{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T07:47:24Z","timestamp":1787903244735,"version":"build-2784847793"},"reference-count":56,"publisher":"Korean Association of Internal Medicine","issue":"1","license":[{"start":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T00:00:00Z","timestamp":1714694400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/3.0\/"}],"content-domain":{"domain":["kjim.org"],"crossmark-restriction":true},"short-container-title":["Korean J Intern Med"],"published-print":{"date-parts":[[2025,1,1]]},"abstract":"<jats:p>In recent years, the development and use of various devices for the screening of atrial fibrillation (AF) have significantly increased. Such devices include 12-lead electrocardiogram (ECG), photoplethysmography systems, and single-lead ECG and ECG patches. This review outlines several studies that have focused on the feasibility and efficacy of such devices for AF screening, and summarizes the risks and benefits involved in the initiation of anticoagulant therapy after early detection of AF. We also describe several ongoing trials on unresolved issues associated with AF screening. Overall, this review provides a comprehensive summary of the current state of AF screening and its implications for patient care.<\/jats:p>","DOI":"10.3904\/kjim.2023.521","type":"journal-article","created":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T08:02:13Z","timestamp":1714723333000},"page":"7-14","update-policy":"https:\/\/doi.org\/10.3904\/crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Screening and diagnosis of atrial fibrillation using wearable devices"],"prefix":"10.3904","volume":"40","author":[{"given":"Yoon Jung","family":"Park","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7677-4895","authenticated-orcid":true,"given":"Myung Hwan","family":"Bae","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2270","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2018.04.017"},{"key":"ref2","first-page":"373","volume-title":"2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the Europea","author":"Hindricks","year":"2021"},{"key":"ref3","first-page":"392","volume-title":"Atrial fibrillation and dementia: a report from the AF-SCREEN International Collaboration","author":"Rivard","year":"2022"},{"key":"ref4","first-page":"e56","volume-title":"Heart disease and stroke statistics-2019 update: a report from the American Heart Association","author":"Benjamin","year":"2019"},{"key":"ref5","first-page":"e364","volume-title":"2021 guideline for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline from the American Heart Association\/American Stroke Association","author":"Kleindorfer","year":"2021"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(13)62343-0"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-146-12-200706190-00007"},{"key":"ref8","first-page":"2197","volume-title":"Global survey of the frequency of atrial fibrillation-associated stroke: embolic stroke of undetermined source global registry","author":"Perera","year":"2016"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/s1474-4422(15)70027-x"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1159\/000457809"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2018.8102"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.117.030583"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.121.057014"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(21)01637-8"},{"key":"ref15","first-page":"1523","volume-title":"Mobile health technology to improve care for patients with atrial fibrillation","author":"Guo","year":"2020"},{"key":"ref16","first-page":"360","volume-title":"Screening for atrial fibrillation: US Preventive Services Task Force recommendation statement","author":"Davidson","year":"2022"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.hlc.2018.06.1043"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1001\/jamacardio.2018.4335"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1001\/jamacardio.2018.0136"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1161\/circresaha.119.316342"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1161\/circresaha.120.316341"},{"key":"ref22","first-page":"1741","volume-title":"Ambulatory external electrocardiographic monitoring: focus on atrial fibrillation","author":"Mittal","year":"2011"},{"key":"ref23","first-page":"1582","volume-title":"Wearable devices for ambulatory cardiac monitoring: JACC state-of-the-art review","author":"Sana","year":"2020"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2021.10.021"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.3109\/14017431.2012.661873"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.3390\/s18061714"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.4068\/cmj.2021.57.1.1"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1038\/s41569-021-00522-7"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.122.060291"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa1901183"},{"key":"ref31","first-page":"2365","volume-title":"Mobile photoplethysmographic technology to detect atrial fibrillation","author":"Guo","year":"2019"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.3390\/s19204377"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.7326\/m19-2018"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1160\/th14-03-0231"},{"key":"ref35","first-page":"285","volume-title":"Feasibility of extended ambulatory electrocardiogram monitoring to identify silent atrial fibrillation in high-risk patients: the Screening Study for Undiagnosed Atrial Fibrillation (STUDY-AF)","author":"Turakhia","year":"2015"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.3390\/s21093122"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1001\/jamacardio.2021.0038"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2007.00693.x"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.121.058911"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1056\/nejme2311558"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejim.2022.06.023"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa1105575"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehx042"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.119.041303"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euw279"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(21)01698-6"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa2303062"},{"key":"ref48","first-page":"107","volume-title":"Apixaban for stroke prevention in subclinical atrial fibrillation","author":"Healey","year":"2024"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehac547"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1001\/jamahealthforum.2022.2419"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2020.09.001"},{"key":"ref52","doi-asserted-by":"publisher","DOI":"10.1161\/circulationaha.120.047633"},{"key":"ref53","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2022.04.005"},{"key":"ref54","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2023.01.004"},{"key":"ref55","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.79.1.50"},{"key":"ref56","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.39280.660567.55"}],"container-title":["The Korean Journal of Internal Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/kjim.org\/upload\/kjim-2023-521.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/kjim.org\/journal\/view.php?doi=10.3904\/kjim.2023.521","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/kjim.org\/upload\/kjim-2023-521.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,7]],"date-time":"2025-01-07T01:13:30Z","timestamp":1736212410000},"score":1,"resource":{"primary":{"URL":"http:\/\/kjim.org\/journal\/view.php?doi=10.3904\/kjim.2023.521"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,1]]},"references-count":56,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"URL":"https:\/\/doi.org\/10.3904\/kjim.2023.521","relation":{},"ISSN":["1226-3303","2005-6648"],"issn-type":[{"value":"1226-3303","type":"print"},{"value":"2005-6648","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,1]]},"assertion":[{"value":"2023-11-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-01-06","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-05-03","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-01","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}