{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T10:05:02Z","timestamp":1769162702524,"version":"3.49.0"},"reference-count":19,"publisher":"SLACK, Inc.","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2001,8]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>Outcome of the acetabular component in 90 consecutive primary noncemented total hip arthroplasties (THAs) was prospectively studied. The acetabular cup consisted of a hemispherical titanium alloy shell with a titanium fiber-mesh porous coating and a modular polyethylene liner (Harris-Galante Porous-1, Zimmer, Warsaw, Ind). The cup was implanted using line-to-line reaming with adjunctive dome screw fixation. The femoral component consisted of a titanium alloy stem with titanium fibermesh porous coating and a 28-mm cobalt-chrome modular head. Mean patient age was 53 years (range: 27-75 years); male:female ratio was 48:42; and mean follow-up was 6 years (range: 4.5-8 years).<\/jats:p>\n          <jats:p>One acetabular component was revised for aseptic loosening. Of 81 unrevised hips available for follow-up, mean Harris hip score was 57 preoperatively and 96 at final follow-up (72% excellent, 15% good, 13% fair, and none poor). Of 61 unrevised hips with adequate radiographic follow-up, radiographic failure (complete periprosthetic radiolucency) was evident in 3 (4.9%) and periacetabular osteolysis in none. Radiographic failure did not correlate with poor clinical outcome. Linear polyethylene wear rate (mean: 0.13 mm\/year) did not correlate with age, gender, weight, outcome, or cup abduction angle, but did correlate with the presence of femoral periprosthetic osteolysis (0.18 mm\/year with femoral osteolysis versus 0.11 mm\/year without; P=.01).<\/jats:p>\n          <jats:p>This series of porous-coated hemispherical cups demonstrated excellent intermediate-term clinical and radiographic outcome, comparable with similarly favorable results reported by the prosthesis designers. A potentially adverse effect of polyethylene wear on the longevity of a THA was supported by a positive correlation between polyethylene wear rate and femoral osteolysis.<\/jats:p>","DOI":"10.3928\/0147-7447-20010801-16","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T08:01:36Z","timestamp":1619078496000},"page":"747-751","source":"Crossref","is-referenced-by-count":6,"title":["The Harris-Galante Porous Acetabular Component at Intermediate Follow-Up"],"prefix":"10.3928","volume":"24","author":[{"given":"Darryl D","family":"D'Lima","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arnold A","family":"Yashar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric J","family":"Venn-Watson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clifford W","family":"Colwell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard H","family":"Walker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Owen TD. Moran CG. Smith SR. Pinder IM. Results of uncemented porous-coated anatomic total hip replacement. J Bone Joint Surg Br. 1994; 76:258-262.","DOI":"10.1302\/0301-620X.76B2.8113287"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Kim YH Kim VE. Uncemented porouscoated anatomic total hip replacement. Results at 6 years in a consecutive series. J Bone Joint Surg Br. 1993:75:6-13.","DOI":"10.1302\/0301-620X.75B1.8421036"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Kim YH Kim VE. Cementless porouscoated anatomic medullary locking total hip prostheses. J Arthroplasty. 1994; 9:243-252.","DOI":"10.1016\/0883-5403(94)90078-7"},{"key":"e_1_3_1_5_1","unstructured":"4. Pellicci PM. Pelvis hip and femur: reconstruction. In: Poss R. Bucholz RW. Frymoyer JW. Gelberman RH. Hensinger RN Morrey BF eds. Orthopaedic Knowledge Update 3. Rosemont III: American Academy of Orthopaedic Surgeons; 1990:529-543."},{"key":"e_1_3_1_6_1","unstructured":"5. Glassman AH. Cementless primary total hip replacement. In: Callaghan JJ Dennis DA Paprosky WG Rosenberg AG eds. Orthopaedic Knowledge Update: Hip and Knee Reconstruction. Rosemont Dl: American Academy of Orthopaedic Surgeons; 1995:191."},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969; 51:737-755.","DOI":"10.2106\/00004623-196951040-00012"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Massin P Schmidt L. Engh CA. Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty. 1989;4:245-251.","DOI":"10.1016\/S0883-5403(89)80020-8"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Delee JG. Charnley J. Radiological demarcation of cemented sockets in total hip replacement Clin Orthop. 1976; 121:20-32.","DOI":"10.1097\/00003086-197611000-00003"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Engh CA Massin P Suthers KE. Roentgen ographic assessment of the biological fixation of porous-surfaced femoral components. Clin Orthop. 1990;257:107-128.","DOI":"10.1097\/00003086-199008000-00022"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Livermore J Ilstrup D Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518-528.","DOI":"10.2106\/00004623-199072040-00008"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Gruen TA. McNiece GM. Amstutz HC. \"Modes of failure\" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop. 1979; 141:17-27.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Brooker AF Bowerman JW Robinson RA Riley LH Jr. Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am. 1973; 55:1629-1632.","DOI":"10.2106\/00004623-197355080-00006"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Woolson ST Maloney WJ. Cementless total hip arthroplasty using a porous-coated prosthesis for bone ingrowth fixation. 3 Vi-year follow-up. J Arthroplasty. 1992; 7(Suppl):381-388.","DOI":"10.1016\/S0883-5403(07)80028-3"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Schmalzried TP Harris WH. The HarrisGalante porous-coated acetabular component with screw fixation. Radiographic analysis of 83 primary hip replacements at a minimum of 5 years. J Bone Joint Surg Am. 1992; 74:11301139.","DOI":"10.2106\/00004623-199274080-00002"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Tompkins GS Jacobs JJ Kull LR Rosenberg AG Galante JO. Primary total hip arthroplasty with a porous-coated acetabular component. Seven-to-10 year results. J Bone Joint Surg Am. 1997;79:169-176.","DOI":"10.2106\/00004623-199702000-00002"},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Onsten L Carlsson AS Ohlin A Nilsson JA. Migration of acetabular components inserted with and without cement in one-stage biiaterai hip arthroplasty. A controlled randomized study using roentgenstereophotogrammetric analysis. J Bone Joint Surg Am. 1994; 76:185-194.","DOI":"10.2106\/00004623-199402000-00004"},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Karrholm J Snorrason F. Migration of porous-coated acetabular prostheses fixed with screws: roentgen stereophotogrammetric analysis. J Orthop Res. 1992; 10:826-835.","DOI":"10.1002\/jor.1100100612"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Schmalzried TP Wessinger SJ Hill GE. Harris WH. The Harris-Galante porous acetabular component press-fit without screw fixation. Five-year radiographic analysis of primary cases. J Arthroplasty. 1994;9:235-242.","DOI":"10.1016\/0883-5403(94)90077-9"},{"key":"e_1_3_1_20_1","doi-asserted-by":"crossref","unstructured":"19. Incavo SJ Ames SE DeFazio FA Howe JG. Cementless hemisphere acetabular components. A 4- to 8-year follow-up report. J Arthroplasty. 1996; 11:298-303.","DOI":"10.1016\/S0883-5403(96)80082-9"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T10:28:56Z","timestamp":1683109736000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-20010801-16"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,8]]},"references-count":19,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2001,8]]}},"alternative-id":["10.3928\/0147-7447-20010801-16"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-20010801-16","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,8]]}}}