{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T15:38:50Z","timestamp":1773157130572,"version":"3.50.1"},"reference-count":38,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2004,1]]},"abstract":"<jats:p>External fixation is the treatment of choice for various perl\u00b7 articular, supracondylar, and pilon fractures. The hybrid thin wire external fixator is a modular, minimally invasive device that provides stabilization, reduces the risk of infection, and allows early loading and mobilization, which are crucial for bone healing.<\/jats:p>","DOI":"10.3928\/0147-7447-20040101-20","type":"journal-article","created":{"date-parts":[[2019,12,17]],"date-time":"2019-12-17T16:30:40Z","timestamp":1576600240000},"page":"59-62","source":"Crossref","is-referenced-by-count":17,"title":["Hybrid Thin Wire External Fixation: An Effective, Minimally Invasive, Modular Surgical Tool for the Stabilization of Periarticular Fractures"],"prefix":"10.3928","volume":"27","author":[{"given":"Alexander","family":"Lerner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haim","family":"Stein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Buckwalter JA Grodzinsky AJ. Loading of healing bone fibrous tissue and muscle: implications for orthopaedic practice. JAm Acad Orthop Surg. 1999:7:291-299.","DOI":"10.5435\/00124635-199909000-00002"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Stein H Perren SM Cordey J Kenwright J. Mosheiff R. Francis MJO The muscle bed - a crucial factor for fracture healing: a physiological concept. Orthopedics. 2002; 25:1379-1383.","DOI":"10.3928\/0147-7447-20021201-16"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Delprete C Gola MM. Mechanical performance of external fixators with wires for the treatment of bone fractures I: load-displacement behavior. Biomech Eng. 1993: 115:29-36.","DOI":"10.1115\/1.2895467"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Delprete C Gola MM. Mechanical performance of external fixators with wires for the treatment of bone fractures II: wire tension and slippage. Biomech Eng. 1993; 115:37-42.","DOI":"10.1115\/1.2895468"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Stein H Perren SM Mosheiff R Baumgart F Cordey J. Decline in transfixing K-wire tension of the circular external fixator: experimental continuous in vivo measurements. Orthopedics. 2001; 24:985-989.","DOI":"10.3928\/0147-7447-20011001-20"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Stein H Weize I Hoerer D. Lemer A Rozen N Nierenberg G. Musculoskeletal trauma: high- and low-energy injuries. Orthopedics. 1999: 22:965-967.","DOI":"10.3928\/0147-7447-19991001-14"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Lerner A Stahl S Stein H. Hybrid external fixation in high-energy elbow fractures: a modular system with a promising future. J Trauma. 2000;49:1017-1022.","DOI":"10.1097\/00005373-200012000-00007"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Stein H Mosheiff R Baumgart F Frigg R Perren SM Cordey J. The hybrid ring tubular external fixator: a biomechanical study. Clin Biomech (Bristol Avon). 1997: 12:259-266.","DOI":"10.1016\/S0268-0033(97)00006-5"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Lerner A Horer D Merom L Stein H. Modular use of external fixation configurations for treatment of complex and severely injured limbs. Eur J Trauma. 2003; 29:108-111.","DOI":"10.1007\/s00068-003-1184-9"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Zarzhevsky N. Coleman R Volpin G Fuchs D Stein H Reznick AZ. Muscle recovery after immobilisation by external fixation. J Bone Joint Surg Br. 1999;81:896-901.","DOI":"10.1302\/0301-620X.81B5.0810896"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Swiontkowski MF Sands AK Agel J Diab M Schwappach JR Kreder HJ Interobserver variation in the AO\/OTA fracture classification system for pilon fractures: is there a problem? J Orthop Trauma. 