{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T18:39:51Z","timestamp":1790793591209,"version":"4.1.0"},"reference-count":35,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:p>\n                    The use of 3-dimensional (3D) printing in orthopedics is developing rapidly and impacting the areas of preoperative planning, surgical guides, and simulation. As this technology continues to improve, the greatest impact of 3D printing may be in low- and middle-income countries where surgical items are in short supply. This study investigated sterility of 3D-printed ankle fracture fixation plates and cortical screws. The hypothesis was that the process of heated extrusion in fused deposition modeling printing would create sterile prints in a timely fashion that would not require postproduction sterilization. A free computer-assisted design program was used to design the implant models. One control group and 8 study groups were printed. Print construct, orientation, size, and postproduction sterilization differed among the groups. Sterility was assessed using thioglycollate broth cultures at 24 hours, 48 hours, and 7 days. Positive growth was speciated for aerobic and anaerobic bacteria. Print time and failed prints were recorded. Control samples were 100% positive for bacterial growth. All test samples remained sterile at all time points (100%). Speciation of control samples was obtained, and\n                    <jats:italic>Staphylococcus<\/jats:italic>\n                    was the most common species. Print times varied; however, no print time exceeded 6.75 minutes. Eighteen prints (17%) failed in the printing process. These findings demonstrate an intrinsic sterilization process associated with fused deposition modeling 3D printing and indicate the feasibility of 3D-printed surgical implants and equipment for orthopedic applications. With future research, 3D-printed implants may be a treatment modality to assist orthopedic surgeons in low- and middle-income countries. [\n                    <jats:italic>Orthopedics<\/jats:italic>\n                    . 2020; 43(1): 46\u201351.]\n                  <\/jats:p>","DOI":"10.3928\/01477447-20191031-07","type":"journal-article","created":{"date-parts":[[2019,11,6]],"date-time":"2019-11-06T16:50:05Z","timestamp":1573059005000},"page":"46-51","source":"Crossref","is-referenced-by-count":18,"title":["Sterility of 3D-Printed Orthopedic Implants Using Fused Deposition Modeling"],"prefix":"10.3928","volume":"43","author":[{"given":"Nathan W.","family":"Skelley","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael P.","family":"Hagerty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James T.","family":"Stannard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin P.","family":"Feltz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.5812\/traumamon.16215"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2005.10.016"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2012.672091"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.fas.2016.11.002"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2016-014496"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1596\/1813-9450-6699"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-018-4630-x"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1083-7515(02)00162-6"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00653"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(10)61458-4"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1086\/321860"},{"issue":"6","key":"e_1_3_1_13_2","first-page":"1","article-title":"Surgical site infections in developing countries: current burden and future challenges","volume":"5","author":"Asaad AM","year":"2016","unstructured":"Asaad AM, Badr SA. Surgical site infections in developing countries: current burden and future challenges. Clin Microbiol. 2016;5(6):1\u20132.","journal-title":"Clin Microbiol"},{"issue":"10","key":"e_1_3_1_14_2","first-page":"704","article-title":"Medical applications for 3D printing: current and projected uses","volume":"39","author":"Ventola CL","year":"2014","unstructured":"Ventola CL. Medical applications for 3D printing: current and projected uses. P T. 2014;39(10):704\u2013711. PMID:25336867","journal-title":"P T"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2014.9542"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.17.00544"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.3171\/2016.9.SPINE16371"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20130327-06"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20151016-05"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.94B11.29350"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20180109-04"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1177\/0003489415570937"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-018-2979-4"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/JPO.0000000000000097"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.CC.17.00212"},{"key":"e_1_3_1_26_2","volume-title":"Steam Sterilization Disinfection and Sterilization Guidelines","author":"Rutala WA","year":"2018","unstructured":"Rutala WA, Weber DJ. Steam Sterilization Disinfection and Sterilization Guidelines. Atlanta, GA: Centers for Disease Control and Prevention; 2018."},{"issue":"5","key":"e_1_3_1_27_2","first-page":"13","article-title":"Types of plastics","volume":"50","author":"Griffey J","year":"2014","unstructured":"Griffey J. Types of plastics. Libr Technol Rep. 2014;50(5):13\u201315.","journal-title":"Libr Technol Rep"},{"key":"e_1_3_1_28_2","first-page":"68","volume-title":"Use of International Standard ISO 10993\u20131, Biological Evaluation of Medical Devices: Part 1. Evaluation and Testing Within a Risk Management Process","author":"Center for Devices and Radiological Health","year":"2016","unstructured":"Center for Devices and Radiological Health. Use of International Standard ISO 10993\u20131, Biological Evaluation of Medical Devices: Part 1. Evaluation and Testing Within a Risk Management Process. Rockville, MD: Center for Devices and Radiological Health; 2016:68."},{"key":"e_1_3_1_29_2","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.2661"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1590\/S0104-66322007000200010"},{"key":"e_1_3_1_31_2","volume-title":"Sterilization of FDM-Manufactured Parts","author":"Perez M","year":"2012","unstructured":"Perez M, Block M, Espalin D, et al. Sterilization of FDM-Manufactured Parts. El Paso, TX: The University of Texas at El Paso; 2012."},{"key":"e_1_3_1_32_2","doi-asserted-by":"publisher","DOI":"10.1177\/0095244312457797"},{"key":"e_1_3_1_33_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1099-1522(199905\/06)12:3<119::AID-PTS460>3.0.CO;2-G"},{"key":"e_1_3_1_34_2","volume-title":"Chemical Resistance Guide: Acrylonitrile Butadiene Styrene (ABS) for Pressure Applications.","author":"IPEX","year":"2018","unstructured":"IPEX. Chemical Resistance Guide: Acrylonitrile Butadiene Styrene (ABS) for Pressure Applications. 2nd ed. Montreal, Quebec, Canada: IPEX; 2018.","edition":"2"},{"key":"e_1_3_1_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(15)60160-X"},{"key":"e_1_3_1_36_2","volume-title":"LulzBot Mini User Manual","author":"Aleph Objects Inc","year":"2016","unstructured":"Aleph Objects Inc. LulzBot Mini User Manual. Indianapolis, IN: Aleph Objects Inc; 2016."}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/01477447-20191031-07","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T02:25:45Z","timestamp":1683080745000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20191031-07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1]]}},"alternative-id":["10.3928\/01477447-20191031-07"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20191031-07","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}