{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T19:44:52Z","timestamp":1795031092091,"version":"4.10.2"},"reference-count":26,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[1995,11]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>Measuring the intraocular pressure (IOP) in children can be difficult. We compared the accuracy of IOP measurements in pediatrie patients using three tonometers: Perkins, Schi\u00f6tz, and Tono-pen. Seventy-seven children (132 eyes; average age, 1 year, 7 months; range, 1 month to 60 months), mainly afflicted with retinopathy of prematurity (107 eyes), were evaluated. A good correlation (r=0.867) was found between the Tono-pen and the Perkins tonometers. No statistical difference was found between the mean difference of IOP values obtained with the Tonopen and the Perkins (P&gt;.05). The Schi\u00f6tz measurements were significantly higher than those obtained with the Perkins and the Tono-pen tonometers (P&lt;.05).We concluded that the Tono-pen tonometer has a higher correlation coefficient, comparable to the Perkins tonometer, and can be used reliably to assess IOP in pediatrie patients.<\/jats:p>","DOI":"10.3928\/0191-3913-19951101-10","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T01:37:23Z","timestamp":1619055443000},"page":"373-377","source":"Crossref","is-referenced-by-count":34,"title":["Tonometry in Pediatric Patients: A Comparative Study Among Tono-pen, Perkins, and Schi\u00f6tz Tonometers"],"prefix":"10.3928","volume":"32","author":[{"given":"Arnaldo F","family":"Bordon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamu","family":"Katsumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuo","family":"Hirose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. MacKay RS Marg E. Fast automatic electronic tonometers based on an exact theory. Acto Ophthalmol. 1959;37:495-507.","DOI":"10.1111\/j.1755-3768.1959.tb03461.x"},{"key":"e_1_3_1_3_1","unstructured":"2. Ray WA OT)ay DM. Statistical analysis of multi-eye data in ophthalmic research. Invest Ophthalmol Vis Sd. 1985;26:1186-1188."},{"key":"e_1_3_1_4_1","unstructured":"3. Brubaker RF. Tonometry. In Tasman W Jaeger EA eds. Duane's Clinical Ophthalmology vol 3. Philadelphia Pa: JB Lippincott; 1992:1-7."},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Perkins ES. Hand-held applanation tonometer. Br J Ophthalmol. 1965;49:591-593.","DOI":"10.1136\/bjo.49.11.591"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Stein RA Whitacre MM. Modification of the Perkins tonometer. Am J Ophthalmol. 1994;117:269-270.","DOI":"10.1016\/S0002-9394(14)73094-6"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Whitacre MM Stein PA. Sources of error with the use of Goldmann-type tonometers. Sum Ophthalmol. 1993;38:1-30.","DOI":"10.1016\/0039-6257(93)90053-A"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Minckler DS Baerveldt G Heuer DK Quillen-Thomas B Walonker AF Weiner J. Clinical evaluation of the oculab Tono-pen. Am J Ophthalmol. 1987; 104: 168-1 73.","DOI":"10.1016\/0002-9394(87)90010-9"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Nendelshon AD Forster RK Mendelsohn SL et al. Comparative tonometric measurements of eye bank eyes. Cornea. 1987;6:219-225.","DOI":"10.1097\/00003226-198706030-00014"},{"key":"e_1_3_1_10_1","unstructured":"9. Craven ER Katz LJ Steinmann WC Samuel F Spaeth GL. Comparison of hand-held digital tonometer with Goldmann applanation tonometry in patients with various ocular diseases. Invest Ophthalmol Vis Sci. 1988;29(suppl):61. Abstract."},{"key":"e_1_3_1_11_1","unstructured":"10. Stamper RL Gardner ID Bron AJ. Evaluation of a new portable tonometer with digital display. Ophthalmology. 1987 ;94(suppl): 133."},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Hines MW Jost BF Fogelman KL. Oculab Tono-pen Goldmann applanation tonometry and pneumatic tonometry for intraocular pressure assessment in gas-filled eyes. Am J Opkthalmol. 1988; 106: 174-179.","DOI":"10.1016\/0002-9394(88)90830-6"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Soothe WA Lee DA Panek WC Petit TH. The Tono-pen: a manometric and clinical study. Arch Ophthalmol. 