{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T22:53:30Z","timestamp":1772837610207,"version":"3.50.1"},"reference-count":18,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[1988,5]]},"abstract":"<jats:p>ABSTRACT: Radiographic changes occurring beneath three types of non-cemented, porous coated, cobalt-chrome tibial components were retrospectively reviewed a minimum of 1 year after arthroplasty. Radiolucent zones, radiodense lines, and loose sintered particles were commonly observed. These changes are consistent with non-rigid, fibrous tissue fixation. Histologic evaluation of two specimens retrieved at revision surgery revealed predominantly fibrous tissue within the porous surface under the tibial plateau. The long-term implication of fibrous tissue fixation of porous coated tibial implants in unknown.<\/jats:p>","DOI":"10.3928\/0147-7447-19880501-10","type":"journal-article","created":{"date-parts":[[2021,4,21]],"date-time":"2021-04-21T22:40:26Z","timestamp":1619044826000},"page":"725-731","source":"Crossref","is-referenced-by-count":17,"title":["Radiographic and Histologic Study of Porous Coated Tibial Component Fixation in Cementless Total Knee Arthroplasty"],"prefix":"10.3928","volume":"11","author":[{"given":"Gerard A","family":"Engh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J D","family":"Bobyn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tracy L","family":"Petersen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1 . Bryan RS Rand JA: Revision total knee arthroplasty. Clin Orthop 1982; 170:116.","DOI":"10.1097\/00003086-198210000-00015"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Pilliar RM: Powder metal-made orthopedic implants with porous surface for fixation by tissue ingrowth. Clin Orthop 1983; 176:42-51.","DOI":"10.1097\/00003086-198306000-00007"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Bobyn JD Engh CA: Human histology of the boneporous metal implant interface. Orthopedics 1984; 7:1410-1421.","DOI":"10.3928\/0147-7447-19840901-05"},{"key":"e_1_3_1_5_1","unstructured":"4. Engh CA Bobyn JD: Biological Fixation in Total Hip Arthroplasty. Thorofare NJ Slack 1985. ? 191."},{"key":"e_1_3_1_6_1","unstructured":"5. Rand JA Bryan RS Chao EYS et al: A comparison of cemented versus cementless porous-coated anatomic total knee arthroplasty in Rand JR Dorr LD (eds): Proceedings qfthe Knee Society. Rockvilie MD. Aspen. 1987. pp 195-212."},{"key":"e_1_3_1_7_1","unstructured":"6. Stulberg SD Stulberg BN: The biological response to uncemented total knee replacements in Rand JR Dorr LD (eds): Proceedings qfthe Knee Society. Rockvilie MD Aspen. 1987. pp 143-172."},{"key":"e_1_3_1_8_1","unstructured":"7. Magee FP Weinstein AM: The effect of position on me detection of radiolucent lines beneath the tibial tray. Transactions of the 32nd Annual ORS Meeting New Orleans Louisiana 1986 ? 357."},{"key":"e_1_3_1_9_1","unstructured":"8. Collier JP Mayor MB. Townley CO et al: Histology of retrieved porous-coated knee prostheses. Proceedings of 53rd AAOS. New Orleans Louisiana 1986 ? 41."},{"key":"e_1_3_1_10_1","unstructured":"9. Haddad RJ Cook SD Thomas KA et al: Histologic and microradiographic analysis of noncemeted retrieved PCA knee components. Proceedings of 53rd AAOS New Orleans Louisiana 1986 ? 41."},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Tibrewal SB Grant KA Goodfellow JW: The radiolucent line beneath the tibial components of the Oxford meniscal knee. J Bone Joint Surg 1984; 66B:523.","DOI":"10.1302\/0301-620X.66B4.6746686"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Engh CA Bobyn JD Glassman AH: Porous coated hip replacement. The factors governing bone ingrowth stress shielding and clinical results. J Bone Joint Surg 1987; 69B:45-55.","DOI":"10.1302\/0301-620X.69B1.3818732"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Ring PA: Uncemented surface replacement of the knee joint. Clin Orthop 1980; 148:106.","DOI":"10.1097\/00003086-198005000-00015"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13 . Blaha JD lnsler HP Freeman MAR et al: The fixation of a proximal tibial polyethylene prosthesis without cement. J Bone Joint Surg 1982; 64B:326.","DOI":"10.1302\/0301-620X.64B3.7096399"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Cameron HU Pilliar RM MacNab 1: The effect of movement of the bonding of porous metal to bone. J Biomed Mater Res 1973; 7:301.","DOI":"10.1002\/jbm.820070404"},{"key":"e_1_3_1_16_1","unstructured":"15. Kenna RV Hungerford DS: Design rationale for the porous coated anatomic total knee system in Hungerford DS. Krakow KA Kenna RV (eds): Total Knee Arthroplasty. A Comprehensive Approach. Baltimore Williams and Wilkins 1984."},{"key":"e_1_3_1_17_1","unstructured":"16. Postak PD Matejczyk MB Greenwald AS: Stability characteristics of total knee replacements. Scientific Exhibit. 54th Annual Meeting of the AAOS San Francisco 1987."},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Rosenqvist R Bylander B Knutson K et al: Loosening of the porous coating of bicompartmental prostheses in patients with rheumatoid arthritis. J Bone Joint Surg 1986; 68A:538-542.","DOI":"10.2106\/00004623-198668040-00009"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Buchert PK Vaughn BK. Mallory TH et al: Excessive metal release due to loosening and fretting of sintered particles on porous-coated hip prostheses. Report of two cases. J Bone Joint Surg 1986; 68A:606-609.","DOI":"10.2106\/00004623-198668040-00020"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T07:59:26Z","timestamp":1683100766000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-19880501-10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1988,5]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1988,5]]}},"alternative-id":["10.3928\/0147-7447-19880501-10"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-19880501-10","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[1988,5]]}}}