{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T05:39:26Z","timestamp":1785476366731,"version":"3.56.0"},"reference-count":5,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Pediatr Ophthalmol Strabismus"],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To determine normal threshold values for the 24-2 program of the VisuALL-K (Olleyes, Inc), a portable static automated virtual reality perimeter that uses a video game\u2013based testing modality on an updated version of the algorithm and to repeat the test to assess retest variability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This prospective cohort study included 19 participants (aged 8 to 17 years) with healthy afferent systems. Participants performed two 24-2 automated perimetry tests on the virtual reality perimeter device.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Mean age was 12.7 \u00b1 2.5 years; 53% were boys and 47% were girls. Mean test location threshold was 30.5 \u00b1 4.0 dB for test 1 and 31.3 \u00b1 2.8 dB for test 2. Sensitivity decreased with eccentricity as expected (\u22120.17 dB per degree). Bland-Altman analysis showed a repeatability coefficient of \u00b15.1 dB for mean deviation, meaning that 95% of retest values were within \u00b15 dB of the threshold value for the first test. Higher thresholds for the first test regressed toward the mean values in the second test, indicating a learning effect. Intraclass correlation coefficient for mean deviation between test 1 and test 2 was 0.70 (0.55 to 0.80,\n              <jats:italic>P<\/jats:italic>\n              &lt; .0001). Mean time to completion for the virtual reality perimeter was 5.1 \u00b1 1.5 min\/eye.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The VisuALL-K virtual reality perimeter provided an assessment of the visual field in normal children aged 8 to 17 years. A shallow hill of vision was demonstrated. A notable learning effect was demonstrated, with repeatability difference wider than other published head-mounted display perimeters.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>J Pediatr Ophthalmol Strabismus<\/jats:italic>\n                . 2024:61(4):262\u2013266.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/01913913-20240118-03","type":"journal-article","created":{"date-parts":[[2024,2,21]],"date-time":"2024-02-21T13:53:07Z","timestamp":1708523587000},"page":"262-266","source":"Crossref","is-referenced-by-count":4,"title":["Accuracy and Reproducibility of Virtual Reality Perimetry in Children"],"prefix":"10.3928","volume":"61","author":[{"given":"Jaron K.","family":"Pruett","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward F.","family":"Linton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean P.","family":"Donahue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sylvia L.","family":"Groth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.12.1.6"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.10.3.20"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.12.9.19"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.xops.2021.100105"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2023.3249045"}],"container-title":["Journal of Pediatric Ophthalmology &amp; Strabismus"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T11:49:37Z","timestamp":1721821777000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/01913913-20240118-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7]]},"references-count":5,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,7]]}},"alternative-id":["10.3928\/01913913-20240118-03"],"URL":"https:\/\/doi.org\/10.3928\/01913913-20240118-03","relation":{},"ISSN":["0191-3913","1938-2405"],"issn-type":[{"value":"0191-3913","type":"print"},{"value":"1938-2405","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7]]}}}