{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T03:50:42Z","timestamp":1781754642022,"version":"3.54.5"},"reference-count":19,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[2010,1]]},"abstract":"<jats:sec>\n            <jats:title>EDUCATIONAL OBJECTIVES<\/jats:title>\n            <jats:list list-type=\"order\">\n              <jats:list-item>\n                <jats:label>1.<\/jats:label>\n                <jats:p>To explore whether there is any explanation for children with amblyopia who fail to achieve normal visual acuity.<\/jats:p>\n              <\/jats:list-item>\n              <jats:list-item>\n                <jats:label>2.<\/jats:label>\n                <jats:p>To discuss the optical coherence tomography application in observing the macular abnormality in children with amblyopia.<\/jats:p>\n              <\/jats:list-item>\n              <jats:list-item>\n                <jats:label>3.<\/jats:label>\n                <jats:p>To diagnose and evaluate the potential curable effect on treatment of amblyopia using optical coherence tomography examination.<\/jats:p>\n              <\/jats:list-item>\n            <\/jats:list>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To investigate why some children with amblyopia fail to achieve normal visual acuity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Optical coherence tomography (OCT) was performed to observe the morphology of the macular tissue of children with various types of amblyopia who failed to achieve normal visual acuity (\u2a7d 20\/25). Average thickness of the retinal nerve fiber layer (RNFL) of the foveola and fovea (1-mm diameter range) was then assessed by macular retinal tomography map measurement. The data obtained were compared with those considered normal to detect any abnormality.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Fifteen patients (24 eyes) were examined. Images showed abnormality with thickened RNFL in the macular area in which either the fovea was not observed or the wave lines were flattened or unformed. The average RNFL thickness measured 201.5 \u00b1 17.9 \u00b5m for the foveola and 226.9 \u00b1 11.4 \u00b5m for the fovea (1-mm diameter range). The differences were highly statistically significant compared with normal values. Five cases were ametropic amblyopia, 5 were anisometropic amblyopia, and 5 were idiopathic amblyopia. Eleven cases showed improvement and 4 cases showed no response to the treatment. Twelve cases were myopic, 1 was mixed astigmatism, and 2 were normal. Nine cases were binocular amblyopia and 6 cases were uniocular amblyopia.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Some children with various types of amblyopia who failed to achieve normal visual acuity after treatment showed macular abnormality on OCT examination.<\/jats:p>\n            <jats:p>\n              <jats:bold>[J Pediatr Ophthalmol Strabismus 2010;47:17\u201323.]<\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/01913913-20091019-06","type":"journal-article","created":{"date-parts":[[2009,10,29]],"date-time":"2009-10-29T17:43:57Z","timestamp":1256838237000},"page":"17-23","source":"Crossref","is-referenced-by-count":17,"title":["Macular Abnormality Observed by Optical Coherence Tomography in Children With Amblyopia Failing to Achieve Normal Visual Acuity After Long-Term Treatment"],"prefix":"10.3928","volume":"47","author":[{"given":"Hong","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu","family":"Zhong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qing-Zi","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","first-page":"67","volume-title":"Pediatric Ophthalmology and Strabismus","author":"The Eye MD Association","year":"2006","unstructured":"The Eye MD Association. Pediatric Ophthalmology and Strabismus. San Francisco: American Academy of Ophthalmology; 2006:67\u201375."},{"key":"e_1_3_1_3_2","first-page":"216","volume-title":"Binocular Vision and Ocular Motility","author":"Von Noorden GK","year":"1996","unstructured":"Von Noorden GK. Binocular Vision and Ocular Motility.St. Louis, MO: Mosby; 1996:216\u2013254."},{"key":"e_1_3_1_4_2","first-page":"162","volume-title":"Pediatric Ophthalmology and Strabismus","author":"Kenneth W","year":"2003","unstructured":"Kenneth W, Peter W, Spiegel H. Pediatric Ophthalmology and Strabismus.New York: Springer-Verlag; 2003:162."},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2002.00034.x"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1067\/mpa.2001.117097"},{"key":"e_1_3_1_7_2","first-page":"66","volume-title":"Clinical Application of Optical Coherence Tomography in Ophthalmology","author":"Liu X","year":"2006","unstructured":"Liu X. Clinical Application of Optical Coherence Tomography in Ophthalmology. GuangDong, China: Technology Publishing Company; 2006:66."},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1994.157"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.123.2.149"},{"key":"e_1_3_1_10_2","first-page":"490","article-title":"Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system","volume":"43","author":"Muscat S","year":"2002","unstructured":"Muscat S, Parks S, Kemp E, Keating D. Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system. Invest Ophthalmol Vis Sci. 2002;43:490\u2013495.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.119.8.1135"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006982-200102000-00010"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.85.6.673"},{"key":"e_1_3_1_14_2","first-page":"87","article-title":"Quantitative measurement of macular thickness in normal subjects by optical coherence tomography [article in Chinese]","volume":"16","author":"Ling Y","year":"2000","unstructured":"Ling Y, Liu X, Zheng X. Quantitative measurement of macular thickness in normal subjects by optical coherence tomography [article in Chinese]. Yan Ke Xue Bao. 2000;16:87\u201390.","journal-title":"Yan Ke Xue Bao"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1994.01090240090031"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-0297"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/01913913-20050701-03"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2006.20.3.177"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2005.19.1.62"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1076\/stra.11.1.1.14091"}],"container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/01913913-20091019-06","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,31]],"date-time":"2023-05-31T20:21:10Z","timestamp":1685564470000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01913913-20091019-06"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["10.3928\/01913913-20091019-06"],"URL":"https:\/\/doi.org\/10.3928\/01913913-20091019-06","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1]]}}}