{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:16:14Z","timestamp":1762866974732},"reference-count":13,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:p>\n            Rupture of the flexor pollicis longus tendon is a major complication after volar locking plate fixation of distal radius fracture. This study used ultrasonography to assess the flexor pollicis longus tendon and intermediate tissue. The study assessed 27 patients (28 wrists) who underwent removal of the volar locking plate. Before plate removal, radiography and ultrasonography were performed to assess the relation between the flexor pollicis longus tendon and the volar locking plate. Intraoperatively, the authors evaluated the intermediate tissues between the flexor pollicis longus tendon and the distal volar margin of the plate. Preoperative and intraoperative findings were compared. Intraoperative findings were strongly related to the distance between the flexor pollicis longus tendon and the volar locking plate on ultrasonography. The sensitivity of ultrasonography in detecting thin, membrane-like intermediate tissue through which the plate was visible was 95%, and the specificity was 89% if the distance between the flexor pollicis longus tendon and the plate was less than 0.7 mm. Compression of the flexor pollicis longus tendon was seen in 11 cases (39.3%), and this finding suggested the presence of thin, membrane-like intermediate tissue. The study results showed that ultrasonography could be used to identify the type of intermediate tissue between the flexor pollicis longus tendon and the volar locking plate. [\n            <jats:italic>Orthopedics.<\/jats:italic>\n            2017; 40(1):e104\u2013e108.]\n          <\/jats:p>","DOI":"10.3928\/01477447-20161017-01","type":"journal-article","created":{"date-parts":[[2016,10,26]],"date-time":"2016-10-26T17:57:01Z","timestamp":1477504621000},"source":"Crossref","is-referenced-by-count":10,"title":["Ultrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation"],"prefix":"10.3928","volume":"40","author":[{"given":"Chieko","family":"Kadoma","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masatoshi","family":"Takahara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Maruyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Satake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michiaki","family":"Takagi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1142\/S0218810400000223"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B3.8175841"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2011.02.005"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2010.09.033"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.3109\/03009734.2011.594183"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-002-0393-x"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11552-009-9180-0"},{"issue":"2","key":"e_1_3_1_9_2","first-page":"70","article-title":"Evaluation of flexor pollicis longus tendon rupture after volar locking plate fixation of distal radius fractures by ultrasonography [in Japanese]","volume":"27","author":"Dohi D","year":"2010","unstructured":"Dohi D. Evaluation of flexor pollicis longus tendon rupture after volar locking plate fixation of distal radius fractures by ultrasonography [in Japanese]. J Jpn Soc Surg Hand. 2010; 27(2):70\u201373.","journal-title":"J Jpn Soc Surg Hand"},{"issue":"1","key":"e_1_3_1_10_2","first-page":"25","article-title":"Ultrasonographic study of flexor pollicis longus tendon after volar locking plate fixation in the treatment of fractures of the distal radius [in Japanese]","volume":"34","author":"Kameyama M","year":"2012","unstructured":"Kameyama M, Takeda K, Komiyama T, et al. Ultrasonographic study of flexor pollicis longus tendon after volar locking plate fixation in the treatment of fractures of the distal radius [in Japanese]. J Jpn Soc Fracture Repair. 2012; 34(1):25\u201327.","journal-title":"J Jpn Soc Fracture Repair"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2012.06.041"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.00193"},{"key":"e_1_3_1_13_2","first-page":"e43","article-title":"Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: pronator quadratus plate coverage may not adequately protect tendons","volume":"11","author":"Brown EN","year":"2011","unstructured":"Brown EN, Lifchez SD. Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: pronator quadratus plate coverage may not adequately protect tendons. ePlasty. 2011; 11:e43.","journal-title":"ePlasty"},{"issue":"3","key":"e_1_3_1_14_2","first-page":"140","article-title":"Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study","volume":"34","author":"Douthit JD","year":"2005","unstructured":"Douthit JD. Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study. Am J Orthop (Belle Mead NJ). 2005; 34(3):140\u2013147.","journal-title":"Am J Orthop (Belle Mead NJ)"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/orthopedics\/journals\/ortho\/2017-1-40-1\/%7Bd8a19240-c7ef-4699-a46e-eaca38365c6a%7D\/ultrasonographic-assessment-of-the-flexor-pollicis-longus-tendon-after-plate-fixation","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T08:30:21Z","timestamp":1683102621000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20161017-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["10.3928\/01477447-20161017-01"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20161017-01","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1]]}}}