{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T04:16:04Z","timestamp":1683087364243},"reference-count":16,"publisher":"SLACK, Inc.","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2000,7]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>This study investigated the effect of intramedullary corticocancellous bone plug on the fixation and stability of hydroxyapatite-coated femoral stems in total hip arthroplasty (THA). Intramedullary corticocancellous bone plug was used in 30 patients with hydroxyapatite-coated femoral stems (group A) and a consecutive series of 30 patients with hypdroxyapatite-coated stems without bone plug served as the control group (group B). Patients underwent clinical and radiographic follow-up for at least 2 years.<\/jats:p>\n          <jats:p>The addition of corticocancellous bone plug to the hydroxyapatite-coated stem significantly improved clinical and radiographic results. The mean Harris Hip Score at 3 and 6 months postoperatively was 92 and 94 in group A, and 84 and 87 points in group B (P&lt;.004 and P&lt;.001, respectively). There was no significant difference between groups at 1 year postoperatively and thereafter. The predominant cause for the difference was the thigh pain score, which was reduced at both 3 and 6 months in group A compared to group B (P&lt;.01 and P&lt;.05, respectively). There also were statistical differences between the two groups regarding radiographic signs. The evidence of endosteal bone formation in group A patients was superior at 3 and 6 months (P&lt;.001 and P&lt;.01, respectively). The appearance of a radiolucent line was significant in group B patients at 3 and 6 months (P&lt;.001). Femoral stem migration of 3 mm was noted in three group B patients versus no group A patients (P&lt;.05). These shortterm clinical and radiographic results suggest corticocancellous bone plug can provide early pain relief and durable implant fixation, but long-term follow-up should be considered.<\/jats:p>","DOI":"10.3928\/0147-7447-20000701-14","type":"journal-article","created":{"date-parts":[[2021,4,21]],"date-time":"2021-04-21T07:42:59Z","timestamp":1618990979000},"page":"681-685","source":"Crossref","is-referenced-by-count":2,"title":["The Effect of Intramedullary Bone Plug on Femoral Stem Migration of Hydroxyapatite-Coated Hip Arthroplasty"],"prefix":"10.3928","volume":"23","author":[{"given":"M","family":"Kligman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"Roffman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Wixson RL Stulberg SD Mehlhoff M. Total hip replacement with cemented uncemented and hybrid prostheses. A comparison of clinical and radiographic results at 2 to 4 years. J Bone Joint Surg Am. 1991; 73:257-270.","DOI":"10.2106\/00004623-199173020-00014"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Collier JP Mayor MB. Chae JC Suprenant VA Suprenant HP Dauphinais LA. Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. Clin Orthop. 1988;235:173-180.","DOI":"10.1097\/00003086-198810000-00017"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Engh CA Massin P Suthers KE. Roentgenographs assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop. 1990; 257:107-128.","DOI":"10.1097\/00003086-199008000-00022"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Geesink RGT de Groot K Klein CPAT. Chemical implant fixation using hydroxyl-apatite coatings: the development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop. 1987; 225:147-170.","DOI":"10.1097\/00003086-198712000-00014"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Geesink RGT de Grot K Klein CPAT. Bonding of bone to apatite-coated implants. J Bone Joint Surg Br. 1988; 70:17-22.","DOI":"10.1302\/0301-620X.70B1.2828374"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Soballe K Hansen ES BrockstedtRasmussen H Pedersen CM Bunger C. Hydroxyapatite coating enhances fixation of porous coated implants: a comparison in dogs between press fit and noninterference fit. Acta Orthop Scand. 1990; 61:299-306.","DOI":"10.3109\/17453679008993521"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Soballe K Hansen ES Brockstedt-Rasmussen HB Bunger C. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. J Bone Joint Surg Br. 1993; 75:270-278.","DOI":"10.1302\/0301-620X.75B2.8444949"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Pilliar RM Cameron HV Welsh RP Binnington AG. Radiographic and morphologic studies of load-bearing porous-surfaced structured implants. Clin Orthop. 1981; 156:249-257.","DOI":"10.1097\/00003086-198105000-00037"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Campbell ACL Rorabeck CH Bourne RB Chess D Nott L. Thigh pain after cementless hip arthroplasty; annoyance or ill omen. J Bone Joint Surg Br. 1992; 74:63-66.","DOI":"10.1302\/0301-620X.74B1.1732268"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Burkart BC1 Bourne RB. Rorabeck CH Kirk PG. Thigh pain in cementless total hip arthroplasty: a comparison of two systems at 2 years' follow-up. Orthop Clin North Am. 1993; 24:645-653.","DOI":"10.1016\/S0030-5898(20)31844-7"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. D'Antonio JA Capello WN Jaffe WL. Hydroxylapatite-coated hip implants. Multicenter 3-year clinical and roentgenographic results. Clin Orthop. 1992;285:102-115.","DOI":"10.1097\/00003086-199212000-00015"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Geesink RGT. Hydroxyapatite-coated total hip prostheses: 2 year clinical and roentgenographs results of 100 cases. Clin Onhop. 1990; 261:39-58","DOI":"10.1097\/00003086-199012000-00007"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Callaghan JJ Dysart SH Savory CG. The uncemented porous-coated anatomic total hip prosthesis: 2-year result of a prospective consecutive series. J Bone Joint Surg Am. 1988;70:337-46.","DOI":"10.2106\/00004623-198870030-00004"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Capello WN. D'Antonio JA Feinberg JR. Manley MT. Hydroxyapatite-coated total hip femoral components in patients less than 50 years old. Clinical and radiographic results after 5 to 8 years of follow-up. J Bone Joint Surg Am. 1997; 79:1023-1029.","DOI":"10.2106\/00004623-199707000-00008"},{"key":"e_1_3_1_16_1","unstructured":"15. Hedley AK Oruen TA Borden LS Hungerford DS. Haberman E Kenna 1W. Noyear follow-up of the PCA noncemented total hip replacement. Hip. 1987; 225-250."},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Havelin LI Espehaug B Vollset SE Engesaeter LB. Early aseptic loosening of uncemented femoral components in primary total hip replacement: a review based on the Norwegian arthroplasty register. J Bone Joint Surg Br 1995; 77:11-17.","DOI":"10.1302\/0301-620X.77B1.7822364"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T02:22:48Z","timestamp":1683080568000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-20000701-14"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,7]]},"references-count":16,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2000,7]]}},"alternative-id":["10.3928\/0147-7447-20000701-14"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-20000701-14","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,7]]}}}