{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T18:46:07Z","timestamp":1775933167995,"version":"3.50.1"},"reference-count":32,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2017,11]]},"abstract":"<jats:p>\n            This study was conducted to determine whether proximal humerus fracture patterns as defined by the Orthopaedic Trauma Association (AO\/OTA) classification and the Neer 4-part system predicted functional outcomes for patients treated with open reduction and internal fixation with locked plates and, if so, which system correlated better with outcomes. During a 12-year period, 213 patients with a displaced proximal humerus fracture who underwent surgical treatment with a locking plate at 1 academic institution were prospectively followed. All patients were treated in a similar way and were followed by the operating surgeon at routine intervals. Functional outcomes were measured with the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire. Of these patients, 164 were available for analysis. Functional outcomes based on DASH scores did not differ significantly by Neer system, AO\/OTA classification, or varus\/valgus humeral head alignment at more than 12 months postoperatively. However, patients with Neer 4-part fracture and AO\/OTA type 11-C fracture had worse shoulder range of motion in terms of forward elevation and external rotation. Time to healing and complication rates also were not significantly different based on either classification system. Fracture classification can predict shoulder range of motion 12 months after surgical fixation, but its use is limited in predicting functional outcome scores, time to healing, and complication rates. Patients who undergo surgical repair of a proximal humerus fracture can expect good functional results independent of the initial injury pattern, but more severe fracture patterns may lead to decreased shoulder range of motion. [\n            <jats:italic>Orthopedics.<\/jats:italic>\n            2017; 40(6):368\u2013374.]\n          <\/jats:p>","DOI":"10.3928\/01477447-20170925-04","type":"journal-article","created":{"date-parts":[[2017,10,2]],"date-time":"2017-10-02T19:32:49Z","timestamp":1506972769000},"page":"368-374","source":"Crossref","is-referenced-by-count":14,"title":["Fracture Severity Based on Classification Does Not Predict Outcome Following Proximal Humerus Fracture"],"prefix":"10.3928","volume":"40","author":[{"given":"Nina D.","family":"Fisher","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James M.","family":"Barger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adam S.","family":"Driesman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rebekah","family":"Belayneh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanjit R.","family":"Konda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth A.","family":"Egol","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00001648-199611000-00008"},{"issue":"2","key":"e_1_3_1_3_2","first-page":"54","article-title":"Open reduction internal fixation for proximal humerus fractures: indications, techniques, and pitfalls","volume":"71","author":"Shulman BS","year":"2013","unstructured":"Shulman BS, Egol KA. Open reduction internal fixation for proximal humerus fractures: indications, techniques, and pitfalls. Bull Hosp Jt Dis (2013). 2013; 71(suppl 2):54\u201359.","journal-title":"Bull Hosp Jt Dis (2013)"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2007.06.025"},{"issue":"12","key":"e_1_3_1_5_2","first-page":"CD000434","article-title":"Interventions for treating proximal humeral fractures in adults","author":"Handoll HH","year":"2012","unstructured":"Handoll HH, Ollivere BJ, Rollins KE. Interventions for treating proximal humeral fractures in adults. Cochrane Database Syst Rev. 2012; 12:CD000434.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2011.04.003"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.TA.0000170400.68994.AB"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2015.1629"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.bot.0000244997.52751.58"},{"issue":"3","key":"e_1_3_1_10_2","first-page":"212","article-title":"Similar function and improved range of shoulder motion is achieved following repair of three- and four-part proximal humerus fractures compared with hemiarthroplasty","volume":"74","author":"Khurana S","year":"2016","unstructured":"Khurana S, Davidovitch RI, Kwon YK, Zuckerman JD, Egol KA. Similar function and improved range of shoulder motion is achieved following repair of three- and four-part proximal humerus fractures compared with hemiarthroplasty. Bull Hosp Jt Dis (2013). 2016; 74(3):212\u2013218.","journal-title":"Bull Hosp Jt Dis (2013)"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/1756-0500-6-69"},{"key":"e_1_3_1_12_2","volume-title":"The Shoulder; Rupture of the Supraspinatus Tendon and Other Lesions in or About the Subacromial Bursa","author":"Codman EA.","year":"1934","unstructured":"Codman EA. The Shoulder; Rupture of the Supraspinatus Tendon and Other Lesions in or About the Subacromial Bursa. Boston, MA: T. Todd Company; 1934."},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197052060-00001"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-011-0916-5"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200711101-00001"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2016.01.021"},{"issue":"9","key":"e_1_3_1_17_2","first-page":"407","article-title":"Outcomes of open reduction and internal fixation of proximal humerus fractures managed with locking plates","volume":"41","author":"Ong CC","year":"2012","unstructured":"Ong CC, Kwon YW, Walsh M, Davidovitch R, Zuckerman JD, Egol KA. Outcomes of open reduction and internal fixation of proximal humerus fractures managed with locking plates. Am J Orthop (Belle Mead NJ). 2012; 41(9):407\u2013412.","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2013.11.009"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-008-0325-6"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(97)90072-0"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199312000-00003"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016470412331294445"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2015.08.006"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2016.11.047"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31819344bf"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-5-60"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e3181920e5b"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000252"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2011.06.009"},{"key":"e_1_3_1_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2004.01.034"},{"key":"e_1_3_1_32_2","doi-asserted-by":"publisher","DOI":"10.3928\/0147-7447-20040201-13"},{"key":"e_1_3_1_33_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-009-0975-9"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.healio.com\/doiresolver?doi=10.3928\/01477447-20170925-04","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T12:18:36Z","timestamp":1683116316000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20170925-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["10.3928\/01477447-20170925-04"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20170925-04","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11]]}}}