{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T12:06:49Z","timestamp":1747138009033},"reference-count":10,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[1990,3]]},"abstract":"<jats:p>ABSTRACT: Twelve patients with complex fractures of the distal radius were treated with the Orthofix external fixation system (EBI Medical Systems, Fairfield, NJ). On follow up physical examination, the average wrist dorsiflexion was 46 degrees, and the average volar flexion was 55 degrees. The average grip strength in the involved hand was 38 lb force. The average final radial angle was 18 degrees, and the average residual radial height was 12 mm. Average volar tilt was 3 degrees. The complication rate was 42%. Very rigid axial stability is afforded by the fixator, but the large 3.5 mm tapered bone screw diameter precludes redrilling for screw adjustment. The apparatus needs frequent monitoring to reconfirm the security of the locking nuts and cam mechanisms, and the Orthofix system can be reused only four times.<\/jats:p>","DOI":"10.3928\/0147-7447-19900301-12","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T02:56:39Z","timestamp":1619060199000},"page":"329-333","source":"Crossref","is-referenced-by-count":6,"title":["Early Clinical Experience With Orthofix External Fixation of Complex Distal Radius Fractures"],"prefix":"10.3928","volume":"13","author":[{"given":"Barry J","family":"Gainor","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gordon I","family":"Groh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","unstructured":"1. Palmer AK. Fractures of the distal radius. In: Green DP ed. Operative Hand Surgery. New York: Churchill Livingstone; 1988:9911026."},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Nakata RY. Chand Y. Matiko JD Frykman GK Wood VE. External fixators for wrist fractures: A biomechanical and clinic study. J Hand Surg. 1985; 10A:845-851.","DOI":"10.1016\/S0363-5023(85)80160-X"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. DeBastiani G Aldegheri R Brivio LR. Dynamic axial fixation a rational alternative for the external fixation of fractures lnt Orthop. 1986; 10:95-99.","DOI":"10.1007\/BF00267748"},{"key":"e_1_3_1_5_1","unstructured":"4. Songer IE Kendra JC Price CT. Pediatric application of a dynamic axial external fixator. A Scientific Exhibit presented at the 55th Annual Meeting of the American Academy of Orthopaedic Surgeons; February 1988; Atlanta. Ga."},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Frykman G. Fractures of the distal end of the radius including sequelae - Shoulder hand finger syndrome disturbance in the distal radioulnar joint and impairment of nerve function. Acta Orthop Scand. 1967; I08(suppl):l-I55.","DOI":"10.3109\/ort.1967.38.suppl-108.01"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Cooney WP. External fixation of distal radius fractures. Clin Orthop. 1983; 180:44-49.","DOI":"10.1097\/00003086-198311000-00007"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Cooney WP. External pin fixation of unstable Colles' fractures. J Bone Joint Surg. 1 979; 6 1 A:840-845 .","DOI":"10.2106\/00004623-197961060-00006"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Weber SC Szabo RM. Severely comminuted distal radial fracture as an unsolved problem: Complications associated with external fixation and pins and plaster techniques. J Hand Surg. 1986; II A: 157-165.","DOI":"10.1016\/S0363-5023(86)80045-4"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Frykman GK Tooma GS. Boyle\u00a9 K Henderson R. Comparison of 1 1 external fixators for treatment of unstable wrist fractures. J Hand Surg. 1989; 14A:247-254.","DOI":"10.1016\/0363-5023(89)90015-4"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Chao EYS Hein TJ. Mechanical performance of the standard Orthofix external fixator. Orthopedics. 1988: 1 1:1057-1069.","DOI":"10.3928\/0147-7447-19880701-09"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T08:50:55Z","timestamp":1683103855000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-19900301-12"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1990,3]]},"references-count":10,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1990,3]]}},"alternative-id":["10.3928\/0147-7447-19900301-12"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-19900301-12","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[1990,3]]}}}