{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T14:44:32Z","timestamp":1783694672782,"version":"3.55.0"},"reference-count":31,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2005,11]]},"abstract":"<jats:p>ABSTRACT<\/jats:p>\n          <jats:p>PURPOSE: To determine the higher order aberrations following implantation of four foldable intraocular lens (IOL) designs.<\/jats:p>\n          <jats:p>METHODS: One hundred twenty-two eyes were randomly assigned to undergo implantation with one of four foldable IOL designs ? Collamer (STAAR Surgical, Monrovia, Calif), plate haptic silicone (STAAR Surgical), AcrySof (Alcon, Ft Worth, Tex), or the Sensar (Advanced Medical Optics, Santa Ana, Calif). All enrolled eyes underwent wavefront assessment using the Tracey Visual Function Analyzer (Tracey Technologies, Houston, Tex).<\/jats:p>\n          <jats:p>RESULTS: Preoperatively, no significant differences were noted in higher order aberrations between the four lens groups. No significant differences were noted among the plate haptic silicone, Sensar, or AcrySof lenses at 1 week or 1 month postoperatively, or among the Collamer, plate haptic silicone, or Sensar lenses, with regard to total higher order aberrations, although differences were observed in individual aberration terms. At 1 week and 1 month postoperatively, the Collamer IOL had significantly less higher order aberrations than the AcrySof lens (P&lt;.01). Significantly less third and fourth order aberrations, coma, trefoil, spherical aberration, and tetrafoil were observed postoperatively with the Collamer than the AcrySof IOL. There were no parameters where the AcrySof had significantly less optical aberrations than the Collamer.<\/jats:p>\n          <jats:p>CONCLUSIONS: The Collamer IOL design is associated with fewer higher order aberrations than the AcrySof lens. [J Refract Surg. 2005;21:716-721.]<\/jats:p>","DOI":"10.3928\/1081-597x-20051101-10","type":"journal-article","created":{"date-parts":[[2019,12,20]],"date-time":"2019-12-20T19:46:45Z","timestamp":1576871205000},"page":"716-721","source":"Crossref","is-referenced-by-count":13,"title":["A Comparison of Higher Order Aberrations Following Implantation of Four Foldable Intraocular Lens Designs"],"prefix":"10.3928","volume":"21","author":[{"given":"Robert G","family":"Martin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donald R","family":"Sanders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"crossref","unstructured":"1. Webb RH Penney CM Thompson KP. Measurement of ocular wavefront distortion with a spatially resolved refrac tometer. Appi Opt. 1992;31:3678-3686.","DOI":"10.1364\/AO.31.003678"},{"key":"e_1_3_1_3_1","doi-asserted-by":"crossref","unstructured":"2. Liang J Grimm B Goelz S Bille JF. Objective measurement of wave aberrations of the human eye with the use of a HartmannShack wave-front sensor. \/ Opt Soc Am A. 1994;11:1949-1957.","DOI":"10.1364\/JOSAA.11.001949"},{"key":"e_1_3_1_4_1","doi-asserted-by":"crossref","unstructured":"3. Liang J Williams DR Miller DT. Supernormal vision and highresolution retinal imaging through adaptive optics. \/ Opt Soc Am A Opt Image Sci Vis. 1997;14:2884-2892.","DOI":"10.1364\/JOSAA.14.002884"},{"key":"e_1_3_1_5_1","unstructured":"4. McLellan JS Marcos S Burns SA. Age-related changes in monochromatic wave aberrations of the human eye. Invest Ophthalmol Vis Sci. 2001;42:1390-1395."},{"key":"e_1_3_1_6_1","unstructured":"5. Guirao A Gonzalez C Redondo M Geraghty E Norrby S Artal P. Average optical performance of the human eye as a function of age in a normal population. Invest Ophthalmol Vis Sci. 1990;40:203-213."