{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:44:16Z","timestamp":1760132656596},"reference-count":21,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[1991,5]]},"abstract":"<jats:p>Abstract<\/jats:p>\n          <jats:p>A prospective study of 119 consecutive primary ceramic total hip arthroplasties (Autophor, Smith &amp; Nephew) was performed. Follow up was 100% at a minimum of 3 years. Six hips were revised during the course of the study (5%). Harris hip scores were 29.0 preoperatively, 78.7 at 6 weeks, and 92.6 at 3.4 years (range: 62 to 100). Ninety-one percent of the 107 surviving hips at follow up had a good or excellent hip score. The clinical results matched those of Mittelmeier. Thigh pain was a frequent finding, but rarely presented a clinical problem. Our incidence of thigh pain may be higher than that of others because no patients were lost to follow up. The ceramic portion of the Autophor Ceramic Hip was well tolerated clinically and radiographically. The femoral component was responsible for 2% to 4% of the revisions, and we have now replaced it with a stem designed for bony stabilization.<\/jats:p>","DOI":"10.3928\/0147-7447-19910501-05","type":"journal-article","created":{"date-parts":[[2021,4,19]],"date-time":"2021-04-19T20:10:52Z","timestamp":1618863052000},"page":"523-531","source":"Crossref","is-referenced-by-count":18,"title":["PRIMARY CERAMIC HIP REPLACEMENT: A PROSPECTIVE STUDY OF 119 HIPS"],"prefix":"10.3928","volume":"14","author":[{"given":"Scott A","family":"Hoffinger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kristaps J","family":"Keggi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laurine E","family":"Zatorski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Harms J Mauste E. Tissue reaction to ceramic implant material. J Biomed Mater Res. 1979; 13:67.","DOI":"10.1002\/jbm.820130109"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Heimke G Griss P Jentschurg G Werner E. Direct anchorage of A 1203 ceramic hip components: Three years of clinical experience and results of further animal studies. J Biomed Mater Res. 1978; 12:57.","DOI":"10.1002\/jbm.820130108"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Rae T. The toxicity of metal used in orthopaedic prostheses. J Bone Joint Surg. 1981; 63B:435-440.","DOI":"10.1302\/0301-620X.63B3.7263760"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Rhinelander FW Rouweyha M Mimer JC Microvascular and histogenic responses to implantation of a porous ceramic into bone. J Biomed Mater Res. 1971;5:81.","DOI":"10.1002\/jbm.820050107"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Goldring SR Schiller AL Roelke M Rourke CM O'Neill DA Harris WH. The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg. 1983; 65A:575-584.","DOI":"10.2106\/00004623-198365050-00001"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Johanson NA Bullough PG Wilson PD Salvati EA. Ranawat CS. The microscopic anatomy of the bone-cement interface in failed total hip arthroplasties. Clin Orthop. 1987; 218:123-135.","DOI":"10.1097\/00003086-198705000-00018"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Light TR Keggi KJ. Anterior approach to hip arthroplasty. Clin Orthop. 152:255-260.","DOI":"10.1097\/00003086-198010000-00029"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. J Bone Joint Surg. 1969; 51 A:737-755.","DOI":"10.2106\/00004623-196951040-00012"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Brooker AF Bowerman JW Robinson RA Riley LH. Ectopic ossification following total hip replacement. J Bone Joint Surg. 1973; 55A: 1629-1632.","DOI":"10.2106\/00004623-197355080-00006"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Salvati EA Wilson PD Jolley MN Vakili F Aglietti P Brown GC. A ten year follow-up study of our first one hundred consecutive Charnley total hip replacements. J Bone Joint Surg. 1981; 63A:753-767.","DOI":"10.2106\/00004623-198163050-00010"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Engh CA Bobyn JD Glassman A. Porous coated hip replacement. J Bone Joint Surg. 1987; 69B:45-55.","DOI":"10.1302\/0301-620X.69B1.3818732"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Bisla RS Inglis AE Ranawat CS. Joint replacement surgery in patients under thirty. J Bone Joint Surg. 1976; 58A: 1098-1 104.","DOI":"10.2106\/00004623-197658080-00010"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Riegler HF Harris CM. Heterotopic bone formation after total hip arthroplasty. J Bone Joint Surg. 1976; 58A-.284.","DOI":"10.1097\/00003086-197606000-00027"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Charnley J. The long term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg. 1972; 54B:61-76.","DOI":"10.1302\/0301-620X.54B1.61"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Griss P Heimke G. Five years experience with ceramic metal composite hip endoprostheses. Arch Orthop Trauma Surg. 1981;98:157-171.","DOI":"10.1007\/BF00632972"},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Kozinn SC Johanson NA Bullough PG. The biologic interface between bone and cementiess femoral endoprostheses. J Arthroplasty. 1986; 1:249-259.","DOI":"10.1016\/S0883-5403(86)80015-8"},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Salvati EA Hughes P Lachiewicz P. Bilateral total hip replacement arthroplasty in one stage. J Bone Joint Surg. 1978; 60A:640-644.","DOI":"10.2106\/00004623-197860050-00008"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Ritter MA Stringer EA. Bilateral total hip arthroplasty: A single procedure. Clin Orthop. 1980; 149: 185-190.","DOI":"10.1097\/00003086-198006000-00025"},{"key":"e_1_3_1_20_1","doi-asserted-by":"crossref","unstructured":"19. Shih C-H Ho W-B. One-stage versus two-stage bilateral autophor ceramic total hip arthroplasty. Clin Orthop. 1985; 193:141-145.","DOI":"10.1097\/00003086-198503000-00018"},{"key":"e_1_3_1_21_1","doi-asserted-by":"crossref","unstructured":"20. Mittelmeier H. Total hip replacement with the Autophor cement-free ceramic prosthesis. In: Morscher E (ed). The Cementless Fixation of Hip Endoprostheses. Berlin: Springer-Verlag; 1984.","DOI":"10.1007\/978-3-642-69006-8_37"},{"key":"e_1_3_1_22_1","doi-asserted-by":"crossref","unstructured":"21. O'Leary JFM Mallory TH Kraus TJ Lombardi AV Lye CL. Mittelmeier ceramic total hip arthroplasty a retrospective study. J Arthroplasty. 1988; 3:87-96.","DOI":"10.1016\/S0883-5403(88)80057-3"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T13:54:39Z","timestamp":1683035679000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-19910501-05"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1991,5]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1991,5]]}},"alternative-id":["10.3928\/0147-7447-19910501-05"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-19910501-05","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[1991,5]]}}}