{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T07:12:52Z","timestamp":1792653172757,"version":"4.5.0"},"reference-count":28,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:p>\n                    The primary purpose of this study was to describe the failure patterns of femoral neck fracture fixation in young patients. The secondary purpose was to determine if pattern of failure varies by type of implant. Adult patients (age range, 18\u201355 years) who experienced a \u201cfixation failure\u201d following internal fixation of a femoral neck fracture were identified from 5 level 1 trauma centers. Failure was defined by screw cutout, implant breakage, varus collapse (&lt;120\u00b0 neck-shaft angle), or severe fracture shortening (\u22651 cm). When multiple complications were identified, mechanical failures were preferentially noted for the analysis. Failure patterns were compared between patients who received multiple cancellous screws and patients who received a sliding hip screw plus a derotation screw. Severe fracture shortening was the most common complication identified (61%). No differences in the incidence of severe shortening (\n                    <jats:italic>P<\/jats:italic>\n                    =.750) or implant breakage (\n                    <jats:italic>P<\/jats:italic>\n                    =1.000) were detected between the fixation groups. However, among the failures with a sliding hip screw plus a derotation screw construct, a greater portion were related to screw cutout (38% for a sliding hip screw plus a derotation screw vs 7% for screws,\n                    <jats:italic>P<\/jats:italic>\n                    =.019). Failures with multiple screws were associated with varus collapse (25% for screws vs 0% for a sliding hip screw plus a derotation screw,\n                    <jats:italic>P<\/jats:italic>\n                    =.037). Severe shortening was the most common fixation failure. Sliding hip screw plus derotation screw implants were associated with screw cutout. Multiple cancellous screw implants failed by varus collapse. Selecting a surgical implant based on its likely failure pattern may allow surgeons to minimize the severity of failure or the need for secondary conversion to hip arthroplasty. [\n                    <jats:italic>Orthopedics.<\/jats:italic>\n                    2019; 42(4):e376\u2013e380.]\n                  <\/jats:p>","DOI":"10.3928\/01477447-20190321-03","type":"journal-article","created":{"date-parts":[[2019,3,26]],"date-time":"2019-03-26T15:12:26Z","timestamp":1553613146000},"source":"Crossref","is-referenced-by-count":30,"title":["Failure Patterns of Femoral Neck Fracture Fixation in Young Patients"],"prefix":"10.3928","volume":"42","author":[{"given":"David J.","family":"Stockton","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karan","family":"Dua","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J.","family":"O'Brien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew N.","family":"Pollak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. Max","family":"Hoshino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerard P.","family":"Slobogean","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.10.010"},{"issue":"10","key":"e_1_3_1_3_2","first-page":"2254","article-title":"Treatment of femoral neck fractures in young adults","volume":"90","author":"Ly TV","year":"2008","unstructured":"Ly TV, Swiontkowski MF. Treatment of femoral neck fractures in young adults. J Bone Joint Surg Am. 2008;90(10):2254\u20132266.","journal-title":"J Bone Joint Surg Am"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.11.028"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B11.20582"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2017.06.013"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000351"},{"issue":"1","key":"e_1_3_1_8_2","first-page":"131","article-title":"Complications after intracapsular hip fractures in young adults: a meta-analysis of 18 published studies involving 564 fractures","volume":"36","author":"Damany DS","year":"2005","unstructured":"Damany DS, Parker MJ, Chojnowski A. Complications after intracapsular hip fractures in young adults: a meta-analysis of 18 published studies involving 564 fractures. Injury. 2005;36(1):131\u2013141.","journal-title":"Injury"},{"issue":"4","key":"e_1_3_1_9_2","first-page":"CD001467","article-title":"Internal fixation implants for intracapsular proximal femoral fractures in adults","author":"Parker MJ","year":"2001","unstructured":"Parker MJ, Stockton G. Internal fixation implants for intracapsular proximal femoral fractures in adults. Cochrane Database Syst Rev. 2001;(4):CD001467.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.43B4.647"},{"key":"e_1_3_1_11_2","first-page":"1","article-title":"Der schenkelhalsbruch ein mechanisches problem","volume":"63","author":"Pauwels F","year":"1935","unstructured":"Pauwels F. Der schenkelhalsbruch ein mechanisches problem. Z Orthop Ihre Grensgeb. 1935;63:1\u2013135.","journal-title":"Z Orthop Ihre Grensgeb"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200711101-00001"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.86B7.15047"},{"key":"e_1_3_1_14_2","first-page":"131","article-title":"Soft-tissue balancing of the hip: the role of femoral offset restoration","volume":"54","author":"Charles MN","year":"2005","unstructured":"Charles MN, Bourne RB, Davey JR, Greenwald AS, Morrey BF, Rorabeck CH. Soft-tissue balancing of the hip: the role of femoral offset restoration. Instr Course Lect. 2005;54:131\u2013141.","journal-title":"Instr Course Lect"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.77B6.7593096"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.11.015"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.12.008"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/0020-1383(86)90322-0"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453678709146468"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100050316"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.E.00535"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31814b822e"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199910000-00037"},{"key":"e_1_3_1_24_2","first-page":"256","article-title":"Basicervical fractures of the proximal femur: a biomechanical study of 3 internal fixation techniques","volume":"306","author":"Blair B","year":"1994","unstructured":"Blair B, Koval KJ, Kummer F, Zuckerman JD. Basicervical fractures of the proximal femur: a biomechanical study of 3 internal fixation techniques. Clin Orthop Relat Res. 1994;306:256\u2013263.","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199707000-00007"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3181bba236"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mehy.2015.01.029"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.12.031"},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(17)30066-1"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/01477447-20190321-03","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T21:23:25Z","timestamp":1683062605000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20190321-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,7]]}},"alternative-id":["10.3928\/01477447-20190321-03"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20190321-03","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7]]}}}