{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T10:55:22Z","timestamp":1770288922502,"version":"3.49.0"},"reference-count":23,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orthopedics"],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:p>Fixation of humeral shaft fractures is frequently performed with large-fragment (4.5 mm) plates to accommodate immediate weight bearing. Use of small-fragment (3.5 mm) plates as an alternative carries theoretical benefits. We examined nonunion rates and postoperative radial nerve palsy (RNP) rates in a retrospective cohort of patients undergoing open reduction and internal fixation of humeral shaft fractures with 3.5-mm or 4.5-mm plates. Two hundred thirty-six patients with 241 humeral shaft fractures were included. Small 3.5-mm plates were used in 83% of the patients, and large 4.5-mm plates were used in 17% of the patients. Fifty-three percent were made weight bearing as tolerated following surgical fixation. There was a 7% incidence of nonunion and a 10% incidence of RNP in the 3.5-mm plate group. There was a 7% incidence of nonunion and a 15% incidence of RNP in the 4.5-mm plate group. No statistically significant relationship was shown between nonunion or RNP and plate size (<jats:italic>P<\/jats:italic>=.74 and<jats:italic>P<\/jats:italic>=.39). No relationship was shown between nonunion and postoperative weight-bearing status (<jats:italic>P<\/jats:italic>=.45). Subgroup analysis according to plate size additionally showed no association of nonunion with postoperative weight bearing in both the 4.5-mm (<jats:italic>P<\/jats:italic>=.55) and the 3.5-mm (<jats:italic>P<\/jats:italic>=.25) cohorts. Small-fragment and large-fragment plating of humeral shaft fractures resulted in comparable union and RNP rates, regardless of postoperative weight-bearing status. Our findings suggest that 3.5-mm plate fixation of humeral shaft fractures is a safe alternative to 4.5-mm plate fixation. [<jats:italic>Orthopedics<\/jats:italic>. 2023;46(4):198\u2013204.]<\/jats:p>","DOI":"10.3928\/01477447-20230224-02","type":"journal-article","created":{"date-parts":[[2023,2,28]],"date-time":"2023-02-28T18:31:35Z","timestamp":1677609095000},"page":"198-204","source":"Crossref","is-referenced-by-count":3,"title":["Small-Fragment Plate Fixation of Humeral Shaft Fractures"],"prefix":"10.3928","volume":"46","author":[{"given":"Christopher G.","family":"Langhammer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuliana","family":"Rotunno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina","family":"Sebastian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason W.","family":"Nascone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert V.","family":"O'Toole","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W. Andrew","family":"Eglseder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcus F.","family":"Sciadini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","volume-title":"Rockwood and Green's Fractures in Adults","author":"Rockwood CA","year":"2010","unstructured":"Rockwood CA, Green DP, Bucholz RW. Rockwood and Green's Fractures in Adults. 7th ed. Wolters Kluwer Health\/Lippincott Williams & Wilkins; 2010.","edition":"7"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00776-013-0497-8"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610046037"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000000599"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-021-01728-7"},{"key":"e_1_3_1_7_2","first-page":"2021","volume-title":"Skeletal Trauma of the Upper Extremity","author":"Garrigues G","unstructured":"Garrigues G, Richard M, Gage M. Skeletal Trauma of the Upper Extremity. Elsevier; 2021."},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-66857-4"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2020.3182"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamasurg.2021.0906"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-200008000-00014"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-D-20-01252"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.TA.0000169930.79684.4E"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31818df8cb"},{"issue":"4","key":"e_1_3_1_15_2","first-page":"175","article-title":"Biomechanical testing of unstable humeral shaft fracture plating","volume":"18","author":"Catanzarite J","year":"2009","unstructured":"Catanzarite J, Alan R, Baig R, Forno P, Benson L. Biomechanical testing of unstable humeral shaft fracture plating. J Surg Orthop Adv. 2009;18(4):175\u2013181. PMID:19995496","journal-title":"J Surg Orthop Adv"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e3181df968c"},{"key":"e_1_3_1_17_2","doi-asserted-by":"crossref","DOI":"10.60118\/001c.25328","article-title":"Immediate weight bearing after fixation of humeral shaft fractures with small fragment hybrid plating: a biomechanical analysis","author":"Bledsoe JG","year":"2021","unstructured":"Bledsoe JG, Geraud S, Cannada LK. Immediate weight bearing after fixation of humeral shaft fractures with small fragment hybrid plating: a biomechanical analysis. J Orthopaedic Experience & Innovation. 2021.","journal-title":"J Orthopaedic Experience & Innovation"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950x.2004.04025.x"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2008.00433.x"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e318214ebd5"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001062"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/BTH.0000000000000017"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1177\/2309499019839608"},{"issue":"1","key":"e_1_3_1_24_2","first-page":"10","article-title":"Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries","volume":"6","author":"Dabezies EJ","year":"1992","unstructured":"Dabezies EJ, Banta CJII, Murphy CP, D'Ambrosia RD. Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries. J Orthop Trauma. 1992;6(1):10\u201313. PMID:1556609","journal-title":"J Orthop Trauma"}],"container-title":["Orthopedics"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,12,7]],"date-time":"2023-12-07T23:52:01Z","timestamp":1701993121000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01477447-20230224-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,7]]}},"alternative-id":["10.3928\/01477447-20230224-02"],"URL":"https:\/\/doi.org\/10.3928\/01477447-20230224-02","relation":{},"ISSN":["0147-7447","1938-2367"],"issn-type":[{"value":"0147-7447","type":"print"},{"value":"1938-2367","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7]]}}}