},{"key":"e_1_3_1_7_1","doi-asserted-by":"crossref","unstructured":"6. Porter J Guirao A Cox IG Williams DR. Monochromatic aberrations of the human eye in a large population. \/ Opt Soc Am A Opt Image Sci Vis. 2001;18:1793-1803.","DOI":"10.1364\/JOSAA.18.001793"},{"key":"e_1_3_1_8_1","doi-asserted-by":"crossref","unstructured":"7. Castej?n-Moch?n JF L?pez-Gil N Benito A Artal P. Ocular wave-front aberration statistics in a normal young population. Vision Res. 2002;42:1611-1617.","DOI":"10.1016\/S0042-6989(02)00085-8"},{"key":"e_1_3_1_9_1","doi-asserted-by":"crossref","unstructured":"8. Wang L Koch DD. Ocular higher-order aberrations in individuals screened for refractive surgery. \/ Cataract Refract Surg. 2003;29:1896-1903.","DOI":"10.1016\/S0886-3350(03)00643-6"},{"key":"e_1_3_1_10_1","doi-asserted-by":"crossref","unstructured":"9. Wang L Dai E Koch DD Nathoo A. Optical aberrations of the human anterior c ornea. \/ Cataract Refract Surg. 2003;29:1514-1521.","DOI":"10.1016\/S0886-3350(03)00467-X"},{"key":"e_1_3_1_11_1","doi-asserted-by":"crossref","unstructured":"10. Mrochen M Jankov M Bueeler M Seiler T. Correlation between corneal and total wavefront aberrations in myopic eyes. J Refract Surg. 2003;19:104-112.","DOI":"10.3928\/1081-597X-20030301-04"},{"key":"e_1_3_1_12_1","doi-asserted-by":"crossref","unstructured":"11. Wang Y Zhao K Jin Y Niu Y Zuo T. Changes of higher order aberrations with various pupil sizes in the myopic eye. J Refract Surg. 2003;19:S270-S274.","DOI":"10.3928\/1081-597X-20030302-21"},{"key":"e_1_3_1_13_1","doi-asserted-by":"crossref","unstructured":"12. Seiler T Kaemmerer M Mierdel P Krinke HE. Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism. Arch Ophthalmol. 2000;118:17-21.","DOI":"10.1001\/archopht.118.1.17"},{"key":"e_1_3_1_14_1","doi-asserted-by":"crossref","unstructured":"13. Hong X Thibos LN. Longitudinal evaluation of optical aberrations following laser in situ keratomileusis surgery. \/ Refract Surg. 2000;16:S647-S650.","DOI":"10.3928\/1081-597X-20000901-32"},{"key":"e_1_3_1_15_1","unstructured":"14. Moreno -Barrius o E Merayo Lio ves J Marcos S Navarro R Ll?rente L Barbero S. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci. 2001;42:1396-1403."},{"key":"e_1_3_1_16_1","doi-asserted-by":"crossref","unstructured":"15. Pallikaris IG Kymionis GD Panagopoulou SI S?ganos CS Theodorakis MA Pallikaris AI. Induced optical aberrations following formation of a laser in situ keratomileusis flap. \/ Cataract Refract Surg. 2002;28:1737-1741.","DOI":"10.1016\/S0886-3350(02)01507-9"},{"key":"e_1_3_1_17_1","doi-asserted-by":"crossref","unstructured":"16. Hersh PS Fry K B laker JW. Spherical aberration after laser in situ keratomileusis and photorefractive keratectomy. Clinical results and theoretical models of etiology. \/ Cataract Refract Surg. 2003;29:2096-2104.","DOI":"10.1016\/j.jcrs.2003.09.008"},{"key":"e_1_3_1_18_1","doi-asserted-by":"crossref","unstructured":"17. Miller JM Anwaruddin R Straub J Schwiegerling J. Higher order aberrations in normal dilated intraocular lens and laser in situ keratomileusis corneas. J Refract Surg. 2002;18:S579-S583.","DOI":"10.3928\/1081-597X-20020901-16"},{"key":"e_1_3_1_19_1","doi-asserted-by":"crossref","unstructured":"18. Barbero S Marcos S Jimenez- Alfar o I. Optical aberrations in intraocular lenses measured in vivo and in vitro. \/ Opt Soc Am A Opt Image Sci Vis. 2003;20:1841-1851.","DOI":"10.1364\/JOSAA.20.001841"},{"key":"e_1_3_1_20_1","doi-asserted-by":"crossref","unstructured":"19. Vilarrondona L Barrett GD Johnson B. High-order aberrations in pseudophakia with different intraocular lenses. \/ Cataract Refract Surg. 2004;30:571-575.","DOI":"10.1016\/j.jcrs.2003.12.041"},{"key":"e_1_3_1_21_1","doi-asserted-by":"crossref","unstructured":"20. Kramer CY. Extension of multiple range test to group means with unequal numbers of replications. Biometrics. 