{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T09:53:34Z","timestamp":1794650014602,"version":"4.9.1"},"reference-count":40,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To compare the influence of total keratometry (TK) versus anterior keratometry (K) measured with the swept-source optical biometer IOLMaster 700 (Carl Zeiss Meditec AG) on the planning of toric intraocular lenses (IOLs), and the error in predicted residual astigmatism (PRA).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This single-center retrospective study included 247 eyes of 180 patients. In eyes undergoing cataract surgery, the optimal toric IOL was calculated based on K or TK measured with the IOLMaster 700. Two formulas were used to estimate IOL power: Holladay and Barrett Toric. Optimal cylinder power and alignment axis change induced by using TK versus K were reported. PRA by each calculation method was compared with manifest refractive astigmatism. Postoperative refractive astigmatism prediction error was calculated using vector analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              The optimal toric IOL based on TK compared with K was different in 39.3% of cases with the Holladay formula and 31.6% of cases with the Barrett Toric formula. The use of TK rather than K reduced the centroid error in PRA when calculated with the Holladay formula (\n              <jats:italic>P<\/jats:italic>\n              &lt; .001), but not when calculated with the Barrett Toric formula (\n              <jats:italic>P<\/jats:italic>\n              = .19). The against-the-rule astigmatism subgroup analysis with the Barrett Toric formula showed a statistically significant decrease of centroid error in PRA with the use of TK compared with K (\n              <jats:italic>P<\/jats:italic>\n              = .01).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>TK compared with K measured with the IOL-Master 700 resulted in a change of optimal toric IOL in almost one-third of cases and decreased the error in PRA in patients with against-the-rule astigmatism.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Refract Surg<\/jats:italic>\n                . 2023;39(4):257\u2013264.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/01913913-20230125-01","type":"journal-article","created":{"date-parts":[[2023,4,11]],"date-time":"2023-04-11T16:08:52Z","timestamp":1681229332000},"page":"257-264","source":"Crossref","is-referenced-by-count":4,"title":["Total Keratometry Measured With a Swept-Source Optical Biometer Versus Anterior Keratometry: From Planning to Postoperative Results"],"prefix":"10.3928","volume":"39","author":[{"given":"Mickael","family":"Anjou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antoine","family":"Brezin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominique","family":"Monnet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2018-312025"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)74917-7"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.01.031"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.09.010"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000560"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.10.002"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2014.3602"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20140429-01"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.06.048"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2015.01.022"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-15903"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.06.027"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.06.040"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2013.04.035"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-019-04570-1"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000001343"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.10.041"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090917-07"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.02.038"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.08.036"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S213132"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20171004-03"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.12.031"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00796-3"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2008.01287.x"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.07.027"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-019-0489-9"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-15659"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.08.036"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.04.039"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190422-02"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-020-05046-3"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090101-04"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S149709"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2021.05.028"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180214-02"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2022.02.029"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-012-0117-8"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-020-01245-8"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.03.030"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,7,25]],"date-time":"2023-07-25T17:45:27Z","timestamp":1690307127000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01913913-20230125-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4]]},"references-count":40,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,4]]}},"alternative-id":["10.3928\/01913913-20230125-01"],"URL":"https:\/\/doi.org\/10.3928\/01913913-20230125-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,4]]}}}