prospective controlled trial","volume":"20","author":"Arts","year":"2020","journal-title":"Spine J"},{"key":"key20240618110521_b11-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1371\/journal.pmed.1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement","volume":"62","author":"Moher","year":"2009","journal-title":"J Clin Epidemiol"},{"issue":"E6","key":"key20240618110521_b12-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.3171\/2016.3.FOCUS1648","article-title":"Psychometric analysis and critical appraisal of the original, revised, and modified versions of the Japanese Orthopaedic Association score in the assessment of patients with cervical spondylotic myelopathy","volume":"40","author":"Furlan","year":"2016","journal-title":"Neurosurg Focus"},{"key":"key20240618110521_b13-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1017\/s0033291700009934","article-title":"Clinical applications of visual analogue scales: A critical review","volume":"18","author":"McCormack","year":"1988","journal-title":"Psychol Med"},{"issue":"d5928","key":"key20240618110521_b14-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d5928","article-title":"The cochrane collaboration's tool for assessing risk of bias in randomised trials","volume":"343","author":"Higgins","year":"2011","journal-title":"BMJ"},{"key":"key20240618110521_b15-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10654-010-9491-z","article-title":"Critical evaluation of the newcastle-ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses","volume":"25","author":"Stang","year":"2010","journal-title":"Eur J Epidemiol"},{"key":"key20240618110521_b16-ETM-28-1-12579","first-page":"236","article-title":"Early clinical study on anterior cervical fusion surgery with 3D printed interbody fusion cage for treatment of cervical disk herniation","volume":"24","author":"Bai","year":"2023","journal-title":"J Nat Sci"},{"key":"key20240618110521_b17-ETM-28-1-12579","first-page":"2837","article-title":"Efficacy of 3D printed microporous titanium fusion device applied to anterior cervical decompression graft fusion and its effects on cervical spine anatomy and stress hormones","volume":"27","author":"Jiang","year":"2023","journal-title":"Chin J Tissue Eng Res"},{"key":"key20240618110521_b18-ETM-28-1-12579","author":"Li"},{"key":"key20240618110521_b19-ETM-28-1-12579","first-page":"16","article-title":"Comparison of the efficacy of ACDF in the treatment of cervical spondylotic myelopathy using 3D printed intervertebral fusion cage and Polyether-ether-ketone (PEEK) intervertebral fusion cage","volume":"31","author":"Li","year":"2021","journal-title":"Chin J Spine and Spinal Cord"},{"key":"key20240618110521_b20-ETM-28-1-12579","first-page":"849","article-title":"Application of 3D printed interbody fusion cage for cervical spondylosis of spinal cord type: Half-year follow-up of recovery of cervical curvature and intervertebral height","volume":"25","author":"Liu","year":"2021","journal-title":"Chin J Tissue Eng Res"},{"key":"key20240618110521_b21-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.7507\/1002-1892.202103003","article-title":"Effectiveness of three-dimensional printing artificial vertebral body and interbody fusion Cage in anterior cervical surgery","volume":"35","author":"Wang","year":"2021","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"key":"key20240618110521_b22-ETM-28-1-12579","first-page":"342","article-title":"Follow-up of the clinical efficacy and sagittal balance of 3D printing spine intervertebral fusion cage in treatment of cervical spondylosis","volume":"41","author":"Wang","year":"2023","journal-title":"Chin J Clin Anat"},{"key":"key20240618110521_b23-ETM-28-1-12579","first-page":"1","article-title":"Application of 3D print porous titanium alloy intervertebral fusion cage in anterior cervical discectomy and bone graft fusion for treatment of cervical spondylopathy","volume":"38","author":"Wang","year":"2023","journal-title":"Chin J Bone and Joint Inj"},{"key":"key20240618110521_b24-ETM-28-1-12579","first-page":"5741","article-title":"Changes in cervical sagittal balance after three-dimensional printing ACT titanium cage in anterior cervical discectomy with fusion","volume":"24","author":"Yang","year":"2020","journal-title":"Chin J Tissue Eng Res"},{"key":"key20240618110521_b25-ETM-28-1-12579","first-page":"97","article-title":"Clinical efficacy of 3D-printed titanium cage in the treatment of cervical spondylotic myelopathy and changes in cervical sagittal parameter","volume":"12","author":"Zhang","year":"2021","journal-title":"Orthopaedics"},{"key":"key20240618110521_b26-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"446","DOI":"10.4184\/asj.2018.12.3.446","article-title":"Combined laminoplasty and posterior fusion for cervical spondylotic myelopathy treatment: A literature review","volume":"12","author":"Bridges","year":"2018","journal-title":"Asian Spine J"},{"issue":"46","key":"key20240618110521_b27-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.3390\/biomimetics7020046","article-title":"A review of biomimetic topographies and their role in promoting bone formation and osseointegration: Implications for clinical