1988; 106: 12 14- 12 17.","DOI":"10.1001\/archopht.1988.01060140374035"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Hessemer V Rossler R Jacobi KW. Comparison of intraocular pressure measurements with the Oculab Tono-pen vs manometry in humans shortly after death. Am J Ophthalmol. 1988; 105: 6 78-682.","DOI":"10.1016\/0002-9394(88)90064-5"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Panek WC Boothe WA Lee DA Zemplenyi E Pettit TH. Intraocular pressure measurements with the Tono-pen through soft contact lenses. Am J Ophthalmol. 1990; 109: 62 -65.","DOI":"10.1016\/S0002-9394(14)75580-1"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Rootman DS Insler MS Thompson HW Parelman J Poland D Untennan SR. Accuracy and precision of the Tono-pen in measuring intraocular pressure after keratoplasty and epikeratophakia and in scarred corneas. Arch Ophthalmol. 1988; 106: 169 7- 1700.","DOI":"10.1001\/archopht.1988.01060140869030"},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Khan JA LaGreca BA. Tono-pen estimation of intraocular pressure through bandage contact lenses. Am J Ophthalmol. 1989; 108: 422-425.","DOI":"10.1016\/S0002-9394(14)73310-0"},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Frenkel REP Hong YJ Shin DH. Comparison of the Tono-pen to the Goldroann applanation tonometer. Arch Ophthalmol. 1988; 106: 750-7 53.","DOI":"10.1001\/archopht.1988.01060130820030"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Geyer O Mayron Y Loewenstein A Neudorfer M Rothkoff L Lazar M. Tono-pen tonometry in normal and in post-keratoplasty eyes. Br J Ophthalmol. 1992; 76: 538-540.","DOI":"10.1136\/bjo.76.9.538"},{"key":"e_1_3_1_20_1","unstructured":"19. Kao SF Lichter PR Bergstrom TJ Rowe S Musch DC. Clinical comparison of the Oculab Tono-pen to the Goldmann applanation tonometer. Ophthalmology. 1 987 ;94: 154 1-1 544."},{"key":"e_1_3_1_21_1","doi-asserted-by":"crossref","unstructured":"20. Parrar SM Miller KN Shields MB Stoup CM. An evaluation of the Tono-pen for the measurement of diurnal intraocular pressure. Am J Ophthalmol. 1989;107:411-416.","DOI":"10.1016\/0002-9394(89)90666-1"},{"key":"e_1_3_1_22_1","doi-asserted-by":"crossref","unstructured":"21. Parrar SM Miller KN Shields MB Stoup CM. Tono-pen a new tonometer. International Ophthalmology. 1989; 13: 51-56.","DOI":"10.1007\/BF02028638"},{"key":"e_1_3_1_23_1","unstructured":"22. Kooner KS Cooksey JC Barron JB Zimmerman TJ Gupte RK Wall JL. Tonometry comparison: Goldmann versus Tono-pen. Ann Ophthalmol. 1992:24:29-36."},{"key":"e_1_3_1_24_1","doi-asserted-by":"crossref","unstructured":"23. Whitacre MM Emig M Haseanein K. The effect of Perkins Tono-pen and Schi\u00f6tz tonometry on intraocular pressure. Am J Ophthalmol. 1991;lll:59-64.","DOI":"10.1016\/S0002-9394(14)76898-9"},{"key":"e_1_3_1_25_1","doi-asserted-by":"crossref","unstructured":"24. Holec-Iwasko S Shin DH Parrow KA Wilkinson MJ Dunn SH. The influence of residual methylcellulose solution on Tono-pen readings. Am J Ophthalmol. 1990; 109:602-603.","DOI":"10.1016\/S0002-9394(14)70697-X"},{"key":"e_1_3_1_26_1","doi-asserted-by":"crossref","unstructured":"25. Hartnett ME Gilbert MM Richardson TM Krug JH Jr Hirose T. Anterior segment evaluation of infants with retinopathy of prematurity. Ophthalmology. 1990;97:122-130.","DOI":"10.1016\/S0161-6420(90)32637-4"},{"key":"e_1_3_1_27_1","doi-asserted-by":"crossref","unstructured":"26. Hartoett ME Hirose T Richardson TM Garsd A Gilbert MM Krug JH Jr. Intraocular pressure determination in infants with severe retinopathy of prematurity. Graefe's Arch Clin Exp Ophthalmol. 1992;230:406-410.","DOI":"10.1007\/BF00175923"}],"container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T08:32:52Z","timestamp":1683102772000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0191-3913-19951101-10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,11]]},"references-count":26,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1995,11]]}},"alternative-id":["10.3928\/0191-3913-19951101-10"],"URL":"https:\/\/doi.org\/10.3928\/0191-3913-19951101-10","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,11]]}}}