{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T16:39:00Z","timestamp":1773679140999,"version":"3.50.1"},"reference-count":42,"publisher":"SLACK, Inc.","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[1992,8]]},"abstract":"<jats:p>Abstract<\/jats:p>\n          <jats:p>From January 1982 through December 1988, 150 patients with 153 Winquist Class ITI and IY comminuted diaphyseal femur fractures due to high energy blunt trauma were treated with immediate plate fixation. A total of 260 major g\u00eanerai surgical systems were injured in 150 patients. Forty-nine patients did not have adequate preoperative spine radiographs due to positioning or time factors. Nineteen patient\u00ab had spine fractures; nine were diagnosed post-femoral fixation. The average injury severity score (ISS) was 22.7. Three patients died (2%). Our institution predicted mortality with this ISS for patients without pelvic or femur fractures at 15% (P= .0003).<\/jats:p>\n          <jats:p>Six patients moved to other states and three were lost to follow up due to noncompliance. One of us reviewed 141 fractures in 138 patients at a minimum of 12 months follow up and completion of treatment. Forty-nine fractures were open; 8 grade 1, 25 grade ?, 10 grade ???, 4 ???, 2 HIC. A total of 153 pelvic or ipsilateral major orthopedic injuries were present in 141 fractures. An additional 188 major associated orthopedic injuries were noted.<\/jats:p>\n          <jats:p>The average time to union was 17.2 weeks. One plate was applied in 11\u00b0 of varus. Five plates failed from fatigue and five from repeat traumas. Seven plate failures were rodded and healed within 8 weeks. There was one persistent nonunion. One fracture, open IIIC, became infected after uniting. One patient has 110\u00b0 of knee motion and 140 fractures have greater than 130\u00b0 of knee motion.<\/jats:p>\n          <jats:p>Plate fixation is a safe technique for immediate femoral stabilization in the face of high energy blunt trauma. Failures occur late and are easy to reconstruct Intramedullary nails are the preferred method of reconstruction. Ultimate knee function is excellent. Infection rates (1\/49) in open fractures are acceptably low.<\/jats:p>","DOI":"10.3928\/0147-7447-19920801-07","type":"journal-article","created":{"date-parts":[[2021,4,21]],"date-time":"2021-04-21T07:08:28Z","timestamp":1618988908000},"page":"907-916","source":"Crossref","is-referenced-by-count":37,"title":["IMMEDIATE PLATE FIXATION OF HIGHLY COMMINUTED FEMORAL DIAPHYSEAL FRACTURES IN BLUNT POLYTRAUMA PATIENTS"],"prefix":"10.3928","volume":"15","author":[{"given":"Barry L","family":"Riemer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Spencer L","family":"Butterfield","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles J","family":"Burke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Mathews","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Blumberg KD Foster WC. Blumberg JF et al. A comparison of the Brooker- Wills and Russell-Taylor naiLs for treatment of patients who have fractures of the femoral shaft. J Bone Joint Surg. 1 990; 72?: 1019-1 024.","DOI":"10.2106\/00004623-199072070-00010"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Bone LB. Johnson KD. Weigelt J. Scheinberg R. Early vs delayed stabilization of femoral fractures. A prospective randomized study. J Bone Joint Surg. 1989; 71A:336-340.","DOI":"10.2106\/00004623-198971030-00004"},{"key":"e_1_3_1_4_1","unstructured":"3. Brumback RJ Ellison PS. Poka A et al. Intramedullary nailing of open fractures of the femoral shaft. J Bone Joint Surg 1989; 7 1 A: 1 324- 1 331."},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Dabezies EJ D'Ambrosia R Shoji H Norris R Murphy G. Fractures of me femoral shaft treated by external Fixation with the Wagner device. \/ Bone Joint Surg. 1984; 66A:360-364.","DOI":"10.2106\/00004623-198466030-00007"},{"key":"e_1_3_1_6_1","unstructured":"5. Dencker H. Shaft fractures of the femur. A comparative study of the results of various methods of treatment in 1003 cases. Acta Chir Stand. 1965; 1 30: 174-184."},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Johnson KD Cadambi A Seibert GB. Incidence of adult respiratory distress syndrome in patients with multiple musculoskeletal injuries: effect of early operative stabilization of fractures. J Trauma. 