use","volume":"7","author":"Berger","year":"2022","journal-title":"Biomimetics (Basel)"},{"key":"key20240618110521_b28-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"27503","DOI":"10.1021\/acsami.9b03030","article-title":"Facile surface modification method for synergistically enhancing the biocompatibility and bioactivity of poly(ether ether ketone) that induced osteodifferentiation","volume":"11","author":"Zhu","year":"2019","journal-title":"ACS Appl Mater Interfaces"},{"key":"key20240618110521_b29-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/j.jos.2019.01.015","article-title":"Progress in biological reconstruction and enhanced bone revitalization for bone defects","volume":"24","author":"Yamamoto","year":"2019","journal-title":"J Orthop Sci"},{"key":"key20240618110521_b30-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"844","DOI":"10.1016\/j.msec.2019.04.064","article-title":"Review on titanium and titanium based alloys as biomaterials for orthopaedic applications","volume":"102","author":"Kaur","year":"2019","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"issue":"e06892","key":"key20240618110521_b31-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2021.e06892","article-title":"Additive manufacturing of Ti6Al4V alloy via electron beam melting for the development of implants for the biomedical industry","volume":"7","author":"Tamayo","year":"2021","journal-title":"Heliyon"},{"issue":"105","key":"key20240618110521_b32-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-018-2027-5","article-title":"Quantitative analysis of near-implant magnesium accumulation for a Si-containing coated AZ31 cage from a goat cervical spine fusion model","volume":"19","author":"Zhang","year":"2018","journal-title":"BMC Musculoskelet Disord"},{"key":"key20240618110521_b33-ETM-28-1-12579","author":"Li"},{"key":"key20240618110521_b34-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1016\/j.spinee.2022.01.003","article-title":"Subsidence and fusion performance of a 3D-printed porous interbody cage with stress-optimized body lattice and microporous endplates-a comprehensive mechanical and biological analysis","volume":"22","author":"Fogel","year":"2022","journal-title":"Spine J"},{"key":"key20240618110521_b35-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"1969","DOI":"10.1111\/os.13005","article-title":"Mid- and long-term follow-up efficacy analysis of 3D-printed interbody fusion cages for anterior cervical discectomy and fusion","volume":"13","author":"Jin","year":"2021","journal-title":"Orthop Surg"},{"key":"key20240618110521_b36-ETM-28-1-12579","first-page":"34","article-title":"3D-printed porous titanium cage versus polyetheretherketone cage in sheep vertebral fusion","volume":"17","author":"Li","year":"2015","journal-title":"Chin J Orthop Trauma"},{"key":"key20240618110521_b37-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"E191","DOI":"10.1111\/aor.12153","article-title":"Porous titanium-6 aluminum-4 vanadium cage has better osseointegration and less micromotion than a poly-ether-ether-ketone cage in sheep vertebral fusion","volume":"37","author":"Wu","year":"2013","journal-title":"Artif Organs"},{"key":"key20240618110521_b38-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1007\/s00701-019-04139-1","article-title":"Radiographic measurements of cervical alignment, fusion and subsidence after ACDF surgery and their impact on clinical outcome","volume":"162","author":"Obermueller","year":"2020","journal-title":"Acta Neurochir (Wien)"},{"key":"key20240618110521_b39-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.actbio.2015.11.013","article-title":"3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface","volume":"30","author":"Shah","year":"2016","journal-title":"Acta Biomater"},{"issue":"888","key":"key20240618110521_b40-ETM-28-1-12579","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-023-04393-1","article-title":"Comparing the efficacy of unilateral biportal endoscopic transforaminal lumbar interbody fusion and minimally invasive transforaminal lumbar interbody fusion in lumbar degenerative diseases: A systematic review and meta-analysis","volume":"18","author":"Luan","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"key20240618110521_b41-ETM-28-1-12579","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.spinee.2022.10.005","article-title":"Patients with radiculopathy have worse baseline disability and greater improvements following anterior cervical discectomy and fusion compared to patients with myelopathy","volume":"23","author":"Toci","year":"2023","journal-title":"Spine J"}],"container-title":["Experimental and Therapeutic Medicine"],"original-title":[],"deposited":{"date-parts":[[2024,6,18]],"date-time":"2024-06-18T08:11:13Z","timestamp":1718698273000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.spandidos-publications.com\/10.3892\/etm.2024.12579"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,21]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,5,21]]}},"URL":"https:\/\/doi.org\/10.3892\/etm.2024.12579","relation":{},"ISSN":["1792-0981","1792-1015"],"issn-type":[{"value":"1792-0981","type":"print"},{"value":"1792-1015","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,21]]},"article-number":"290"}}