1997; 1 1:462-470.","DOI":"10.1097\/00005131-199710000-00002"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Koval KJ Hoehl JJ Kummer FJ Simon JA. Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate a locked buttress plate and the 95-degree blade plate. J Orthop Trauma. 1997; 11:521-524.","DOI":"10.1097\/00005131-199710000-00010"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Sanders R Regazzom P. Ruedi T. Treatment of supracondylar-intracondylar fractures of the femur using the dynamic condylar screw. J Orthop Trauma. 1989;3:214-222.","DOI":"10.1097\/00005131-198909000-00006"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Bankston AB Keating EM Saha S. The biomechanical evaluation of intramedullary nails in distal femoral shaft fractures. Clin Orthop. 1992: 276:277-282.","DOI":"10.1097\/00003086-199203000-00039"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Sanders R Swiontkowski M. Rosen H et al. Double-plating of comminuted unstable fractures of the distal part of the femur. J Bone Joint Surg Am. 1991;73:341-346.","DOI":"10.2106\/00004623-199173030-00004"},{"key":"e_1_3_1_17_1","unstructured":"16. Chevally F. Amsutz CH Bally A. Experimental analysis of external fixation of comminuted fractures of the femur. J Orthop Surg. 1993: 7:1-7."},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Fleming B Paley D Kristiansen T Pope M. A biomechanical analysis of the Ilizarov external fixator. Clin Orthop. 1989; 241:90-105.","DOI":"10.1097\/00003086-198904000-00012"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Goodship A Kenwright I. The influence of induced micromovemem upon the healing of experimental tibial fractures. J Bone Joint Surg Br 1985;67:650-655.","DOI":"10.1302\/0301-620X.67B4.4030869"},{"key":"e_1_3_1_20_1","doi-asserted-by":"crossref","unstructured":"19. Kenwright J. The principles of use of external fixation. Curr Orthop. 1992; 6:214-219.","DOI":"10.1016\/0268-0890(92)90018-9"},{"key":"e_1_3_1_21_1","doi-asserted-by":"crossref","unstructured":"20. Neer CS II Grantham SA Shelton ML. Supracondylar fracture of the adult femur: a study of one hundred and ten cases. J Bone Joint Surg Am. 1967;49:591-613.","DOI":"10.2106\/00004623-196749040-00001"},{"key":"e_1_3_1_22_1","unstructured":"21. Rockwood C A ed. Rockwood and Green 's Fractures in Adults. 4th ed. Philadelphia. Pa: Lippincott Williams & Wilkins; 1996."},{"key":"e_1_3_1_23_1","doi-asserted-by":"crossref","unstructured":"22. Arazi M Memik R Ogun TC Yel M. Ilizarov external fixation for severely comminuted supracondylar and intercondylar fractures of the distal femur J Bone Joint Surg Br. 2001; 83:663-667.","DOI":"10.1302\/0301-620X.83B5.0830663"},{"key":"e_1_3_1_24_1","doi-asserted-by":"crossref","unstructured":"23. Marsh JL Jansen H Yoong HK Found EM Jr Supracondylar fractures of the femur treated by external fixation. J Orthop Trauma. 1997; 11:405-411.","DOI":"10.1097\/00005131-199708000-00004"},{"key":"e_1_3_1_25_1","doi-asserted-by":"crossref","unstructured":"24. Thordarson DB. Complications after treatment of tibial pilon fractures: prevention and management strategies J Am Acad Orthop Surg. 2000; 8:253-265.","DOI":"10.5435\/00124635-200007000-00006"},{"key":"e_1_3_1_26_1","doi-asserted-by":"crossref","unstructured":"25. McFerran MA. Smith SW. Boulas HJ Schwartz HS. Complications encountered in the treatment of pilon fractures. J Orthop Trauma. 1992; 6:195-200.","DOI":"10.1097\/00005131-199206000-00011"},{"key":"e_1_3_1_27_1","doi-asserted-by":"crossref","unstructured":"26. Teeny SM Wiss DA. Open reduction and internal fixation of tibial plafond fractures. Variables contributing to poor results and complications. Clin Ortlwp. 