1985; 25:375-384.","DOI":"10.1097\/00005373-198505000-00001"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Lhowe DW Hansen ST. Immediate nailing of open fractures of the femoral shaft. J Bone Joint Surg. 1988; 70A:8 12-820.","DOI":"10.2106\/00004623-198870060-00003"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Meek RN. Vivoda EE Pirani S. Comparison of mortality of patients with multiple injuries according io type of fracture treatment - a retrospective age- and injurymatched series. Injury. 1986; 17:2-4.","DOI":"10.1016\/0020-1383(86)90003-3"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Seidel R LaDuca J Hassett JM et al. Blunt multiple trauma (ISS 36) femur traction and the pulmonary failureseptic state. Ann Surg. 1985; 202:283-295.","DOI":"10.1097\/00000658-198509000-00003"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Pahud B. Vasey H. Delayed internal fixation of femoral shaft fractures - is there an advantage? J Bone Joint Surg. l987;69B:39l-394.","DOI":"10.1302\/0301-620X.69B3.3584191"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Webb LX Gristina AG Fowler HL. Unstable femoral shaft fractures: a comparison of interlocking nailing vs traction and casting methods. J Orthop Trauma. 1988; 2:10-12.","DOI":"10.1097\/00005131-198802000-00003"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Brumback RJ Reilly JP. Poka A et al. Intramedullary nailing of femoral shaft fractures. Part 1: Decisionmaking errors with interlocking fixation. J Bone Joint Surg. 1988; 70A: 1441 -1452.","DOI":"10.2106\/00004623-198870100-00002"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Johnson KD. Greenberg M. Comminuted femoral shaft fractures. Orthop Clin North Am. 1987; 18:133-147.","DOI":"10.1016\/S0030-5898(20)32287-2"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Murphy CP D'Ambrosia RD Dabezies EJ et al. Complex femur fractures: treatment with the Wagner external fixation device or the Gross-Kempf interlocking nail. J Trauma. 1988;28:1553-1561.","DOI":"10.1097\/00005373-198811000-00006"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Winquist RA Hansen ST Clawson DK. Closed intramedullary nailing of femoral fractures. A report of 520 cases. J Bone Joint Surg. 1984; 66A.529-539.","DOI":"10.2106\/00004623-198466040-00006"},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Wiss DA. Brien WW Stetson WB. Interlocked nailing for treatment of segmental fractures of the femur. J Bone Joint Surg. 1990; 72A:724-728.","DOI":"10.2106\/00004623-199072050-00012"},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Wiss DA Fleming CH Matta JM Clark D. Comminuted and rotational Iy unstable fractures of the femur treated with an interlocking nail. Clin Orthop 1986; 212:35-47.","DOI":"10.1097\/00003086-198611000-00006"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Zuckerman JD Veith RG Johnson KD et al. Treatment of unstable femoral shaft fractures with closed interlocking intramedullary nailing. J Orthop Trauma. 1987; 1:209-218.","DOI":"10.1097\/00005131-198701030-00003"},{"key":"e_1_3_1_20_1","doi-asserted-by":"crossref","unstructured":"19. O'Beirne J O'Connell RJ White JM Flynn M. Fractures of the femur treated by femoral plating using the anterolateral approach. Injury. 1986; 17:387-390.","DOI":"10.1016\/0020-1383(86)90077-X"},{"key":"e_1_3_1_21_1","doi-asserted-by":"crossref","unstructured":"20. Cheng JCY Tse PYT. Chow YYN. The place of the dynamic compression plate in femoral shaft fractures. Injury. 1985: 16:529-534.","DOI":"10.1016\/0020-1383(85)90078-6"},{"key":"e_1_3_1_22_1","unstructured":"21. Magerl F Wyss A Brunner CH Binder W. Plate osteosynthesis of femoral shaft fractures in adults. A followup study. Clin Orthop. 1979; 138:62-73."},{"key":"e_1_3_1_23_1","unstructured":"22. Ruedi TP. Luscher JN. Results after internal fixation of comminuted fractures of the femoral shaft with DC plates. Clin Orthop 1979; 138:74-76."},{"key":"e_1_3_1_24_1","doi-asserted-by":"crossref","unstructured":"23. Gustilo RB. Mendoza RM Williams DN. Problems in the management of Type 111 tsevere) open fractures: a new classification of Type III open fractures. J Trauma. 1984; 24:742-746.","DOI":"10.1097\/00005373-198408000-00009"},{"key":"e_1_3_1_25_1","unstructured":"24. Coenen L Broos P Stappaerts K Willokx T Gruwez JA. A plate osteosynmesis for femoral shaft fractures in adults. Acta Chir BeIg. 1985; 85:260-267."},{"key":"e_1_3_1_26_1","doi-asserted-by":"crossref","unstructured":"25. Paul RG. Sawka MW Whitelaw GP. Fractures of the ipsilateral femur and tibia: emphasis on tntra-articular and soft tissue injury. J Orthop Trauma. 1990; 4:309-314.","DOI":"10.1097\/00005131-199004030-00013"},{"key":"e_1_3_1_27_1","unstructured":"26. Veith RG. Winquist RA Hansen ST. Ipsilateral fractures of the femur and tibia. A report of 57 consecutive cases. J Bone Joint Surg. 1 984; 66A:99 1 - 1 002."