{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T14:53:31Z","timestamp":1758639211222},"reference-count":15,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[1995,1]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>BACKGROUND: Topography measures the centration in refractive and corneal refractive surgery, but until recently there was no effective method to measure decentration in intraocular lens (IOL) implantation.<\/jats:p>\n          <jats:p>PATIENTS AND METHODS: We measured the decentration of 22 phakic eyes, in 14 high myopic patients, based upon photographs of the anterior segment using a digital analysis system (IMAGEnet Topcon Corporation 1988, Tokyo, Japan). These eyes had undergone IOL implantation for the correction of myopia with Worst-Fechner iris claw lenses. Decentration was measured with respect to the centers of both the cornea and pupil.<\/jats:p>\n          <jats:p>RESULTS: Mean decentration of the IOL center from the cornea center was 0.51 \u00b1 0.25 mm (range, 0 to 0.8374 mm). When measured with respect to the center of the pupil, the average decentration was 0.47 \u00b1 0.29 mm (range, 0.182 to 0.9341 mm). A positive correlation between the decentration measurements of the two methods was found (p &lt; .01 indicated statistical significance).<\/jats:p>\n          <jats:p>CONCLUSIONS: This digital imaging system (IMAGEnet) accurately measured decentration of IOLs in myopic eyes. [J Refract Surg. 1995;11:26-30.]<\/jats:p>","DOI":"10.3928\/1081-597x-19950101-08","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T03:37:27Z","timestamp":1619062647000},"page":"26-66","source":"Crossref","is-referenced-by-count":18,"title":["Digital System Measurement of Decentration of Worst-Fechner Iris Claw Myopia Intraocular Lens"],"prefix":"10.3928","volume":"11","author":[{"given":"Vicente T","family":"P\u00e9rez-Torregrosa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jos\u00e9 L","family":"Menezo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miguel A","family":"Harto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miguel J","family":"Maldonado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angel","family":"Cisneros","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Solomon KD Apple DJ Mamalis N et al. Complications of intraocular lenses with special reference to an analysis of 2500 explanted intraocular lenses (IOLs). European Journal of Implant and Refractive Surgery. 1991;3:193-200.","DOI":"10.1016\/S0955-3681(13)80482-0"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Hansen SO Tetz ME Solomon KD et al. Decentration of flexible loop posterior chamber intraocular lenses in a series of 222 postmortem eyes. Ophthalmology. 1988;95:344-349.","DOI":"10.1016\/S0161-6420(88)33178-7"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Assia EI Legier UFC Merrill C et al. Clinicopathologic study of the effect of radial tears and loop fixation on intraocular lens decentration. Ophthalmology. 1993;100:153-158.","DOI":"10.1016\/S0161-6420(93)31677-5"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Sasaki K Sakamoto Y Shibata T et al. Measurement of postoperative intraocular lens tilting and decentration using Scheimpfiug images. J Cataract Refract Surg. 1989;15:454-457.","DOI":"10.1016\/S0886-3350(89)80071-9"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Phillips P Rosskothen HD P\u00e9rez-Emanuelli J et al. Measurement of intraocular lens decentration and tilt in vivo. J Cataract Refract Surg. 1988;14:129-135.","DOI":"10.1016\/S0886-3350(88)80086-5"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Caballero A Losada M L\u00f3pez JM et al. Decentration of intraocular lenses implanted after intercapsular cataract extraction (envelope technique). J Cataract Refract Surg. 1991;17:330-334.","DOI":"10.1016\/S0886-3350(13)80830-9"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Colvard DM Dunn SA. Intraocular lens centration with continuous tear capsulotomy. J Cataract Refract Surg. 1990;16:312-314.","DOI":"10.1016\/S0886-3350(13)80700-6"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Wasserman D Apple DJ Casta\u00f1eda VE et al. Anterior capsular tears and loop fixation of posterior camber intraocular lenses. Ophthalmology. 1991;98:425-431.","DOI":"10.1016\/S0161-6420(91)32274-7"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Fechner PU Worst JG. A new concave intraocular lens for the correction of myopia. European Journal of Implant and Refractive Surgery. 1989;1:41-43.","DOI":"10.1016\/S0955-3681(89)80034-6"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Van der Heijde GL Fechner PU Worst JG. Optische konsequenzen der implantation einer negative intraokularlinse bei myopen patien. Klin Monatsbl Augenheilkd. 1988;193:99-102.","DOI":"10.1055\/s-2008-1050231"},{"key":"e_1_3_1_12_1","unstructured":"11. Harto M Cisneros A P\u00e9rez-Gil L Menezo JL. LIO de Worst-Fechner para la correcci\u00f3n de alta miop\u00eda en ojos faquicos. Archives Socieded Espa\u00f1ola de Oftalmologe. 1992;62:267-274."},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Fechner PU Van der Heijde GL Worst JG. The correction of myopia by lens implantation into phakic eyes. Am J Ophthalmol. 1989;107:659-663.","DOI":"10.1016\/0002-9394(89)90264-X"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. McDonnell PJ Spalton DJ Falcon MG. Decentration of the posterior chamber lens implant: the effect of optic size on the incidence of visual aberrations. Eye. 1990;4:132-137.","DOI":"10.1038\/eye.1990.17"},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Auran JD Koester CJ Donn A. In vivo measurement of posterior chamber intraocular lens decentration and tilt. Arch Ophthalmol. 1990;108:75-79.","DOI":"10.1001\/archopht.1990.01070030081033"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Kozaki J Tanihara H Yasuda A Cagata M. Tilt and decentration of the implanted posterior chamber intraocular lens. J Cataract Refract Surg. 1991;17:592-595.","DOI":"10.1016\/S0886-3350(13)81046-2"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T12:15:06Z","timestamp":1683116106000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081-597X-19950101-08"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,1]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1995,1]]}},"alternative-id":["10.3928\/1081-597X-19950101-08"],"URL":"https:\/\/doi.org\/10.3928\/1081-597x-19950101-08","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[1995,1]]}}}