{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T21:47:04Z","timestamp":1774993624530,"version":"3.50.1"},"reference-count":17,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[1993,9]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>We measured the intraocular pressure (IOP) of 50 normal, cooperative, awake children below 5 years of age and 12 normal, volunteer adults with the Perkins hand-held applanation tonometer (Perkins) and the Digilab pneumatonographer-tonometer (Pneuma). Neither sedation, general anesthesia, nor lid specula were used. We confirmed others' findings that the normal IOP, measured in the supine position with the Perkins, is lower in infants and young children (x = 5.89 mm Hg) than in adults (x = 13.21 mm Hg; P &lt; .0001). On the other hand, with the Pneuma, the supine pediatric IOP (x = 14.76 mm Hg) was not significantly different from the adult sitting IOP (x = 14.42 mm Hg; P = .497). Regression analysis suggests that children and adult Perkins IOP may become equal at around age 12 years.<\/jats:p>","DOI":"10.3928\/0191-3913-19930901-04","type":"journal-article","created":{"date-parts":[[2021,4,20]],"date-time":"2021-04-20T06:33:14Z","timestamp":1618900394000},"page":"284-287","source":"Crossref","is-referenced-by-count":38,"title":["Normal Intraocular Pressure in Children: A Comparative Study of the Perkins Applanation Tonometer and the Pneumatonometer"],"prefix":"10.3928","volume":"30","author":[{"given":"Mohamad S","family":"Jaafar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ghulamqadir A","family":"Kazi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","unstructured":"1. Kolker AE Hetherington J Jr. Becker-Shaffer's Diagnosis and Therapy of the Glaucomas. 5th ed. St Louis Mo: The CV Mosby Co; 1983: 317-362."},{"key":"e_1_3_1_3_1","unstructured":"2. Walton DS. Considerations peculiar to infants and children. In: Epstein DL ed. Chandler and Grant's Glaucoma. Philadelphia Pa: Lea & Febiger; 1986:469-479."},{"key":"e_1_3_1_4_1","unstructured":"3. Apt L. Tonography in infantile glaucoma. Am J Ophthalmol. 1957;43:624."},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Dom\u00ednguez A Banos MS Alvarez MG Contra GF Qu\u00edntela FB. Intraocular pressure measurement in infants under general anesthesia. Am J Ophthalmol. 1974;78:110-116.","DOI":"10.1016\/0002-9394(74)90018-X"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Radtke ND Cohan BE. Intraocular pressure measurement in the newborn. Am J Ophthalmol. 1974;78:501-504.","DOI":"10.1016\/0002-9394(74)90239-6"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Quigley HA. Childhood glaucoma: results with trabeculotomy and study of reversible cupping. Ophthalmology. 1982;89:219-226.","DOI":"10.1016\/S0161-6420(82)34803-4"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. deLuise VP Anderson DR. Primary infantile glaucoma (congenital glaucoma). Surv Ophthalmol. 1983;28:1-19.","DOI":"10.1016\/0039-6257(83)90174-1"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Goethals M Missotten L. Intraocular pressure in children up to five years of age. J Pediatr Ophthalmol Strabismus. 1983;20:49-51.","DOI":"10.3928\/0191-3913-19830301-03"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Kao SF Lichter PR Bergstrom TJ Rowe S Musch DC. Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer. Ophthalmology. 1987;94:1541-1544.","DOI":"10.1016\/S0161-6420(87)33249-X"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Frenkel RE Hong VYJ Shin DH. Comparison of the Tono-Pen to the Goldmann applanation tonometer. Arch Ophthalmol. 1988; 106:750-753.","DOI":"10.1001\/archopht.1988.01060130820030"},{"key":"e_1_3_1_12_1","unstructured":"11. Kooner KS Cooksey JC Barron JB Zimmerman IV Gupte RK Wall JL. Tonometry comparison: Goldmann versus Tono-pen. Ann Ophthalmol. 1992;24:29-36."},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Pensiero S Da Pozzo S Perissutti P Cavallini GM Guerra R. Normal intraocular pressure in children. J Pediatr Ophthalmol Strabismus. 1992; 29:79-84.","DOI":"10.3928\/0191-3913-19920301-05"},{"key":"e_1_3_1_14_1","unstructured":"13. Hetherington J Jr Shaffer RN. Tonometry and tonography congenital glaucoma. Invest Ophthalmol. 1968;7:134-137."},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. de Luca Dear G Hammerton M Hatch DJ Taylor D. Anaesthesia and intraocular pressure in young children. A study of three different techniques of anesthesia. Anaesthesia. 1987;42:259-265.","DOI":"10.1111\/j.1365-2044.1987.tb03036.x"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Bradinath SK Vazeery A McCarthy RJ Ivankovich AD. The effect of different methods of inducing anesthesia on intraocular pressure. Anesthesiology. 1986;65:431-435.","DOI":"10.1097\/00000542-198610000-00016"},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Watcha MF Chu FC Stevens JL Forestner JE. Effects of Halothane on intraocular pressure in anesthetized children. Anesth Analg. 1990;71:181- 184.","DOI":"10.1213\/00000539-199008000-00011"},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Quigley HA Langham ME. Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer. Am J Ophthalmol. 1975;80:266-273.","DOI":"10.1016\/0002-9394(75)90144-0"}],"container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T19:30:35Z","timestamp":1683055835000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0191-3913-19930901-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1993,9]]},"references-count":17,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1993,9]]}},"alternative-id":["10.3928\/0191-3913-19930901-04"],"URL":"https:\/\/doi.org\/10.3928\/0191-3913-19930901-04","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[1993,9]]}}}