{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T20:12:40Z","timestamp":1762459960482},"reference-count":13,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2005,9,2]]},"abstract":"<jats:p>abstract<\/jats:p>\n          <jats:p>Femoral deformity in primary total hip arthroplasty can make restoration of joint biomechanics difficult. The S-ROM (DePuy Orthopaedics Inc., Warsaw, lnd) prosthesis' modular design allows for independent matching of diaphyseal and metaphyseal anatomy. Corrective osteotomy may also be performed because the stem achieves both proximal and distal stability, which resists the micromotion and torsional loads that would otherwise prevent ingrowth. Seventy-three hips were reviewed at a minimum of 10 years' follow-up. Osteolysis was common, occurring in 55% of hips, but no osteolysis distal to th\u00e9 stem\/sleeve junction was present. At mean 12 years' follow-up, the stem remains stable and no failures of the modular junction have been reported.<\/jats:p>","DOI":"10.3928\/0147-7447-20050902-05","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T10:48:48Z","timestamp":1619088528000},"source":"Crossref","is-referenced-by-count":10,"title":["Proximal\/Distal Mismatch: Type A and C Femurs"],"prefix":"10.3928","volume":"28","author":[{"given":"Michael","family":"Christie","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martha F","family":"Brinson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1 . Noble PC. Alexander JW Lindabl LJ et al. The anatomic basis of femoral component design. Clin Orthop. 1988; 235:148-165.","DOI":"10.1097\/00003086-198810000-00015"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Pilliar RM Lee JM Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. CUn Orthop. 1986; 208:108-1 13.","DOI":"10.1097\/00003086-198607000-00023"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Crowninshield RD Johnston RC Andrews JG Brand RA. A biomechanieal investigation of the human hip. J Biomech. 1978; 11:75-85.","DOI":"10.1016\/0021-9290(78)90045-3"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Burke DW O'Connor DO Zalenski EB Jasty M Harris WH. Micromotion of cemented and uncemented femoral components. J Bone Joint Surg Br. 1991; 73:33-37.","DOI":"10.1302\/0301-620X.73B1.1991771"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. OhI MD Whiteside LA McCarthy DS White SE. Torsional fixation of a modular femoral hip component. CUn Orthop. 1993; 287:135-141.","DOI":"10.1097\/00003086-199302000-00022"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Christie MJ DeBoer DK Trick LW et al. Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven-year clinical and radiographic results. J Bone Joint Surg Am. 1999; 81:1707-1716.","DOI":"10.2106\/00004623-199912000-00008"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Engh CA Massin P Suthers KE. Roentgenographs assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop. 1990; 257:107128.","DOI":"10.1097\/00003086-199008000-00022"},{"key":"e_1_3_1_9_1","unstructured":"8. Dorr LD. Optimizing results of total joint arthroplasty. Instr Course Led. 1985; 34:401-404."},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An endtesuH study using a new method of result evaluation. \/ Bone Joint Surg Am. 1969; 51:737-755.","DOI":"10.2106\/00004623-196951040-00012"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Groen TA McNeice GM Amstutz HC. \"Modes of failure\" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop. 1979; 141:17-27.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Engh CA Jr Claus AM Hopper RH Jr Engh CA. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop. 2001; 393:137-146.","DOI":"10.1097\/00003086-200112000-00016"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Hellman EJ Capello WN Feinberg JR. Omnifit cementless total hip arthroplasty. A 10-year average followup. Clin Orthop. 1999;364:164-174.","DOI":"10.1097\/00003086-199907000-00022"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Kim YH Kim JS Cho SH. Primary total hip arthroplasty with a cementless porouscoated anatomic total hip prostesisi 10- to 12-year results of prospective and consecutive series. J Arthroplasty. 1999; 14:538548.","DOI":"10.1016\/S0883-5403(99)90074-8"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T04:59:28Z","timestamp":1683089968000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-20050902-05"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,9,2]]},"references-count":13,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2005,9,2]]}},"alternative-id":["10.3928\/0147-7447-20050902-05"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-20050902-05","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,9,2]]}}}