},{"key":"e_1_3_1_28_1","doi-asserted-by":"crossref","unstructured":"27. Baker SP O'Neill B. Haddon W Jr Long WB. The injury severity score: a memod of describing patients with multiple injuries and evaluating emergency care. J Trauma. 1974; 14:187-1%.","DOI":"10.1097\/00005373-197403000-00001"},{"key":"e_1_3_1_29_1","doi-asserted-by":"crossref","unstructured":"28. Ward WG Nunley JA. Occult orthopaedic trauma in the multiply injured patient. J Orthop Trauma. 1991; 5:308-312.","DOI":"10.1097\/00005131-199109000-00009"},{"key":"e_1_3_1_30_1","unstructured":"29. Gamier E. Rahn BA. Perren SM. Effect of steel vs composite plastic plates on internal and external remodeling of intact long bones. Orthopaedic Transactions. 1986; 10:391."},{"key":"e_1_3_1_31_1","unstructured":"30. Rhineiander FW. The vascular response of bone to internal fixation. In: Browner BD Edwards CC. eds. The Science and Practice of Intramedullary Nailing. Philadelphia Pa: Lea & Febiger; 1987; 3:25-59!"},{"key":"e_1_3_1_32_1","doi-asserted-by":"crossref","unstructured":"31. Woo SL-Y Akeson WH Coutts RD et al. A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffness. J Bone Joint Surg. 1976: 58 A: 190-195.","DOI":"10.2106\/00004623-197658020-00005"},{"key":"e_1_3_1_33_1","doi-asserted-by":"crossref","unstructured":"32. M\u00fcller ME AUgower M Schneider R Willenegger H. Manual of Internal Fixation. New York. NY: SpringerVerlag; 1991:12-95.","DOI":"10.1007\/978-3-662-02695-3"},{"key":"e_1_3_1_34_1","unstructured":"33. Claudi B. Schlapfer F Cordey J Perren SM Ailgower M. Die schr\u00e4ge plattenzugschraube - in vitro - messungen der Stabilit\u00e4t an queren Osteotomien des tibiachschaftes. HeIv Olir Acta. 1 979; 46; 177- 182."},{"key":"e_1_3_1_35_1","unstructured":"34. Regazzoni P. Osteosynthesen An Roerenknochen: Techische Und Biologische Untersuchungen Zur Stabilitasi Und Heilunng. Habilitationsschrift zur Erlangung der venia docendi fur Chirurgie an der Universita! Basel. Doctoral Thesis 1982."},{"key":"e_1_3_1_36_1","doi-asserted-by":"crossref","unstructured":"35. Hollmann MW Horowitz M Femoral fractures secondary to low velocity missiles: treatment with delayed intramedullary fixation. J Orthap Trauma. 1990; 4:64-69.","DOI":"10.1097\/00005131-199003000-00011"},{"key":"e_1_3_1_37_1","doi-asserted-by":"crossref","unstructured":"36. Chapman MW. The role of intramedullary fixation in open fractures. Clin Orthop. 1986; 212:26-33.","DOI":"10.1097\/00003086-198611000-00005"},{"key":"e_1_3_1_38_1","doi-asserted-by":"crossref","unstructured":"37. Green A Traflon PG. Early complication in the management of open femur fractures: a retrospective study. J Orthap Trauma. 1991; 5:56-61.","DOI":"10.1097\/00005131-199103000-00009"},{"key":"e_1_3_1_39_1","doi-asserted-by":"crossref","unstructured":"38. O'Keete R Riemer BL Butterfield S. Harvesting of autogenous cancellous bone graft from the proximal tibia metaphysis: a review of 230 cases. J Orthap Trauma. 1991; 5:469-474.","DOI":"10.1097\/00005131-199112000-00014"},{"key":"e_1_3_1_40_1","doi-asserted-by":"crossref","unstructured":"39. Sprenger TR. Fractures of the shaft of the femur treated with a single AO piale. South Med J. 1983; 76:471-474.","DOI":"10.1097\/00007611-198304000-00014"},{"key":"e_1_3_1_41_1","doi-asserted-by":"crossref","unstructured":"40. Thompson F O' Bei me J Gallagher J Sheehan J Quinlan W. Fractures of the femoral shaft treated by plating. Injun: 1985; 16:535-538.","DOI":"10.1016\/0020-1383(85)90079-8"},{"key":"e_1_3_1_42_1","doi-asserted-by":"crossref","unstructured":"41. Kempf I Gross A Beck G. Closed locked intramedullary nailing. Its application io comminuted fractures of the femur. J Bone Joint. Surg. 1985; 67A:709-720.","DOI":"10.2106\/00004623-198567050-00005"},{"key":"e_1_3_1_43_1","doi-asserted-by":"crossref","unstructured":"42. Webb LX. Winquist RA. Hansen ST. Intramedullary nailing and reaming for delayed union or nonunion of the femoral shaft. A report of 105 consecutive cases. Clin Orrhop. 1986;212:133-141.","DOI":"10.1097\/00003086-198611000-00015"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T02:15:04Z","timestamp":1683080104000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-19920801-07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1992,8]]},"references-count":42,"journal-issue":{"issue":"8","published-print":{"date-parts":[[1992,8]]}},"alternative-id":["10.3928\/0147-7447-19920801-07"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-19920801-07","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[1992,8]]}}}