{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T13:05:58Z","timestamp":1758632758968},"reference-count":0,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[2006,1]]},"abstract":"<jats:p>&lt;H4&gt;PURPOSE&lt;\/H4&gt; &lt;p&gt;To compare 20-MHz ultrasonography with ophthalmoscopy in the staging of retinopathy of prematurity (ROP).&lt;\/p&gt;&lt;H4&gt;METHODS&lt;\/H4&gt; &lt;p&gt;We used a handheld 20-MHz ultrasound system to examine 38 eyes of 19 neonates who had an indirect ophthalmoscopic examination (diagnosis masked) within 48 hours prior to ultrasonography. Determination of ROP by indirect ophthalmoscopy was compared with independent identification of ultrasonic features indicative of ROP stages.&lt;\/p&gt;&lt;H4&gt;RESULTS&lt;\/H4&gt; &lt;p&gt;In masked cases, ultrasonography correctly identified 13 of 18 (72.2% sensitivity) eyes with zone 2, stage 2 ROP or worse and 19 of 20 (95.0% specificity) normal eyes (zone 2, stage 1 ROP or better) (chi-square, 18.4; &lt;I&gt;P&lt;\/I&gt; &lt; .001).&lt;\/p&gt;&lt;H4&gt;CONCLUSION&lt;\/H4&gt; &lt;p&gt;In the neonatal nursery, a 20-MHz handheld ultrasound system may be an effective screening tool to initially identify ROP for further ophthalmoscopic evaluation and management.&lt;\/p&gt;&lt;p&gt;&lt;CITE&gt;J Pediatr Ophthalmol Strabismus&lt;\/CITE&gt; 2006;43:31-35.&lt;\/p&gt;&lt;H4&gt;AUTHORS&lt;\/H4&gt; &lt;p&gt;Drs. Jokl, Kane, Chiang, Lopez, and Lee are from the Department of Ophthalmology and Dr. Nemerofsky is from the Department of Pediatrics, Columbia University, College of Physicians and Surgeons, New York, New York. Dr. Silverman is from the Department of Ophthalmology, Weill Medical College of Cornell University, New York, New York. Dr. Jokl is also from the Department of Ophthalmology, New York Medical College, New York, New York.&lt;\/p&gt; &lt;p&gt;Originally submitted January 25, 2005.&lt;\/p&gt; &lt;p&gt;Accepted for publication June 20, 2005.&lt;\/p&gt; &lt;p&gt;Address reprint requests to Danny H.-Kauffmann Jokl, MD, 1 Stone Place, Bronxville, NY 10708.&lt;\/p&gt; &lt;p&gt;Supported in part by the National Institutes of Health (grant EB00238), Research to Prevent Blindness, and Quantel Medical, Inc.&lt;\/p&gt; &lt;p&gt;The authors thank John Flynn, MD, for his helpful suggestions.&lt;\/p&gt;<\/jats:p>","DOI":"10.3928\/01913913-20060101-04","type":"journal-article","created":{"date-parts":[[2020,1,7]],"date-time":"2020-01-07T17:58:50Z","timestamp":1578419930000},"page":"31-35","source":"Crossref","is-referenced-by-count":8,"title":["Is There a Role for High-Frequency Ultrasonography in Clinical Staging of Retinopathy of Prematurity?"],"prefix":"10.3928","volume":"43","member":"2308","container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/ophthalmology\/journals\/jpos\/2006-1-43-1\/%7B0600f9a7-81c1-4468-9fbb-f234b09192b8%7D\/is-there-a-role-for-high-frequency-ultrasonography-in-clinical-staging-of-retinopathy-of-prematurity","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T21:58:18Z","timestamp":1683064698000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01913913-20060101-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1]]},"references-count":0,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,1]]}},"alternative-id":["10.3928\/01913913-20060101-04"],"URL":"https:\/\/doi.org\/10.3928\/01913913-20060101-04","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,1]]}}}