{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T21:26:36Z","timestamp":1773609996960,"version":"3.50.1"},"reference-count":13,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2005,9,2]]},"abstract":"<jats:p>abstract<\/jats:p>\n          <jats:p>Normal femoral version contributes to the inherent stability of the hip joint. Abnormal version is found in a variety of hip diseases afflicting children and adults. At the time of reconstruction for end-stage hip disease, maintaining proper femoral version in conjunction with acetabular version allows for hip stability and unimpeded functional range of motion. In those instances where femoral version is significantly abnormal, a means of correction at time of surgery is necessary. Non-modular femoral components allow for minor adjustments in version at time of surgery. To accommodate significant versional abnormalities, the modular S-ROM (DePuy Orthopaedics Ine, Warsaw, lnd) was introduced in 1984. In a series of 156 primary S-ROM total hip arthroplasties, the ability to correct for abnormal version resulted in excellent clinical results with no incidence of hip instability and excellent range of motion.<\/jats:p>","DOI":"10.3928\/0147-7447-20050902-08","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T10:48:48Z","timestamp":1619088528000},"source":"Crossref","is-referenced-by-count":6,"title":["Femoral Version: Definition, Diagnosis, and Intraoperative Correction With Modular Femoral Components"],"prefix":"10.3928","volume":"28","author":[{"given":"James C","family":"Kudrna","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Staheli LT. Medial femoral torsion. Orthop Clin North Am. 1980; 11:39-50.","DOI":"10.1016\/S0030-5898(20)31495-4"},{"key":"e_1_3_1_3_1","unstructured":"2. Alvik I. Increased anteversion of the femur as the only manifestation of dysplasia of the hip. Clin Orthop. 1962; 22:16-20."},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Tonnis D Heinecke A. Diminished femoral antetorsion syndrome: a cause of pain and osteoarthritis. J Pediatric Orthop. 1991; 11:419-431.","DOI":"10.1097\/01241398-199107000-00001"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Tonnis D Heinecke A. Acetabular and femoral anteversion: relationship with osteoarthritis of the hip. J Bone Joint Surg Am. 1999; 81:1 7471770.","DOI":"10.2106\/00004623-199912000-00014"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Gelberman RH Cohen MS Shaw BA et al. The association of femoral retroversion with slipped capital femoral epiphysis. J Bone Joint Surg Am. 1986;68:1000-1007.","DOI":"10.2106\/00004623-198668070-00006"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Sugano N Noble PC Karmaric E. A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr. 1998; 22:610-614.","DOI":"10.1097\/00004728-199807000-00019"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Magilligan DJ. Calculation of the angle of anteversion by means of horizontal lateral roentgenography. J Bone Joint Surg Am. 1956; 38:1231-1246.","DOI":"10.2106\/00004623-195638060-00005"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Hubbard DD. Staheli LT. The direct radiographic measurement of femoral torsion using axial tomography: technic comparison with an indirect radiographie method. Clin Orthop. 1972:86:16-20.","DOI":"10.1097\/00003086-197207000-00004"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Starker M1 Hanusek S Rittmeister M Thoma W. Validation of computerized tomography antetorsion angle measurement of the femur. Z Orthop Iher Grenzgeb. 1998; 136:420-427.","DOI":"10.1055\/s-2008-1053678"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. LaGasse DJ Staheli LT. The measurement of femoral anteversion: a comparison of the fluoroscope and biplane roetgenograpbic methods of measurement. Clin Orthop. 1972;86:13-15.","DOI":"10.1097\/00003086-197207000-00003"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Christie MJ. DeBoer DK Trick LW et al. Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven year clinical and radiographic results. J Bone Joint Surg Am. 1999;81:1707-1716.","DOI":"10.2106\/00004623-199912000-00008"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Andress HJ Kahl S Kranz C Gierer P. Schurmann M Lob G. Clinical and finite element analysis of a modular femoral prosthesis consisting of a head and stem component in the treatment of pertrochanteric fractures. J Orthop Trauma. 2000; 14:546-553.","DOI":"10.1097\/00005131-200011000-00005"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Cameron HU. The 3-6 year results of a modular noncemented low-bending stiffness hip implant. A preliminary study. J Arthroplasty. 1993: 8:239-243","DOI":"10.1016\/S0883-5403(06)80084-7"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T05:00:45Z","timestamp":1683090045000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0147-7447-20050902-08"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,9,2]]},"references-count":13,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2005,9,2]]}},"alternative-id":["10.3928\/0147-7447-20050902-08"],"URL":"https:\/\/doi.org\/10.3928\/0147-7447-20050902-08","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,9,2]]}}}