{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T17:02:23Z","timestamp":1791219743205,"version":"4.1.0"},"reference-count":27,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2007,11]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess visual, optical, and fitting characteristics for wavefront-guided soft contact lenses produced for one habitual soft lens-wearing moderate keratoconic eye.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A process for production and evaluation of custom wavefront-guided soft contact lenses was developed. Wavefront aberrations were quantified with the COAS-HD wavefront sensor (Wavefront Sciences); soft contact lenses containing both high and low order aberrations were designed with custom software and produced using an ophthalmic lens lathe. Photopic high and low contrast logMAR visual acuity were recorded with the lens in place over an artificial 5-mm pupil and residual 2nd to 10th order root-mean-square (RMS) aberrations were analyzed over a 5-mm pupil. Comparisons were made to the eye's habitual toric soft contact lens using\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      tests.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Photopic high contrast values for habitual and final custom contact lenses for a 5-mm pupil were 0.07\u00b10.06 and \u22120.08\u00b10.05, respectively. Photopic low contrast values were 0.73\u00b10.06 and 0.62\u00b10.07, respectively. Habitual and final custom correction low order RMS over a 5-mm pupil were 2.08 and 0.34 \u00b5m, and high order RMS levels were 0.77 and 0.39 \u00b5m, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>\n                      The final custom contact lens showed 1.5 lines of improvement for photopic high contrast (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =.03) and 1 line for photopic low contrast (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =.11) over a 5-mm pupil compared to habitual correction. Low and high order aberrations were reduced by 84% and 50% over a 5-mm pupil, respectively. Further improvements in performance of custom lenses may be achieved with further wavefront iterations. [\n                      <jats:italic toggle=\"yes\">J Refract Surg.<\/jats:italic>\n                      2007;23:960\u2013964.]\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081-597x-20071101-18","type":"journal-article","created":{"date-parts":[[2019,1,2]],"date-time":"2019-01-02T10:58:54Z","timestamp":1546426734000},"page":"960-964","source":"Crossref","is-referenced-by-count":48,"title":["On-eye Performance of Custom Wavefront-guided Soft Contact Lenses in a Habitual Soft Lens-wearing Keratoconic Patient"],"prefix":"10.3928","volume":"23","author":[{"given":"Jason D.","family":"Marsack","sequence":"first","affiliation":[{"name":"Visual Optics Institute, College of Optometry, University of Houston, Houston, Tex"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katrina E.","family":"Parker","sequence":"additional","affiliation":[{"name":"Visual Optics Institute, College of Optometry, University of Houston, Houston, Tex"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yafei","family":"Niu","sequence":"additional","affiliation":[{"name":"Visual Optics Institute, College of Optometry, University of Houston, Houston, Tex"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konrad","family":"Pesudovs","sequence":"additional","affiliation":[{"name":"The NH&amp;MRC Centre for Clinical Eye Research, Department of Ophthalmology, Flinders Medical Centre and Flinders University, Bedford Park, South Australia, Australia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raymond A.","family":"Applegate","sequence":"additional","affiliation":[{"name":"Visual Optics Institute, College of Optometry, University of Houston, Houston, Tex"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0039-6257(84)90094-8"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(97)00119-7"},{"key":"e_1_3_2_4_2","unstructured":"Pantanelli S Yoon G Jeong TM MacRae S. Aberration characterization of abnormal eyes using the large dynamic range Shack-Hartmann wavefront sensor. Invest Ophthalmol Vis Sci. 2004;45:E-Abstract 2848."},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01279-4"},{"key":"e_1_3_2_6_2","first-page":"2537","article-title":"Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study","volume":"39","author":"Zadnik K","year":"1998","unstructured":"Zadnik K, Barr JT, Edrington TB, Everett DF, Jameson M, McMahon TT, Shin JA, Sterling JL, Wagner H, Gordon MO. Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. Invest Ophthalmol Vis Sci. 1998;39:2537\u20132546.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199503000-00006"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e31802e64f0"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.18.001003"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.000126"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200309000-00008"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00140068-200301001-00046"},{"key":"e_1_3_2_13_2","first-page":"471","article-title":"Applying wavefront sensors and corneal topography to keratoconus","volume":"38","author":"Marsack J","year":"2002","unstructured":"Marsack J, Milner T, Rylander G, Leach N, Roorda A. Applying wavefront sensors and corneal topography to keratoconus. Biomed Sci Instrum. 2002;38:471\u2013476.","journal-title":"Biomed Sci Instrum"},{"key":"e_1_3_2_14_2","first-page":"25","article-title":"Seeing into the future with contact lenses","volume":"2","author":"Kollbaum P","year":"2003","unstructured":"Kollbaum P. Seeing into the future with contact lenses. Contact Lens Spectrum. 2003;2:25\u201329.","journal-title":"Contact Lens Spectrum"},{"key":"e_1_3_2_15_2","first-page":"279","volume-title":"Wavefront Customized Visual Correction: The Quest for Super Vision","author":"Cox IG","year":"2004","unstructured":"Cox IG, Lagana M. Feasibility of wavefront customized contact lenses. In: Krueger R, Applegate R, MacRae S, eds. Wavefront Customized Visual Correction: The Quest for Super Vision. 2nd ed. Thorofare, NJ: SLACK Incorporated; 2004:279\u2013284.","edition":"2"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.000620"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.23.000769"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-25"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-1222"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.05.025"},{"key":"e_1_3_2_21_2","article-title":"Can the Zernike polynomials reliably represent the aberration in normal and abnormal eyes?","volume":"47","author":"Pantanelli SM","year":"2006","unstructured":"Pantanelli SM, Yoon GY. Can the Zernike polynomials reliably represent the aberration in normal and abnormal eyes? Invest Ophthalmol Vis Sci. 2006;47:E-Abstract 1204.","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-22"},{"key":"e_1_3_2_23_2","article-title":"Correcting higher order aberrations using customized soft contact lenses in keratoconic eyes","volume":"47","author":"Sabesan R","year":"2006","unstructured":"Sabesan R, Carvalho L, Jeong T, Yoon GY, Somasundaram R, Cox IG. Correcting higher order aberrations using customized soft contact lenses in keratoconic eyes. Invest Ophthalmol Vis Sci. 2006;47:E-Abstract 1205.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20040901-20"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-12"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200302000-00005"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00334-1"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.24.000578"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T15:46:21Z","timestamp":1765813581000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081-597X-20071101-18"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,11]]},"references-count":27,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2007,11]]}},"alternative-id":["10.3928\/1081-597X-20071101-18"],"URL":"https:\/\/doi.org\/10.3928\/1081-597x-20071101-18","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2007,11]]}}}