{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T15:59:58Z","timestamp":1773763198671,"version":"3.50.1"},"reference-count":18,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[1996,7]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>Background: Although manual capsulorhexis is an ideal anterior capsulectomy technique for adults, it is more difficult to perform in very young eyes because the capsular bag is more elastic. Our mechanized anterior capsulectomy technique has compared favorably with manual capsulorhexis in the laboratory using autopsy eyes. We now report the results of circular mechanized anterior capsulectomy in consecutive pediatric patients receiving a posterior chamber intraocular lens (IOL) after cataract extraction.<\/jats:p>\n          <jats:p>Methods: Twenty eyes of 17 consecutive patients between 6 months and 13 years of age underwent a mechanized anterior capsulectomy followed by IOL implantation into the capsular bag. The integrity of the anterior capsular edge was evaluated at the completion of capsulectomy, prior to IOL insertion, and at the end of surgery.<\/jats:p>\n          <jats:p>Results: A single radial tear developed in three eyes (15%) of two patients (12%). In the remaining 17 eyes (85%), an intact circular capsulectomy edge was verified at the completion of the mechanized capsulectomy, at the end of IOL insertion, and at the completion of surgery. Complete in-the-bag capsular fixation of the IOL was accomplished in all 20 eyes. Both patients who sustained radial tears were older children (age 11 years). All IOLs remain well centered behind a smooth circular anterior capsular edge after a minimum follow up of 6 months.<\/jats:p>\n          <jats:p>Conclusion: A mechanized anterior capsulectomy technique can produce a circular capsular opening that resists tearing during lens aspiration and IOL insertion. The vitrector-cut capsulectomy performed well even in the youngest patients in whom manual capsulorhexis would have been difficult to control.<\/jats:p>","DOI":"10.3928\/0191-3913-19960701-07","type":"journal-article","created":{"date-parts":[[2021,4,20]],"date-time":"2021-04-20T20:42:34Z","timestamp":1618951354000},"page":"237-240","source":"Crossref","is-referenced-by-count":41,"title":["Mechanized Anterior Capsulectomy as an Alternative to Manual Capsulorhexis in Children Undergoing Intraocular Lens Implantation"],"prefix":"10.3928","volume":"33","author":[{"given":"M Edward","family":"Wilson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard A","family":"Saunders","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric L","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David J","family":"Apple","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Assia EI Apple DJ Barden A et al. An experimental study comparing various anterior capsulectomy techniques. ArcA Ophthalmol. 1991;109:642-647.","DOI":"10.1001\/archopht.1991.01080050056028"},{"key":"e_1_3_1_3_1","unstructured":"2. Apple DJ Assia El Wasserman D et al. Evidence in support of the continuous tear anterior capsulectomy (capsulorhexis technique). In: Cangelosi GC ed. Advances in Cataract Surgery. Thorofare NJ: Slack Ine; 1991:21-27."},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Gimbel HV Neuhann T. Development advantages and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990;16:31-37.","DOI":"10.1016\/S0886-3350(13)80870-X"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Gimbel HV Ferensowicz M Rasnan M DeLuca M. Implantation in children. J Pediatr Ophthalmol Strabismus. 1993;30:69-79.","DOI":"10.3928\/0191-3913-19930301-03"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Wilson ME Blueetein EC Wang XH et al. Comparison of mechanized anterior capsulectomy and manual continuous capsulorhexis in pediatric eyes. J Cataract Refract Surg. 1994;20:602-606.","DOI":"10.1016\/S0886-3350(13)80646-3"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Wilson ME. Optimal capsulorhexis technique in pediatric eyes. Letter to the editor reply. J Cataract Refract Surg. 1996;22:3-4.","DOI":"10.1016\/S0886-3350(96)80258-6"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Wassennan D Apple DJ Castaneda VE et al. Anterior capsular tears and loop fixation of posterior chamber intraocular lenses. Ophthalmology. 1991;98:425-431.","DOI":"10.1016\/S0161-6420(91)32274-7"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Assia EI Legier UFC Merrill C et al. Clinicopathologic study of the effect of radial tears and loop fixation on intraocular lens decentration. Ophthalmology. 1993;100:153-158.","DOI":"10.1016\/S0161-6420(93)31677-5"},{"key":"e_1_3_1_10_1","unstructured":"9. Apple DJ Auffarth GU Wesendahl TA Pathophysiology of modern capsular surgery (chapter 26). In: Steinert R Fine H Gimbel H et al eds. Cataract Surgery. Philadelphia Pa: WB Saunders; 1995:314-324."},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Assia El Apple DJ Tsai JC et al. The elastic properties of the lens capsule in capsulorhexis. Am J Ophthalmol. 1991;111:628-632.","DOI":"10.1016\/S0002-9394(14)73710-9"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Assia EI Apple DJ Tsai JC et al. Mechanism of radial tear formation and extension after anterior capsulectomy. Ophthalmology. 1991;98:432-437.","DOI":"10.1016\/S0161-6420(91)32273-5"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Davison JA. Analysis of capsular bag defects and intraocular lens positions for consistent centration. J Cataract Refract Surg. 1986;12:124129.","DOI":"10.1016\/S0886-3350(86)80026-8"},{"key":"e_1_3_1_14_1","unstructured":"13. Assia EI Castaneda VE Legier UFC et al. Studies on cataract surgery and intraocular lenses at the Center for Intraocular Lens Research Ophthalmology Clinics of North America. 1991; 4:251-266."},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. McDonnell PJ Champion R Green WR. Location and composition of haptics of posterior chamber intraocular lenses: histopathologic study of postmortem eyes. Ophthalmology. 1987;94:136-142.","DOI":"10.1016\/S0161-6420(87)33485-2"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Hansen SO Tek MR Solomon KD et al. Decentration of flexible loop posterior-chamber intraocular lenses in a series of 222 postmortem eyes. Ophthalmology. 1988;95:344-349.","DOI":"10.1016\/S0161-6420(88)33178-7"},{"key":"e_1_3_1_17_1","unstructured":"16. Apple DJ Kincaid MC Mamalis N Olson RJ. Intraocular Lenses; Evolution Designs Complications and Pathology. Baltimore Md: Williams & Wilkins; 1989."},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Wilson ME Bluestein EC Wang XH. Current trends in the use of intraocular lenses in children. J Cataract Refract Surg. 1994;20:579-583.","DOI":"10.1016\/S0886-3350(13)80642-6"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Krag S Thim K Corydon L Kyster B. Biomechanical aspects of the anterior capsule. J Cataract Refract Surg. 1994;20:410-416.","DOI":"10.1016\/S0886-3350(13)80176-9"}],"container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T22:44:06Z","timestamp":1683067446000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0191-3913-19960701-07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,7]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1996,7]]}},"alternative-id":["10.3928\/0191-3913-19960701-07"],"URL":"https:\/\/doi.org\/10.3928\/0191-3913-19960701-07","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,7]]}}}