{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T08:38:29Z","timestamp":1794645509369,"version":"4.9.1"},"reference-count":20,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[1995,1]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>BACKGROUND: Photorefractive keratectomy relies on precise ablation of cornea stromal tissue to achieve a desired change in refraction. The routine technique for photorefractive keratectomy has been manual debridement of the epithelium prior to performing excimer laser ablation. We investigated whether laser ablation versus manual debridement of the corneal epithelium influences the refractive result.<\/jats:p>\n          <jats:p>METHODS: A retrospective matched controlled study analyzing the refractive outcome of 46 eyes after excimer laser photorefractive keratectomy was performed. Half of the eyes had the corneal epithelium ablated with the excimer laser, while the other half had mechanical removal. Topical postoperative corticosteroid dosing was different in the two groups. All photorefractive keratectomies were performed by the same surgeon (H.V.G.). The two groups were analyzed for statistical differences in refractive outcomes and corneal haze after 6 months.<\/jats:p>\n          <jats:p>RESULTS: The mean preoperative spherical equivalent refraction in the laser removal group was -5.11 diopters (D), and -5.09 D in the manual group. At 6 months postoperatively, the mean spherical equivalent refraction in the laser group was +0.03 D and -0.40 D for the manual group (p = .21). At no point postoperatively was there any significant difference in the mean refractive outcome or variance of the refractive results between the two groups, although there was a trend toward greater correction with laser ablation of epithelium. There was no statistical difference in the amount of stromal haze by slit-lamp microscopy in the two different debridement groups. There was no significant difference in final uncorrected visual acuity, rate of reepithelialization, or reported incidence of halos or glare between the two groups.<\/jats:p>\n          <jats:p>CONCLUSION: There was a tendency toward greater refractive correction at 6 months using the laser for corneal epithelial removal than manual debridement, although the difference was not statistically significant. The trend toward slightly higher correction emphasizes the need for care when removing epithelium with the laser to prevent concomitant stromal ablation. [J Refract Surg. 1995;11:36-41.]<\/jats:p>","DOI":"10.3928\/1081-597x-19950101-10","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T03:37:27Z","timestamp":1619062647000},"page":"36-67","source":"Crossref","is-referenced-by-count":49,"title":["Comparison of Laser and Manual Removal of Corneal Epithelium for Photorefractive Keratectomy"],"prefix":"10.3928","volume":"11","author":[{"given":"Howard V","family":"Gimbel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian M","family":"DeBroff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert A","family":"Beldavs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John A van","family":"Westenbrugge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Ferensowicz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Trokel SL Srinivasan R Braren B. Excimer laser surgery of the cornea. Am J Ophthalmol. 1983;96:710-715.","DOI":"10.1016\/S0002-9394(14)71911-7"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Marshall J Trokel S Rother S Schubert H. An ultrastructural study of corneal incisions induced by an excimer laser at 193 rum. Ophthalmology. 1985;92:749-758.","DOI":"10.1016\/S0161-6420(85)33961-1"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3 . McDonald MB Liu JC Byrd TJ et al. Central photorefractive keratectomy for myopia: partially sighted and normally sighted eyes. Ophthalmology. 1991;98:1327-1337.","DOI":"10.1016\/S0161-6420(91)32128-6"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Seiler T Wollensak J. Myopic photorefractive keratectomy with the excimer laser. One year follow-up. Ophthalmology. 