{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T10:39:10Z","timestamp":1782729550269,"version":"3.54.5"},"reference-count":8,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[2004,7]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>Purpose: Calculating the power of a secondary intraocular lens (IOL) requires axial lengths and keratometry measurements. In children, these measurements often need to be done under either sedation at the time of surgery or additional sedation. We devised a method of calculating IOL power using only the aphakic refraction and a standard keratometry value.<\/jats:p>\n          <jats:p>Patients and Methods: This retrospective study included children undergoing a secondary IOL procedure who had IOL calculations based on either a measured axial length and a measured keratometry value (with sedation if needed) or a calculated axial length and a standard keratometry value. Comparison of predicted postoperative refraction with actual postoperative refraction was used to evaluate each method.<\/jats:p>\n          <jats:p>Results: The mean difference between predicted and actual postoperative refractions was 2.34 D for the group with actual measurements and 2.50 D for the group with the calculated value method.<\/jats:p>\n          <jats:p>Conclusion: The use of the aphakic refraction to calculate axial length and a standard keratometry value provides an alternative for secondary IOL calculations in pediatric patients when ultrasonic or nonsedated ultrasonic axial length measurements are not an option.<\/jats:p>\n          <jats:p>J Pediatr Ophthalmol Strabismus 2004;41:209-211.<\/jats:p>","DOI":"10.3928\/0191-3913-20040701-07","type":"journal-article","created":{"date-parts":[[2019,1,25]],"date-time":"2019-01-25T22:07:26Z","timestamp":1548454046000},"page":"209-211","source":"Crossref","is-referenced-by-count":10,"title":["Use of the Aphakic Refraction in Intraocular Lens (IOL) Power Calculations for Secondary IOLs in Pediatric Patients"],"prefix":"10.3928","volume":"41","author":[{"given":"Timothy","family":"Hug","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. DeVaro JM Buckley EG Awner S Seaber J. Secondary posterior chamber intraocular lens implantation in pediatric patients. Am J Ophthalmol 1997;123:23-30.","DOI":"10.1016\/S0002-9394(14)70988-2"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Biglan AW Cheng KP Davis JS Gerontis CC. Secondary intraocular lens implantation after cataract surgery in children. Am J Ophthalmol 1997;123:224-234.","DOI":"10.1016\/S0002-9394(14)71040-2"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Awner S Buckley EG DeVaro JM Seaber JH. Unilateral pseudophakia in children under 4 years. J Pediatr Ophthalmol Strabismus 1996;33:230-236.","DOI":"10.3928\/0191-3913-19960701-06"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Awad AH Mullaney PB ??-Hamad A Wheeler D Al-Mesfer S Zwaan J. Secondary posterior chamber intraocular lens implantation in children. JAAPOS 1998;2:269-274.","DOI":"10.1016\/S1091-8531(98)90082-9"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Zwaan J Mullaney PB Awad A Al-Mesfer S Wheeler DT. Pediatric intraocular lens implantation: surgical results and complications in more than 300 patients. Ophthalmology 1998;105:112-118.","DOI":"10.1016\/S0161-6420(98)91568-8"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Tromans C Haigh PM Biswas S Lloyd IC. Accuracy of intraocular lens power calculation in pediatric patients. BrJ Ophthalmol 2001;85:939-941.","DOI":"10.1136\/bjo.85.8.939"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Young TL Bloom JN Ruttum M Sprunger DT Weinstein JM. The IOLAB Inc. pediatric intraocular lens study. J AAPOS 1999;3:295-302.","DOI":"10.1016\/S1091-8531(99)70026-1"},{"key":"e_1_3_1_9_1","unstructured":"8. Hussain M Durrani J. Comparison of intraocular lens power calculation using the Binkhorst and SRK formulae: a clinical study. J Pak Med Assoc 1995;45:38-40."}],"container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T05:48:13Z","timestamp":1683092893000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/0191-3913-20040701-07"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,7]]},"references-count":8,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2004,7]]}},"alternative-id":["10.3928\/0191-3913-20040701-07"],"URL":"https:\/\/doi.org\/10.3928\/0191-3913-20040701-07","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,7]]}}}