{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,5,4]],"date-time":"2023-05-04T04:18:13Z","timestamp":1683173893893},"reference-count":42,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:p>\n            Bicortical drilling of the clavicle is associated with risk of iatrogenic damage from plunging given the close proximity of neurovascular structures. This study determined plunge depth during superior-to-inferior clavicle drilling using a standard drill vs drill-sensing technology. Two orthopedic surgeons drilled 10 holes in a fresh cadaveric clavicle with drill-sensing technology in freehand mode (functions as standard orthopedic drill) and another 10 holes with drill-sensing technology in bicortical mode (drill motor stops when the second cortex is breached and depth is measured in real time). The drill-measured depths were compared with computed tomography\u2013measured depths. Distances to the neurovascular structures were also measured. The surgeons' plunge depths were compared using an independent\n            <jats:italic>t<\/jats:italic>\n            test. With freehand (standard) drilling, the mean plunge depth was 8.8 mm. For surgeon 1, the range was 5.6 to 15.8 mm (mean, 10.9 mm). For surgeon 2, the range was 3.3 to 11.0 mm (mean, 6.4 mm). The surgeons' plunge depths were significantly different. In bicortical mode, the drill motor stopped when the second cortex was penetrated. Drill-measured depths were verified by computed tomography scan, with a mean difference of 0.8 mm. Mean distances from the clavicle to the neurovascular structures were 15.5 mm for the subclavian vein, 18.0 mm for the subclavian artery, and 8.0 mm for the brachial plexus. Plunge depths differed between surgeons. However, both surgeons' plunge depths were greater than distances to the neurovascular structures, indicating a risk of injury due to plunging. Although a nonspinning drill bit may still cause soft tissue damage, drill-sensing technology may decrease the risk of penetrating soft tissue structures due to plunging. [\n            <jats:italic>Orthopedics<\/jats:italic>\n            . 2021;44(1):e36\u2013e42.]\n          <\/jats:p>","DOI":"10.3928\/01477447-20201202-07","type":"journal-article","created":{"date-parts":[[2020,12,7]],"date-time":"2020-12-07T19:47:10Z","timestamp":1607370430000},"source":"Crossref","is-referenced-by-count":0,"title":["Plunging Dangerously: A Quantitative Assessment of Drilling the Clavicle"],"prefix":"10.3928","volume":"44","author":[{"given":"Stephanie A.","family":"Russo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James A.","family":"DeLullo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Z","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Radley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel S.","family":"Gloekler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryan M.","family":"Vellinga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zubair","family":"Chaudry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mary K.","family":"Mulcahey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-323-07243-4.00053-0"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-1-4160-2220-6.10004-0"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2001.21539"},{"issue":"1","key":"e_1_3_2_5_2","first-page":"30","article-title":"Vascular risk associated with bicortical tibial drilling during anteromedial tibial tubercle transfer","volume":"35","author":"Kline AJ","year":"2006","unstructured":"Kline AJ, Gonzales J, Beach WR, Miller MD. Vascular risk associated with bicortical tibial drilling during anteromedial tibial tubercle transfer. Am J Orthop (Belle Mead NJ).2006;35(1):30\u201332. PMID:16475421","journal-title":"Am J Orthop (Belle Mead NJ)"},{"issue":"3","key":"e_1_3_2_6_2","first-page":"137","article-title":"Vascular risk associated with a posterior approach for posterior cruciate ligament reconstruction using the tibial inlay technique","volume":"15","author":"Miller MD","year":"2002","unstructured":"Miller MD, Kline AJ, Gonzales J, Beach WR. Vascular risk associated with a posterior approach for posterior cruciate ligament reconstruction using the tibial inlay technique. J Knee Surg. 2002;15(3):137\u2013140. PMID:12152973","journal-title":"J Knee Surg"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-014-3214-z"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2014.03.026"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20091124-09"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3181bbd617"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31828c1e37"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.08.031"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-014-3853-x"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.93B9.25739"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2009.01.021"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.TA.0000085862.32648.05"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20120123-21"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199707000-00035"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/0967-2109(95)00095-X"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/1758573214546058"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.4103\/0973-6042.76969"},{"issue":"6","key":"e_1_3_2_22_2","first-page":"442","article-title":"Drilling sounds are used by surgeons and intermediate residents, but not novice orthopedic trainees, to guide drilling motions","volume":"51","author":"Praamsma M","year":"2008","unstructured":"Praamsma M, Carnahan H, Backstein D, Veillette CJ, Gonzalez D, Dubrowski A. Drilling sounds are used by surgeons and intermediate residents, but not novice orthopedic trainees, to guide drilling motions. Can J Surg. 2008;51(6):442\u2013446. PMID:19057732","journal-title":"Can J Surg"},{"key":"e_1_3_2_23_2","doi-asserted-by":"crossref","first-page":"211","DOI":"10.5005\/jp\/books\/12056_10","volume-title":"Contemporary Surgical Management of Fractures and Complications: Pediatrics","author":"Bloom T","year":"2014","unstructured":"Bloom T, Sabharwal S. Tibial shaft fractures. In , Herman MJ, Horn BD, eds. Contemporary Surgical Management of Fractures and Complications: Pediatrics. vol 3. Jaypee Brothers Medical Publishers; 2014:211\u2013246."},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2016.10.044"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e3182336ec3"},{"key":"e_1_3_2_26_2","doi-asserted-by":"crossref","unstructured":"IntelliSense Drill Technology. McGinley Orthopaedics. Accessed January 13 2020. https:\/\/www.mcginleyorthopaedicinnovations.com\/drill","DOI":"10.1016\/S1350-4789(20)30206-3"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-013-1755-0"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3171\/2013.2.SPINE12879"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1960.03020100014003"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1067\/mse.2002.126613"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199403000-00016"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.M.00607"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.95B1.29625"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.CC.L.00194"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.00307"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.bot.0000172287.44278.ef"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.01999"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00020"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.15.01394"},{"key":"e_1_3_2_40_2","first-page":"490","article-title":"So you think you don't plunge? An assessment of far cortex drill tip plunging based on level of training","volume":"30","author":"Leis A","year":"2017","unstructured":"Leis A, Sharpe F, Hill JR, et al. So you think you don't plunge? An assessment of far cortex drill tip plunging based on level of training. Surg Technol Int. 2017;30:490\u2013495. PMID:28693046","journal-title":"Surg Technol Int"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2015.11.065"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.01336"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.01364"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/01477447-20201202-07","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:11:12Z","timestamp":1683112272000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20201202-07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.3928\/01477447-20201202-07"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20201202-07","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1]]}}}