{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:03:54Z","timestamp":1763017434583},"reference-count":33,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2014,4]]},"abstract":"<jats:p>Intramedullary titanium elastic nails have been reported to fix displaced midclavicular fractures with excellent functional outcomes and minor complications. This study reports and analyzes the complications and technical pitfalls associated with titanium elastic nail fixation of displaced midclavicular fractures and describes how to prevent these problems. The authors operated on 27 patients (17 men, 10 women; mean age, 45.8 years; range, 16.5\u201366.9 years) with marked displaced midclavicular fractures using intramedullary titanium elastic nail fixation. The mean Constant score and Disability of the Arm, Shoulder, and Hand score were 93.58 (range, 66.5\u2013100) and 6.22 (range, 0\u201335), respectively. The mean length difference compared with the contralateral clavicle was a shortening of 0.3 cm (range, \u22121.5 to 1 cm). Eight patients (30%) had different levels of difficulty at the medial entry point. Clavicular length shortening of more than 1 cm occurred in 5 patients (19%), and all of these patients experienced medial nail tip prominence\/protrusion. One patient had 1-cm lengthening of the injured clavicle caused by distraction of the fracture site during titanium elastic nail insertion. Iatrogenic perforation of the posterolateral cortex occurred in 3 patients. Initial misplaced nail insertion occurred in 1 woman who underwent revision with the mini-open method. In 2 patients it was impossible to remove the full nail under general anesthesia. In conclusion, high patient satisfaction and functional outcomes were achieved after titanium elastic nail fixation of displaced midclavicular fractures. However, some complications and technical pitfalls must be considered before titanium elastic nails are used to fix displaced midclavicular fractures.<\/jats:p>","DOI":"10.3928\/01477447-20140401-60","type":"journal-article","created":{"date-parts":[[2014,8,19]],"date-time":"2014-08-19T22:22:26Z","timestamp":1408486946000},"source":"Crossref","is-referenced-by-count":15,"title":["Complications and Technical Pitfalls of Titanium Elastic Nail Fixation for Midclavicular Fractures"],"prefix":"10.3928","volume":"37","author":[{"given":"Cheng-Chang","family":"Lu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ping-Cheng","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shih-Hao","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chih-Hsin","family":"Hsieh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yin-Chun","family":"Tien","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Song-Hsiung","family":"Chien","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1067\/mse.2002.126613"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1080\/000164702753671696"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.79B4.7529"},{"key":"e_1_3_2_5_2","first-page":"1106","volume-title":"Rockwood and Green\u2019s Fractures in Adults","author":"McKee MD","year":"2010","unstructured":"McKee MD. Clavicle fractures. In: , Bucholz RW, Heckman JD, Court-Brown CM, Tornetta P, eds. Rockwood and Green\u2019s Fractures in Adults, 7th ed. Vol. 1. Philadelphia, PA: Lippincott Williams & Wilkins; 2010:1106\u20131143.","edition":"7"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199711000-00008"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000183088.60639.05"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1607-551X(08)70073-1"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199208000-00003"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(99)00140-0"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00020"},{"key":"e_1_3_2_12_2","first-page":"283","article-title":"The treatment of nonunion fractures of the midshaft of the clavicle with an intramedullary Hagie pin and autogenous bone graft","volume":"42","author":"Boehme D","year":"1993","unstructured":"Boehme D, Curtis RJ, DeHaan JT, Kay SP, Young DC, Rockwood CA. The treatment of nonunion fractures of the midshaft of the clavicle with an intramedullary Hagie pin and autogenous bone graft. Instr Course Lect. 1993; 42:283\u2013290.","journal-title":"Instr Course Lect"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199404000-00002"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453679909000991"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016470308540853"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20071101-13"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.80B1.7880"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPB.0b013e3282f103c4"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/01241398-200101000-00003"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2005.05.012"},{"issue":"6","key":"e_1_3_2_21_2","first-page":"511","article-title":"Technique of intramedullary osteosynthesis of the clavicle with elastic titanium nails [in German]","volume":"105","author":"Jubel A","year":"2002","unstructured":"Jubel A, Andermahr J, Schiffer G, Rehm KE. Technique of intramedullary osteosynthesis of the clavicle with elastic titanium nails [in German]. Unfallchirurg. 2002; 105(6):511\u2013516.","journal-title":"Unfallchirurg"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200303000-00037"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjsm.37.6.480"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1080\/17453670710014022"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1080\/17453670710014013"},{"issue":"3","key":"e_1_3_2_26_2","first-page":"269","article-title":"Elastic stable intramedullary nailing for midclavicular fractures in athletes: indications, technical pitfalls and early results","volume":"72","author":"Meier C","year":"2006","unstructured":"Meier C, Grueninger P, Platz A. Elastic stable intramedullary nailing for midclavicular fractures in athletes: indications, technical pitfalls and early results. Acta Orthop Belg. 2006; 72(3):269\u2013275.","journal-title":"Acta Orthop Belg"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00113-005-1029-6"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.01336"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198701000-00023"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-1130(01)80043-0"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508328103"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1002\/ca.20269"},{"issue":"3","key":"e_1_3_2_33_2","first-page":"96","article-title":"Removal torques of small screws of steel and titanium with different surfaces [in German]","volume":"93","author":"Eulenberger J","year":"1990","unstructured":"Eulenberger J, Steinemann SG. Removal torques of small screws of steel and titanium with different surfaces [in German]. Unfallchirurg. 1990; 93(3):96\u201399.","journal-title":"Unfallchirurg"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453679809000938"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/01477447-20140401-60","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T08:24:15Z","timestamp":1683102255000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20140401-60"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4]]},"references-count":33,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,4]]}},"alternative-id":["10.3928\/01477447-20140401-60"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20140401-60","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,4]]}}}