{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T02:52:51Z","timestamp":1775703171667,"version":"3.50.1"},"reference-count":29,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2010,11,2]]},"abstract":"<jats:p>We analyzed the long-term results of a single-surgeon series of 102 cementless total hip arthroplasties (THAs) performed using a sandwich-type alumina ceramic bearing. The prostheses involved a porous-coated acetabular socket, a polyethylene-alumina composite liner, a 28-mm alumina head, and a grit-blasted titanium-alloy stem. Mean patient age at the time of THA was 39 years (range, 18\u201366 years), and 76% of the patients were younger than 50 years. All procedures were performed with use of the same surgical technique and the same implant at a single center. Mean follow-up was 115 months (range, 84\u2013133 months).<\/jats:p>\n          <jats:p>When failure was defined as revision of either the acetabular or the femoral component for any reason, Kaplan-Meier survival probability at 10 years was 95.3% (95% confidence interval, 89.5%\u2013100%). Mean Harris Hip Score improved from 47 points (range, 16\u201370 points) preoperatively to 95 points (range, 85\u2013100 points) at final follow-up. No radiographically detectable osteolysis around the acetabular or femoral component was observed in any hip. No patient reported squeaking in the operated hip. During the follow-up period, 3 hips (3%) required revision surgery; 2 underwent acetabular revision because of a ceramic liner fracture and 1 underwent revision for early loosening of the acetabular cup.<\/jats:p>\n          <jats:p>Ten-year results of cementless THA with a sandwich-type alumina ceramic bearing were encouraging, and no great increase in ceramic failure rate was observed, which contrasts with the findings of previously reported short-term follow-up studies.<\/jats:p>","DOI":"10.3928\/01477447-20100924-11","type":"journal-article","created":{"date-parts":[[2010,11,5]],"date-time":"2010-11-05T15:11:13Z","timestamp":1288969873000},"page":"1-5","source":"Crossref","is-referenced-by-count":17,"title":["Ten-Year Results After Cementless THA with a Sandwich-Type Alumina Ceramic Bearing"],"prefix":"10.3928","volume":"33","author":[{"given":"Youn-Soo","family":"Park","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Se-Jun","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seung-Jae","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.32183"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200212000-00019"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.86B2.14026"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.01466"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.I.01019"},{"issue":"417","key":"e_1_3_1_7_2","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/01.blo.0000096806.78689.50","article-title":"Fractures of ceramic bearings: history and present status","author":"Hannouche D","year":"2003","unstructured":"Hannouche D, Nich C, Bizot P, Meunier A, Nizard R, Sedel L. Fractures of ceramic bearings: history and present status. Clin Orthop Relat Res. 2003; (417):19\u201326.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.01489"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20080801-07"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-001-0378-z"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(03)00193-1"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-008-0168-9"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B7.17675"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.E.00618"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196951040-00012"},{"issue":"141","key":"e_1_3_1_16_2","first-page":"17","article-title":"\u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening","author":"Gruen TA","year":"1979","unstructured":"Gruen TA, McNeice GM, Amstutz HC. \u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979; (141):17\u201327.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.80B4.7361"},{"issue":"257","key":"e_1_3_1_18_2","first-page":"107","article-title":"Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components","author":"Engh CA","year":"1990","unstructured":"Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990; (257):107\u2013128.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B1.1732268"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198264090-00004"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2003.10.016"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199607000-00001"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197355080-00006"},{"issue":"5","key":"e_1_3_1_24_2","first-page":"1132","article-title":"Failure mechanism of ceramic total hip arthroplasty\u2014reply","volume":"89","author":"Park YS","year":"2007","unstructured":"Park YS, Moon YW, Lim SJ. Failure mechanism of ceramic total hip arthroplasty\u2014reply. J Bone Joint Surg Am. 2007; 89(5):1132\u20131133.","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.06.018"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-008-0177-8"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00970"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.01326"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B9.19282"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00867"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/orthopedics\/hip\/journals\/ortho\/2010-11-33-11\/%7B3d5b107b-a90c-4b7a-807c-7611d671fbf4%7D\/ten-year-results-after-cementless-tha-with-a-sandwich-type-alumina-ceramic-bearing","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T00:39:18Z","timestamp":1683074358000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20100924-11"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11,2]]},"references-count":29,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2010,11,2]]}},"alternative-id":["10.3928\/01477447-20100924-11"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20100924-11","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,11,2]]}}}