{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T13:28:04Z","timestamp":1758634084307},"reference-count":19,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2004,1]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>PURPOSE: We investigated long-term efficacy, predictability, stability, and safety of diode laser thermal keratoplasty (DTK) to correct hyperopia.<\/jats:p>\n          <jats:p>METHODS: DTK was performed on 24 eyes (18 patients). Eight eyes with high hyperopia (mean +4.75 \u00b1 0.63 D; range +3.50 to +5.50 D) received 12 pairs of coagulation spots at 6-mm and 7-mm treatment zone diameters; eight eyes with low hyperopia (mean +2.25 \u00b1 0.40 D; range +1.50 to +2.75 D) received eight coagulation spots at 8 mm, and eight eyes with low hyperopia (mean +1.50 \u00b1 0.46 D; range +1.25 to +2.25 D) were treated to induce mild myopia (-1.50 D) in the non-dominant eye for monovision using eight pairs of spots at 7 and 8-mm diameters. Minimum follow-up was 18 months.<\/jats:p>\n          <jats:p>RESULTS: Mean decrease in cycloplegic refraction at 18 months was 5.00 \u00b1 0.38 D in the high hyperopia group, 1.75 \u00b1 0.19 D in the low hyperopia group, and 3.25 \u00b1 0.27 D in the presbyopia group. Mean increase in uncorrected visual acuity (UCVA) at 18 months was 8.125 \u00b1 2.1 Snellen lines in the high hyperopia group, 6.625 \u00b1 0.744 lines for low hyperopia; decrease of 1.00 \u00b1 1.85 line occcurrd in the presbyopia group. Near UCVA in the presbyopia group improved by 3.875 \u00b1 0.83 Jaeger lines. Best spectacle-corrected visual acuity (BSCVA) was restored by 3 months in all eyes.<\/jats:p>\n          <jats:p>CONCLUSION: DTK was an effective and fairly safe procedure, with reasonable predictability and stability. Nomograms for laser energy level, treatment zone diameter, and number of spots need improvement. [J Refract Surg 2004;20:53-61]<\/jats:p>","DOI":"10.3928\/1081-597x-20040101-10","type":"journal-article","created":{"date-parts":[[2019,12,17]],"date-time":"2019-12-17T19:29:48Z","timestamp":1576610988000},"page":"53-61","source":"Crossref","is-referenced-by-count":7,"title":["Diode Laser Thermal Keratoplasty to Correct Hyperopia"],"prefix":"10.3928","volume":"20","author":[{"given":"Uri","family":"Rehany","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elina","family":"Landa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Davis EA Hardten DR Lindstrom RL. LASIK complications. Int Ophthalmol Clin 2000;40:67-75.","DOI":"10.1097\/00004397-200007000-00009"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Ambrosio R Wilson SE. Complications of laser in situ keratomileusis: Etiology prevention and treatment. J Refract Surg 2001;17:350-379.","DOI":"10.3928\/1081-597X-20010501-09"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Davidorf JM Zaldivar R Oscherow S. Results and complications of laser in situ keratomileusis by experienced surgeons. J Refract Surg 1998;14:114-122.","DOI":"10.3928\/1081-597X-19980301-09"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Ibrahim D. Laser in situ keratomileusis for hyperopia and hyperopic astigmatism. J Refract Surg 1998;14(suppl 2):S179-S182.","DOI":"10.3928\/1081-597X-19980401-07"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Knorz MC Leirmann A Jendritza B Hugger P. LASIK for hyperopia and hyperopic astigmatism - results of a pilot study. Semin Ophthalmol 1998;13:83-87.","DOI":"10.3109\/08820539809059823"},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Alio JL Ismail MM Sanchez -Pego JL. Correction of hyperopia with non-contact Ho:YAG laser thermal keratoplasty. J Refract Surg 1997;13:17-22.","DOI":"10.3928\/1081-597X-19970101-07"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Eggink CA Meurs P Bardak Y Deutman AF. Holmium laser thermal keratoplasty for hyperopia and astigmatism after photorefractive keratectomy. J Refract Surg 2000; 16: 317-322.","DOI":"10.3928\/1081-597X-20000501-04"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Eggink CA Bardak Y Cuypers MH Deutman AF. Treatment of hyperopia with contact Ho: YAG laser thermal keratoplasty. J Cataract Refract Surg 1999;15:16-22.","DOI":"10.3928\/1081-597X-20000501-04"},{"key":"e_1_3_1_10_1","unstructured":"9. Portellinha W Nakano K Oliveira M Simoceli R. Laser in situ keratomileusis for hyperopia after thermal keratoplasty. J Cataract Refract Surg 1999;15:S218-S220."},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Vinciguerra P Kohnen T Azzolini M Radice P Epstein D Koch DD. Radial and staggered treatment patterns to correct hyperopia using non-contact holmium:YAG laser thermal keratoplasty. J Cataract Refract Surg 1998;24:21-30.","DOI":"10.1016\/S0886-3350(98)80070-9"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Parel JM Ren QS. Non-contact laser photothermal keratoplasty. Biophysical principles and laser beam delivery system. J Refract Corneal Surg 1994;10:511-518.","DOI":"10.3928\/1081-597X-19940901-08"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Berry MJ Fredlin LG Menefee R Valderrama GL. Temperature distribution in laser-irradiated corneas. Invest Ophthalmol Vis Sci 1996;103:731-740.","DOI":"10.1016\/S0161-6420(96)30622-2"},{"key":"e_1_3_1_14_1","unstructured":"13. Ayala Espinosa MJ Alio Y Sanz J Ismail MM Sanchez-Castro P. [Experimental corneal histological study after thermo keratoplasty with laser]. Arch Soc Esp Oftalmol 2000;75:619-626."},{"key":"e_1_3_1_15_1","unstructured":"14. Jean B Matallana M Berlin MS Bende T. Depth adjustable handpiece for thermokeratoplasty. Invest Ophthalmol Vis Sci 1996;37:S570."},{"key":"e_1_3_1_16_1","unstructured":"15. Jean B Oltrup T Derse M Bende T. Hyperopia and astigmatism correction using a CW diode laser. Invest Ophthalmol Vis Sci 1997;38:S497."},{"key":"e_1_3_1_17_1","unstructured":"16. Bende T Jean B Oltrup T. Laser thermal keratoplasty using a continuous wave diode laser. J Refract Surg 1999;15:154-158."},{"key":"e_1_3_1_18_1","unstructured":"17. Jean B Dockhorn V Oltrup T Bende T Bende M. Laser thermokeratoplasty (LTK) by using a CW dio delaser-results of a pilot study. Invest Ophthalmol Vis Sci 1998;39:S753."},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Koch CC Kohnen T McDonnell PJ Menefee RF Berry MJ. Hyperopia correction by non-contact holmium:YAG laser thermal keratoplasty. Ophthalmology 1996;103:1525-1535.","DOI":"10.1016\/S0161-6420(96)30466-1"},{"key":"e_1_3_1_20_1","doi-asserted-by":"crossref","unstructured":"19. Wirbelauer C Koop N Tuengler A Geerling G Biringruber R Laqua H Brinkman R. Corneal endothelium cell damage after experimental diode laser thermal keratoplasty. J Refract Surg 2000;16:323-329.","DOI":"10.3928\/1081-597X-20000501-05"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:06:18Z","timestamp":1683111978000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081-597X-20040101-10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,1]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2004,1]]}},"alternative-id":["10.3928\/1081-597X-20040101-10"],"URL":"https:\/\/doi.org\/10.3928\/1081-597x-20040101-10","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2004,1]]}}}