{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T20:45:29Z","timestamp":1782765929384,"version":"3.54.5"},"reference-count":37,"publisher":"SLACK, Inc.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[2023,3,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess the accuracy of intraocular lens (IOL) calculation formulas in pediatric patients with multifocal IOL implantation with optic capture in Berger space.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This prospective observational study enrolled 68 children (101 eyes), aged 3 to 14 years, who received multifocal IOL (Tecnis ZMB00; Abbott Medical Optics) implantation with optic capture in Berger space from June 2019 to June 2020 in Qingdao Eye Hospital. Ocular biometry was performed using the IOLMaster 700 (Carl Zeiss Meditec). The IOL power and intended postoperative refraction were calculated using the Hoffer Q, Barrett Universal II, Holladay, Holladay2, SRK\/T, Haigis, and SRKII formulas. The refractive state of patients, prediction error, and absolute prediction error were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The mean absolute error of the formulas was significantly different (0.49 diopters [D], Hoffer Q; 0.52 D, Barrett Universal II; 0.47 D, Holladay; 0.54 D, Holladay2; 0.52 D, SRK\/T; 0.67 D, Haigis; 0.99 D, SRKII;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001). However, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK\/T formulas had a similar accuracy in predicting refractive error within \u00b10.50 D (62.4%, 59.4%, 62.4%, 62.4%, and 58.4%). There was a trend toward a greater prediction error in eyes with a shorter axial length (\u2264 22 mm) or a steeper cornea (&gt; 43.50 D), for which the Hoffer Q and Holladay2 formulas were more accurate. When the axial length was greater than 22 mm or the corneal curvature was 43.50 D or less, the Holladay, Hoffer Q, and Barrett Universal II formulas were more accurate.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>For patients with pediatric cataract treated with multifocal IOL implantation with optic capture in Berger space, the Hoffer Q, Barrett Universal II, Holladay, Holladay2, and SRK\/T formulas performed better than the other formulas.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic toggle=\"yes\">J Pediatr Ophthalmol Strabismus<\/jats:italic>\n                        . 2023;60(2):139\u2013146.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/01913913-20220428-01","type":"journal-article","created":{"date-parts":[[2022,5,25]],"date-time":"2022-05-25T06:21:00Z","timestamp":1653459660000},"page":"139-146","source":"Crossref","is-referenced-by-count":7,"title":["Accuracy of Intraocular Lens Power Calculation Formulas in Patients With Multifocal Intraocular Lens Implantation With Optic Capture in Berger Space for Pediatric Cataract"],"prefix":"10.3928","volume":"60","author":[{"given":"Menghan","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongfang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheng","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinyan","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusen","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_1023_17"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000324"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00220-7"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.85.8.939"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.07.019"},{"issue":"4","key":"e_1_3_2_7_2","first-page":"473","article-title":"Refractive accuracy after intraocular lens implantation in pediatric cataract","volume":"5","author":"Long T","year":"2012","unstructured":"Long T, Huang YS, Xie LX. Refractive accuracy after intraocular lens implantation in pediatric cataract. Int J Ophthalmol. 2012;5(4):473\u2013477. PMID:22937508","journal-title":"Int J Ophthalmol"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.07.002"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2010.183566"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(98)00247-5"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2006.01446.x"},{"key":"e_1_3_2_12_2","unstructured":"Trivedi RH Jr. Wilson MEJr. Selecting intraocular lens power in children. EyeNet Magazine. Published 2006. https:\/\/www.aao.org\/eyenet\/article\/selecting-intraocular-lens-power-in-children"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30031-1"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80659-1"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.07.022"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_522_19"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_1588_21"},{"issue":"5","key":"e_1_3_2_18_2","first-page":"343","article-title":"[Preliminary clinical observations of the effect of posterior continuous curvilinear capsulorhexis with intraocular lens optic capture in the treatment of pediatric cataract]","volume":"56","author":"Dong XJ","year":"2020","unstructured":"Dong XJ, Ge JJ, Huang YS. [Preliminary clinical observations of the effect of posterior continuous curvilinear capsulorhexis with intraocular lens optic capture in the treatment of pediatric cataract]. Zhonghua Yan Ke Za Zhi. 2020;56(5):343\u2013348. PMID:32450666","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210225-01"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.08.015"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1159\/000351653"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-014-2571-0"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-016-0232-5"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.10.036"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30045-1"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.036"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80049-1"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.4274\/balkanmedj.2017.1504"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00595-4"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.12.031"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-020-04617-8"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.06.063"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2007.10.012"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80917-0"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.06.042"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.013"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31821cc4d6"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.4103\/0301-4738.149131"}],"container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T20:02:58Z","timestamp":1782763378000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01913913-20220428-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,1]]},"references-count":37,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,3,1]]}},"alternative-id":["10.3928\/01913913-20220428-01"],"URL":"https:\/\/doi.org\/10.3928\/01913913-20220428-01","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,1]]}}}