{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T12:11:10Z","timestamp":1683115870841},"reference-count":30,"publisher":"SLACK, Inc.","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2012,12]]},"abstract":"<jats:p>Implants currently used for reconstruction of a burst vertebral body are associated with complications, including subsidence, nonunion, and substantial intraoperative blood loss. A new reconstruction device, the U-Cage (Double Engine Medical Material Ltd, Xiamen, Fujian, China), was designed to minimize complications.<\/jats:p>\n          <jats:p>\n            Six intact adult cadaver thoracolumbar (T11-L3) spines were collected and scanned by dual-energy X-ray absorptiometry (DEXA). The stiffness of the burst spine was subsequently compared with its previous intact state during flexion\/extension, lateral bending, and rotation, and then subjected to a cyclic test to predict cage subsidence and device loosening. Axial load was applied continuously until failure to test the peak load that the specimen could withstand during the cyclic test. The correlation of bone mineral density and peak load was also analyzed. The instrumented specimens were found to be equivalent to intact bone in all directions (\n            <jats:italic>P<\/jats:italic>\n            &gt;.05), with the exception of left rotation (\n            <jats:italic>P<\/jats:italic>\n            &lt;.05). All specimens could withstand the cyclic test, and no subsidence or loosening of the device was detected. Average peak load for the instrumented specimens was 4137.5 N, which correlated with the average bone mineral density (\n            <jats:italic>r<\/jats:italic>\n            =0.915;\n            <jats:italic>P<\/jats:italic>\n            =.011).\n          <\/jats:p>\n          <jats:p>Thoracolumbar burst fractures instrumented with a U-Cage and anterolateral D-rod fixation achieved a stiffness similar to that of intact spines. This procedure may avoid the subsidence of the cage in vivo and serve as a better option for treating thoracolumbar burst fractures.<\/jats:p>","DOI":"10.3928\/01477447-20121120-25","type":"journal-article","created":{"date-parts":[[2012,12,5]],"date-time":"2012-12-05T22:59:34Z","timestamp":1354748374000},"source":"Crossref","is-referenced-by-count":2,"title":["Design and Biomechanical Properties of a New Reconstruction Device for Treating Thoracolumbar Burst Fractures"],"prefix":"10.3928","volume":"35","author":[{"given":"Bowei","family":"Liang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenqi","family":"Ding","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tieqi","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liangqi","family":"Kang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenliang","family":"Zai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mo","family":"Sha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xigui","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000325260.00628.DC"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.BRS.0000058712.88053.13"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-006-0284-8"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.bsd.0000132287.65702.8a"},{"issue":"1","key":"e_1_3_1_6_2","first-page":"49","article-title":"Anterior decompression and fixation versus posterior reposition and semirigid fixation in the treatment of unstable burst thoracolumbar fracture: prospective clinical trial","volume":"42","author":"Stanci M","year":"2001","unstructured":"Stanci M, Gregorovi E, Nozica E, Penezi L. Anterior decompression and fixation versus posterior reposition and semirigid fixation in the treatment of unstable burst thoracolumbar fracture: prospective clinical trial. Croat Med J. 2001; 42(1):49\u201353.","journal-title":"Croat Med J"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2010.08.017"},{"issue":"128","key":"e_1_3_1_8_2","first-page":"78","article-title":"Traumatic kyphosis of the thoracolumbar spine","author":"Whitesides TE","year":"1977","unstructured":"Whitesides TE. Traumatic kyphosis of the thoracolumbar spine. Clin Orthop Relat Res. 1977; (128):78\u201392.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_1_9_2","first-page":"459","article-title":"Anterior or posterior stabilisation following corpectomy for unstable thoracolumbar burst fractures: a biomechanical study","volume":"90","author":"Dillon D","year":"2008","unstructured":"Dillon D, Jones A, Ahuja S, et al. Anterior or posterior stabilisation following corpectomy for unstable thoracolumbar burst fractures: a biomechanical study. J Bone Joint Surg Br. 2008; 90(suppl III):459\u2013459.","journal-title":"J Bone Joint Surg Br"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e31807a2f61"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002517-200004000-00010"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000370200.74098.CC"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.BRS.0000129895.90939.1E"},{"key":"e_1_3_1_14_2","first-page":"435","article-title":"Expandable cage for cervical spine reconstruction","volume":"38","author":"Zhang HY","year":"2005","unstructured":"Zhang HY, Thongtrangan I, Le H, Park J, Kim DH. Expandable cage for cervical spine reconstruction. J Korean Neurosurg Soc. 2005; 38:435\u2013441.","journal-title":"J Korean Neurosurg Soc"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181722d52"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2009.09.010"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2008.11.012"},{"issue":"4","key":"e_1_3_1_18_2","first-page":"341","article-title":"Biomechanical comparison of three fixation techniques for unstable thoracolumbar burst fractures","volume":"8","author":"Acosta FL","year":"2008","unstructured":"Acosta FL, Buckley JM, Xu Z, Lotz JC, Ames CP. Biomechanical comparison of three fixation techniques for unstable thoracolumbar burst fractures. J Neurosurg Pediatr. 2008; 8(4):341\u2013346.","journal-title":"J Neurosurg Pediatr"},{"issue":"5","key":"e_1_3_1_19_2","first-page":"442","article-title":"The biomechanical effectiveness of prophylactic vertebroplasty: a dynamic cadaveric study","volume":"8","author":"Oakland RJ","year":"2008","unstructured":"Oakland RJ, Furtado NR, Wilcox RK, Timothy J, Hall RM. The biomechanical effectiveness of prophylactic vertebroplasty: a dynamic cadaveric study. J Neurosurg Pediatr. 2008; 8(5):442\u2013449.","journal-title":"J Neurosurg Pediatr"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200011010-00008"},{"issue":"4","key":"e_1_3_1_21_2","first-page":"201","article-title":"Finite element analysis of cage subsidence in cervical interbody fusion","volume":"24","author":"Chiang MF","year":"2004","unstructured":"Chiang MF, Teng JM, Huang CH, et al. Finite element analysis of cage subsidence in cervical interbody fusion. J Med Biological Engineering. 2004; 24(4):201\u2013208.","journal-title":"J Med Biological Engineering"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e31820ef778"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000155419.24198.35"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000143623.18098.e5"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-002-0505-8"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000181053.38677.c2"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200104150-00022"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-009-0823-y"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2008.10.048"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-011-1284-7"},{"key":"e_1_3_1_31_2","doi-asserted-by":"publisher","DOI":"10.1007\/s005860000211"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/01477447-20121120-25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:44:45Z","timestamp":1683114285000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20121120-25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12]]},"references-count":30,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["10.3928\/01477447-20121120-25"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20121120-25","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,12]]}}}