1991;98:1156-1163.","DOI":"10.1016\/S0161-6420(91)32157-2"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Gartry DS Kerr-Muir MG Marshall J Photorefractive keratectomy with an argon fluoride excimer laser: a clinical study. J Refract Corneal Surg. 1991;7:420-435.","DOI":"10.3928\/1081-597X-19911101-06"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Gartry DS Kerr-Muir MG Marshall J. Excimer laser photorefractive keratectomy: 18-month follow-up. Ophthalmology. 1992;99:1209-1219.","DOI":"10.1016\/S0161-6420(92)31821-4"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. SaIz JJ Maguen E Macy JI et al. One-year results of excimer laser photorefractive keratectomy for myopia. J Refract Corneal Surg. 1992;8:269-273.","DOI":"10.3928\/1081-597X-19920701-05"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. SaIz JJ Maguen E Nesburn AB et al. A two-year experience with laser photorefractive keratectomy for myopia. Ophthalmology. 1993;100:873-882.","DOI":"10.1016\/S0161-6420(93)31560-5"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Tengroth B Epstein D Fagerholm P et al. Excimer laser photorefractive keratectomy for myopia: clinical results in sighted eyes. Ophthalmology. 1993;100:739-746.","DOI":"10.1016\/S0161-6420(93)31581-2"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Piebenga LW Matta CS Deitz MR et al. Excimer photorefractive keratectomy for myopia. Ophthalmology. 1993;100:1335-1345.","DOI":"10.1016\/S0161-6420(13)31819-3"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Litwin KL Moreira H Ohadi McDonnell PJ. Changes in corneal curvature at diff\u00e8rent excimer laser ablative depths. Am J Ophthalmol. 1991;11:382-384.","DOI":"10.1016\/S0002-9394(14)72335-9"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Marshall J Trokel S Rothery S Krueger RR. A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser. Br J Ophthalmol. 1986;70:482-501.","DOI":"10.1136\/bjo.70.7.482"},{"key":"e_1_3_1_14_1","unstructured":"13. Marshall J Trokel S Rothery S Krueger RR. Photoablative reprofiling of the cornea using an excimer laser photorefractive keratectomy. Lasers and Light in Ophthalmology. 1986;1:21-48."},{"key":"e_1_3_1_15_1","doi-asserted-by":"crossref","unstructured":"14. Puliafito CA Wong K Steinert RF. Quantitative and ultrastructural studies of excimer ablation of the cornea at 193 and 248 nanometers. Lasers Surg Med. 1987;7:155-159.","DOI":"10.1002\/lsm.1900070203"},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Ishikawa T del Cerroo M Liang P Kim J1 Aquavella J. Hypersensitivity following excimer laser ablation through the corneal epithelium. J Refract Corneal Surg. 1992;8: 466-473.","DOI":"10.3928\/1081-597X-19921101-13"},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Tanelian D Beuerman R. Responses of rabbit corneal nociceptors to mechanical and thermal stimulation. Exp Neurol. 1984;84:165-178.","DOI":"10.1016\/0014-4886(84)90013-X"},{"key":"e_1_3_1_18_1","unstructured":"17. Tuft S Al-Dhahir R Dyer P Zahao Z. Characterization of the fluorescence spectra produced by excimer laser irradiation of the cornea. Invest Ophthalmol Vis Sci. 1990;31:1512-1518."},{"key":"e_1_3_1_19_1","unstructured":"18. Summit Technology. IAC Excimed UV100LA Laser System Canadian Clinical Investigators Manual; Jan 1991."},{"key":"e_1_3_1_20_1","unstructured":"19. Casey TA Mayer DJ. Corneal Grafting Principles and Practice 1st ed. Philadelphia Pa: WB Saunders Company; 1984:17."},{"key":"e_1_3_1_21_1","doi-asserted-by":"crossref","unstructured":"20. McDonald MB Frantz JM Klyce SD Salmer\u00f3n B et al. One-year refractive results of central photorefractive keratectomy for myopia in the non-human primate cornea. Arch Ophthalmol. 1990;108:40-47.","DOI":"10.1001\/archopht.1990.01070030046026"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T12:14:33Z","timestamp":1683116073000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081-597X-19950101-10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,1]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1995,1]]}},"alternative-id":["10.3928\/1081-597X-19950101-10"],"URL":"https:\/\/doi.org\/10.3928\/1081-597x-19950101-10","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[1995,1]]}}}