{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T08:20:43Z","timestamp":1761294043547},"reference-count":9,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2004,11]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>PURPOSE: To describe the optical implications of the aberration pattern of a keratoconic eye implanted with an intrastromal corneal ring (Ferrara ring).<\/jats:p>\n          <jats:p>METHODS: A 32-year-old man with bilateral keratoconus had a Ferrara intrastromal corneal ring implanted in his right eye. Surgery was uneventful and both uncorrected (UCVA) and best spectacle-corrected (BSCVA) visual acuity improved. Corneal topography was performed before and after surgery. Wavefront measurements were performed 1 month after the procedure in both eyes for comparison. The point spread function, modulation transfer function (MTF), and convolved acuity chart were analyzed.<\/jats:p>\n          <jats:p>RESULTS: The right eye-implanted with the intrastromal Ferrara ring-had high root-mean-square (RMS) values for higher order aberrations. The left eye-keratoconus without an intrastromal ring-had moderate values. Point spread function, MTF, and convolution acuity charts are presented for each eye, with the latter two showing improved visual function in the implanted eye, despite a higher aberration value.<\/jats:p>\n          <jats:p>CONCLUSION: The wavefront measurement device captured aberrations even in a highly aberrated eye. Despite better UCVA and BSCVA, the Ferrara ring notably increased higher order aberrations compared to the fellow eye, but with a more uniform central pattern. In this case, the larger RMS value was a poor predictor of good visual function; other metrics better predicted the patient's subjective response. Metrics other than RMS error may be necessary to better correlate aberration value with visual satisfaction in some eyes. [J Refract Surg 2004;20:823-830]<\/jats:p>","DOI":"10.3928\/1081-597x-20041101-11","type":"journal-article","created":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T17:27:40Z","timestamp":1576776460000},"page":"823-830","source":"Crossref","is-referenced-by-count":10,"title":["Wavefront Aberrations Associated With the Ferrara Intrastromal Corneal Ring in a Keratoconic Eye"],"prefix":"10.3928","volume":"20","author":[{"given":"Maria Regina","family":"Chalita","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald R","family":"Krueger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Rabinowitz YS. Keratoconus. Surv Ophthalmol 1998;42: 297-319.","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Colin J Cochener B Savary G Malet F Holmes-Higgin D. INTACS inserts for treating keratoconus. Ophthalmology 2001;108:1409-1414.","DOI":"10.1016\/S0161-6420(01)00646-7"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Siganos CS Kymionis GD Kartakis N Theodorakis MA Astyrakakis N Pallikaris IG. Management of keratoconus with INTACS. Am J Ophthalmol 2003;135:64-70.","DOI":"10.1016\/S0002-9394(02)01824-X"},{"key":"e_1_3_1_5_1","doi-asserted-by":"crossref","unstructured":"4. Siganos D Ferrara P Chatzinikolas K Bes sis N Papastergiou G. Ferrara intrastromal corneal rings for the correction of keratoconus. J Cataract Refract Surg 2002; 28:1947-1951.","DOI":"10.1016\/S0886-3350(02)01495-5"},{"key":"e_1_3_1_6_1","doi-asserted-by":"crossref","unstructured":"5. Munson K Hong X Thibos LN. Use of a Shack-Hartmann aberrometer to assess the optical outcome of corneal transplantation in a keratoconic eye. Optom Vis Sci 2001;78: 866-871.","DOI":"10.1097\/00006324-200112000-00008"},{"key":"e_1_3_1_7_1","unstructured":"6. Thibos LN Applegate RA. Assessment of optical quality. In: MacRae SM Krueger RR Applegate RA eds. Customized Corneal Ablation - The Quest for Super Vision first edition. Thorofare NJ: Slack Ine; 2001."},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Barbero S Marcos S Merayo-Loves J Moreno-Barriuso E. Validation of the estimation of corneal aberrations from video ker at ography in keratoconus. J Refract Surg 2002; 18:263-270.","DOI":"10.3928\/1081-597X-20020501-09"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Maeda N Fujikado T Kuroda T Mihashi T Hirohara Y Nishida K Watanabe H Tano Y. Wavefront aberrations measured with Hartmann-Shack sensor in patients with keratoconus. Ophthalmology 2002;109:1996-2003.","DOI":"10.1016\/S0161-6420(02)01279-4"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Applegate RA Sarver EJ Khemsara V. Are all aberrations equal? J Refract Surg 2002;18:S556-S560.","DOI":"10.3928\/1081-597X-20020901-12"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T10:01:42Z","timestamp":1683108102000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081-597X-20041101-11"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,11]]},"references-count":9,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2004,11]]}},"alternative-id":["10.3928\/1081-597X-20041101-11"],"URL":"https:\/\/doi.org\/10.3928\/1081-597x-20041101-11","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2004,11]]}}}