1956;12:307-310.","DOI":"10.2307\/3001469"},{"key":"e_1_3_1_22_1","doi-asserted-by":"crossref","unstructured":"21. Tester R Pace NL Samore M Olson RJ. Dysphotopsia in phakic and Pseudophakie patients: incidence and relation to intraocular lens type (2). \/ Refract Surg. 2000;26:810-816.","DOI":"10.1016\/S0886-3350(00)00427-2"},{"key":"e_1_3_1_23_1","doi-asserted-by":"crossref","unstructured":"22. Farbowitz MA Zabriskie NA Crandall AS Olson RJ Miller KM. Visual complaints associated with the AcrySof acrylic intraocular lens (1). \/ Cataract Refract Surg. 2000;26:1339-1345.","DOI":"10.1016\/S0886-3350(00)00441-7"},{"key":"e_1_3_1_24_1","doi-asserted-by":"crossref","unstructured":"23. Ellis MF. Sharp -edged intraocular lens design as a cause of permanent glare. \/ Cataract Refract Surg. 2001;27:1061-1064.","DOI":"10.1016\/S0886-3350(00)00856-7"},{"key":"e_1_3_1_25_1","doi-asserted-by":"crossref","unstructured":"24. Casprini F Tosi GM Quercioli PP Caporossi A. Comparison of AcrySof MA30BA and Sensar AR40 acrylic intraocular lenses. \/ Cataract Refract Surg. 2002;28:1130-1134.","DOI":"10.1016\/S0886-3350(02)01427-X"},{"key":"e_1_3_1_26_1","doi-asserted-by":"crossref","unstructured":"25. Alessio G Cardasela N Sborgia C. Visual discomfort after acrylic intraocular lens implantation. \/ Cataract Refract Surg. 2002;28:1293-1295.","DOI":"10.1016\/S0886-3350(01)01309-8"},{"key":"e_1_3_1_27_1","doi-asserted-by":"crossref","unstructured":"26. Erie JC Bandhauer MH McLaren JW. Analysis of postoperative glare and intraocular lens design. \/ Cataract Refract Surg. 2001;27:614-621.","DOI":"10.1016\/S0886-3350(00)00781-1"},{"key":"e_1_3_1_28_1","doi-asserted-by":"crossref","unstructured":"27. Erie JC Bandhauer MH. Intraocular lens surface and their relationship to postoperative glare. \/ Cataract Refract Surg. 2003;29:336-341.","DOI":"10.1016\/S0886-3350(02)01442-6"},{"key":"e_1_3_1_29_1","doi-asserted-by":"crossref","unstructured":"28. Nishihara H Yaguchi S Onishi T Chida M Ayaki M. Surface scattering in implanted hydrophobic intraocular lenses. \/ Cataract Refract Surg. 2003;29:1385-1388.","DOI":"10.1016\/S0886-3350(02)01994-6"},{"key":"e_1_3_1_30_1","doi-asserted-by":"crossref","unstructured":"29. Masket S. Truncated edge design dysphotopsia and inhibition of posterior capsule opacification. \/ Cataract Refract Surg. 2000;26:145-147.","DOI":"10.1016\/S0886-3350(99)00329-6"},{"key":"e_1_3_1_31_1","doi-asserted-by":"crossref","unstructured":"30. Holladay JT Lang A Portney V. Analysis of edge glare phenomena in intraocular lens edge designs. \/ Cataract Refract Surg. 1999;25:748-752.","DOI":"10.1016\/S0886-3350(99)00038-3"},{"key":"e_1_3_1_32_1","doi-asserted-by":"crossref","unstructured":"31. Escobar-Gomez M Apple DJ Vargas LG Werner L Arthur SN Pandey SK Izak AM Schmidbauer JM. Scanning electron microscopic and histologic evaluation of the AcrySof S A3 OAL acrylic intraocular lens. Manufacturing quality and morphology in the capsillar bag . \/ Cataract Refract Surg. 2003;29:164-169.","DOI":"10.1016\/S0886-3350(02)01435-9"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T10:06:23Z","timestamp":1683108383000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081-597X-20051101-10"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2005,11]]}},"alternative-id":["10.3928\/1081-597X-20051101-10"],"URL":"https:\/\/doi.org\/10.3928\/1081-597x-20051101-10","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2005,11]]}}}