{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T20:02:38Z","timestamp":1762459358697},"reference-count":50,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2016,3]]},"abstract":"<jats:p>\n            The survivorship of total hip arthroplasty in younger patients is dependent on the wear characteristics of the bearing surfaces. Long-term results with conventional polyethylene in young patients show a high failure rate. This study assessed the long-term results of a first-generation annealed highly cross-linked polyethylene (HCLPE) in uncemented total hip arthroplasty in young, active patients. Between 1999 and 2003, 112 total hip arthroplasty procedures performed in 91 patients with an average University of California Los Angeles activity score of 8 and mean age of 53 years (range, 24\u201365 years) were included from a prospective database. In all patients, a 28-mm metal femoral head on annealed HCLPE (Crossfire; Stryker, Mahwah, New Jersey) was used. At minimum 10-year follow-up (11.5\u00b10.94 years), Kaplan-Meier survivorship was 97% for all failures (1 periprosthetic infection and 1 late dislocation) and 100% for mechanical failure (no revisions for osteolysis or loosening). This study showed low revision rates for wear-related failure and superior survivorship in young, active patients. Oxidation causing failure of the locking mechanism has not been a problem with Crossfire for up to 10 years. [\n            <jats:italic>Orthopedics.<\/jats:italic>\n            2016; 39(2):e225\u2013e229.]\n          <\/jats:p>","DOI":"10.3928\/01477447-20160119-02","type":"journal-article","created":{"date-parts":[[2016,1,26]],"date-time":"2016-01-26T14:40:21Z","timestamp":1453819221000},"source":"Crossref","is-referenced-by-count":16,"title":["Long-term Results of a First-Generation Annealed Highly Cross-Linked Polyethylene in Young, Active Patients"],"prefix":"10.3928","volume":"39","author":[{"given":"Chitranjan S.","family":"Ranawat","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amar S.","family":"Ranawat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alankar A.","family":"Ramteke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danyal","family":"Nawabi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Morteza","family":"Meftah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-011-1872-4"},{"key":"e_1_3_1_3_2","unstructured":"Australian Orthopaedic Association National Joint Replacement Registry. Hip and knee arthroplasty: annual report 2013. https:\/\/aoanjrr.dmac.adelaide.edu.au\/annual-reports-2013. Accessed October 2013."},{"key":"e_1_3_1_4_2","unstructured":"Swedish Joint Registry. Annual report 2013. http:\/\/myknee.se\/pdf\/SKAR2013_Eng.pdf. Accessed September 2013."},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocl.2012.05.008"},{"key":"e_1_3_1_6_2","unstructured":"National Joint Registry for England Wales and Northern Ireland. 10th annual report: 2013. http:\/\/www.njrcentre.org.uk\/njrcentre\/Portals\/0\/Documents\/England\/Reports\/10th_annual_report\/NJR%2010th%20Annual%20Report%202013%20B.pdf. Accessed October 2014."},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000149821.72760.39"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199311000-00006"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0883-5403(94)90090-6"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199607000-00003"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2009.05.010"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2010.02.013"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.09.015"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.00043"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-013-2036-9"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.01211"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-009-0878-y"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.00432"},{"issue":"12","key":"e_1_3_1_19_2","first-page":"1833","article-title":"Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee","volume":"15","author":"Bellamy N","year":"1988","unstructured":"Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988; 15(12):1833\u20131840.","journal-title":"J Rheumatol"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2011.07.014"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-008-0358-5"},{"issue":"2","key":"e_1_3_1_22_2","first-page":"179","article-title":"Ante- and retroversion measurements of cups by EBRA","volume":"83","author":"Stoeckl B","year":"2001","unstructured":"Stoeckl B, Biedermann R, Auckenthaler T, Bach C, Sununu T, Nogler M. Ante- and retroversion measurements of cups by EBRA. J Bone Joint Surg Br. 2001; 83(suppl 2):179.","journal-title":"J Bone Joint Surg Br"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2011.652889"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00336"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2009.04.022"},{"key":"e_1_3_1_26_2","unstructured":"US Food and Drug Administration. 2012 meeting materials of the Orthopaedic and Rehabilitation Devices Panel. http:\/\/www.fda.gov\/AdvisoryCommittees\/CommitteesMeetingMaterials\/MedicalDevices\/MedicalDevicesAdvisoryCommittee\/OrthopaedicandRehabilitationDevicesPanel\/ucm309184.htm. Accessed February 17 2013."},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20090728-06"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-012-1502-0"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.e2663"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-010-1148-8"},{"key":"e_1_3_1_31_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.92B1.21530"},{"key":"e_1_3_1_32_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-1091-4"},{"key":"e_1_3_1_33_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.I.01019"},{"key":"e_1_3_1_34_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00970"},{"key":"e_1_3_1_35_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200512000-00024"},{"key":"e_1_3_1_36_2","first-page":"319","article-title":"Cross-linked vs conventional polyethylene in bilateral hybrid THA: randomized RSA study","volume":"29","author":"Digas G","year":"2004","unstructured":"Digas G, Herberts P, Karrholm J, et al. Cross-linked vs conventional polyethylene in bilateral hybrid THA: randomized RSA study. Trans Orthop Res Soc. 2004; 29:319.","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_3_1_37_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.D.01915"},{"key":"e_1_3_1_38_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200404000-00012"},{"key":"e_1_3_1_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2013.07.034"},{"key":"e_1_3_1_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2012.12.020"},{"key":"e_1_3_1_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2012.01.006"},{"issue":"2","key":"e_1_3_1_42_2","first-page":"181","article-title":"Alumina on alumina versus metal on conventional polyethylene: a randomized clinical trial with 9 to 15 years follow-up","volume":"79","author":"Vendittoli PA","year":"2013","unstructured":"Vendittoli PA, Riviere C, Lavigne M, Lavoie P, Alghamdi A, Duval N. Alumina on alumina versus metal on conventional polyethylene: a randomized clinical trial with 9 to 15 years follow-up. Acta Orthop Belg. 2013, 79(2):181\u2013190.","journal-title":"Acta Orthop Belg"},{"key":"e_1_3_1_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2011.08.017"},{"key":"e_1_3_1_44_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.I.01644"},{"key":"e_1_3_1_45_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-011-2076-7"},{"key":"e_1_3_1_46_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.I.01715"},{"key":"e_1_3_1_47_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.94B3.28185"},{"key":"e_1_3_1_48_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-012-2493-2"},{"key":"e_1_3_1_49_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-011-1399-z"},{"key":"e_1_3_1_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2011.02.020"},{"key":"e_1_3_1_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2012.12.005"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/orthopedics\/journals\/ortho\/2016-3-39-2\/%7B77738993-70d4-4f9c-a74f-5a053dbebafd%7D\/long-term-results-of-a-first-generation-annealed-highly-cross-linked-polyethylene-in-young-active-patients","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T06:05:08Z","timestamp":1683093908000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20160119-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3]]},"references-count":50,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["10.3928\/01477447-20160119-02"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20160119-02","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,3]]}}}