{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T17:55:29Z","timestamp":1774979729864,"version":"3.50.1"},"reference-count":10,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[1998,9]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>BACKGROUND: Phakic intraocular lens (IOL) implantation represents a major technique for the correction of high myopia. The STAAR collamer posterior chamber phakic IOL- trade named Implantable Contact Lens- is an emerging technology in refractive surgery. We studied the relative position of the posterior chamber phakic IOL using ultrasound biomicroscopy.<\/jats:p>\n          <jats:p>METHODS: The posterior chamber phakic intraocular lens was inserted in 9 eyes of 8 patients with high myopia. Ultrasound biomicroscopy was performed before and after implantation of the phakic IOL to assess its relative position in the anterior segment of the eye. The parameters measured and compared were anterior chamber depth, angle opening distance 500 urn from the scleral spur, iris-crystalline lens contact distance, iris-IOL contact distance, and K)L- crystal Ii ne lens distance.<\/jats:p>\n          <jats:p>RESULTS: Ultrasound biomicroscopy showed contact between the iris and the IOL in all eyes and between the IOL and the crystalline lens in 8 eyes. Reduction in the anterior chamber depth and localized narrowing of the angle opening were observed in all eyes.<\/jats:p>\n          <jats:p>CONCLUSION: IOL-iris touch, IOL-crystalline lens touch, and anterior chamber shallowing raise concerns of pigmentary dispersion, cataractogenesis, and narrow angle glaucoma following posterior chamber phakic intraocular lens implantation. Clinical data are needed to determine if these problems occur. [J Refract Surg 1998;14:497-503]<\/jats:p>","DOI":"10.3928\/1081-597x-19980901-06","type":"journal-article","created":{"date-parts":[[2021,4,20]],"date-time":"2021-04-20T10:01:51Z","timestamp":1618912911000},"page":"497-503","source":"Crossref","is-referenced-by-count":67,"title":["Ultrasound Biomicroscopic Imaging of Posterior Chamber Phakic Intraocular Lens"],"prefix":"10.3928","volume":"14","author":[{"given":"Fernando","family":"Trindade","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frederico","family":"Pereira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebasti\u00e3o","family":"Cronemberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Assetto V Benedetti S Pesando P. Collamer intraocular contact lens to correct high myopia. J Cataract Refract Surg 1996;22:551-556.","DOI":"10.1016\/S0886-3350(96)80007-1"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Pavlin CJ Sherar MD Foster FS. Subsurface ultrasound microscopic imaging of the intact eye. Ophthalmology 1990;97:244-250.","DOI":"10.1016\/S0161-6420(90)32598-8"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Pavlin CJ Harasiewicz K Foster FS. Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol 1992;113:381-389.","DOI":"10.1016\/S0002-9394(14)76159-8"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Pavlin CJ Harasiewicz K Sherar MD Foster FS. Clinical use of ultrasound biomicroscopy. Ophthalmology 1991;98:287-295.","DOI":"10.1016\/S0161-6420(91)32298-X"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Pavlin CJ Rootman D Arshinoff S Harasiewicz K Foster FS. Determination of haptic position of transcl erally fixated posterior chamber intraocular lenses by ultrasound biomicroscopy. J Cataract Refract Surg 1993;19:573-577.","DOI":"10.1016\/S0886-3350(13)80002-8"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Pavlin CJ. Harasiewicz K Foster FS. Ultrasound biomicroscopic analysis of haptic position in late-onset recurrent hyphema after posterior chamber lens implantation. J Cataract Refract Surg 1994;20:182-185.","DOI":"10.1016\/S0886-3350(13)80162-9"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Tello C Chi T Liebmann J. Ritch R. Ultrasound biomicroscopy in Pseudophakie malignant glaucoma. Ophthalmology 1993;100:1330-1334.","DOI":"10.1016\/S0161-6420(93)31479-X"},{"key":"e_1_3_1_9_1","unstructured":"8. Pavlin CJ Macken P Trope G Feldman F Harasiewicz K Foster FS. Ultrasound biomicroscopic features of pigmentary glaucoma. Can J Ophthalmol 1994;29:187-192."},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Bezzina A. Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes [letterl. Am J Ophthalmol 1992;114:516-517.","DOI":"10.1016\/S0002-9394(14)71878-1"},{"key":"e_1_3_1_11_1","unstructured":"10. Tello C. Liebmann J Potash SD Cohen H Ritch R. Measurement of ultrasound biomicroscopy images: intraobserver and interobserver reliability. Invest Ophthalmol Vis Sci 1994;35: 3549-3552."}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T10:04:27Z","timestamp":1683108267000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081-597X-19980901-06"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998,9]]},"references-count":10,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1998,9]]}},"alternative-id":["10.3928\/1081-597X-19980901-06"],"URL":"https:\/\/doi.org\/10.3928\/1081-597x-19980901-06","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[1998,9]]}}}