1993; 292:108-117.","DOI":"10.1097\/00003086-199307000-00013"},{"key":"e_1_3_1_28_1","doi-asserted-by":"crossref","unstructured":"27. Dirschl DR Adams GL. A critical assessment of factors influencing reliability in the classification of fractures using fractures of the tibial plafond as a model. J Orthop Trauma. 1997; 11:471-476.","DOI":"10.1097\/00005131-199710000-00003"},{"key":"e_1_3_1_29_1","doi-asserted-by":"crossref","unstructured":"28. Kellam JF Waddell JP. Fractures of the distal tibial metaphysis with intraarticular extension - the distal tibial explosion fracture. J Trauma. 1979; 19:593-601.","DOI":"10.1097\/00005373-197908000-00007"},{"key":"e_1_3_1_30_1","doi-asserted-by":"crossref","unstructured":"29. Wyrsch B McFerran MA. McAndrew M. et al. Operative treatment of fractures of the tibial plafond. A randomized prospective study. J Bone Joint Surg Am. 1 996; 78: 1646-195?.","DOI":"10.2106\/00004623-199611000-00003"},{"key":"e_1_3_1_31_1","doi-asserted-by":"crossref","unstructured":"30. Bone L Stegemann P McNamara K Seibel R. External fixation of severely comminuted and open tibial pilon fractures. Clin Orthop. 1993;292:101-107.","DOI":"10.1097\/00003086-199307000-00012"},{"key":"e_1_3_1_32_1","unstructured":"31. Mehne DK. Trauma to the adult elbow and fractures of the distal humerus. In: Browne BD Jupiter JB Levine AM Trafton PG eds Skeletal Trauma. Philadelphia. Pa: WB Saunders Co; 1992:1125-1176."},{"key":"e_1_3_1_33_1","unstructured":"32. Asprinio D Helfet DL. Fractures of the distal humerus. In: Levine AM ed. Orthopaedic Knowledge Update; Trauma. Chicago. IU: American Academy of Orthopaedic Surgeons; 1996:35-45."},{"key":"e_1_3_1_34_1","doi-asserted-by":"crossref","unstructured":"33. Skaggs DL Hale JM. Buggay S Kay RM. Use of hybrid external fixator for a severely comminuted juxta-articular fracture of the distal humerus. J Orthop Trauma. 1998; 6:439-442.","DOI":"10.1097\/00005131-199808000-00015"},{"key":"e_1_3_1_35_1","doi-asserted-by":"crossref","unstructured":"34. Ring D. Jupiter JB Toh S. Salvage of contaminated fractures of the distal humerus with thin wire external fixation. Clin Orthop. 1999: 359:203-208.","DOI":"10.1097\/00003086-199902000-00022"},{"key":"e_1_3_1_36_1","unstructured":"35. Raschke MJ Hoffmann R Kbodadadyan C von Foumier C Sudkamp NP Haas NP. Combination of the Ilizarov ring fixator with the unilateral AO tube fixator. Initial clinical experiences with the hybrid system [German]. Unfallvhirurg. i995; 98:627-632."},{"key":"e_1_3_1_37_1","doi-asserted-by":"crossref","unstructured":"36. Ilizarov GA. Transosseous osteosynthesis. In: Theoretical and Clinical Aspects of the Regeneration and Growth of Tissue. Berlin Gerronay: Springer-Verlag; 1992:369-452.","DOI":"10.1007\/978-3-642-84388-4_8"},{"key":"e_1_3_1_38_1","doi-asserted-by":"crossref","unstructured":"37. Stein H Cordey J Mosheiff R Perren SM. Observations on the stiffness of neogenetic bone produced by distraction or segment transport and its relationship to bone density. In: Wolter D. Hansis M. Havemann D eds. Externe und Interne Fixateur Systeme. Berlin Germany: Springer- Verlag; 1995:4749.","DOI":"10.1007\/978-3-642-79598-5_10"},{"key":"e_1_3_1_39_1","unstructured":"Section Editor: Alan E. Freeland MD"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T07:25:14Z","timestamp":1683098714000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-20040101-20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,1]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2004,1]]}},"alternative-id":["10.3928\/0147-7447-20040101-20"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-20040101-20","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,1]]}}}