{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T16:26:22Z","timestamp":1761841582004},"reference-count":21,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2008,3]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To compare the visual outcomes of two intraocular lenses (IOLs) (Acri.Smart [multifocal] and AT-45 [accommodative]) for correction of distance and near visual acuity with a LASIK procedure for presbyopia (presbyLASIK) and a control group fitted with a standard distance-correcting monofocal IOL (Acrysof).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Distance and near decimal visual acuities were measured under similar conditions before and 6 months postoperatively in 45 patients (87 eyes) who comprised four groups: Acri.Smart IOL, AT-45 IOL, presby-LASIK, and control (monofocal IOL). All acuity measures were standardized at 20 m (distance, projected chart) and 40 cm (near). All visual acuity measures were taken in the same ambient light conditions and contrast. All data were collected in a randomized, masked style.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Pre- and postoperative distance mean visual acuities for the Acri.Smart IOL, AT-45 IOL, presbyLASIK, and controls groups, respectively, were 0.15\u00b10.21 and 0.66\u00b10.35; 0.31\u00b10.14 and 0.68\u00b10.28; 0.35\u00b10.15 and 0.80\u00b10.33; and 0.32\u00b10.18 and 0.59\u00b10.29. Pre- and postoperative near mean visual acuities for the Acri.Smart IOL, AT-45 IOL, presbyLASIK, and control groups, respectively, were 0.13\u00b10.21 and 0.62\u00b10.35; 0.43\u00b10.22 and 0.51\u00b10.27; 0.15\u00b10.20 and 0.68\u00b10.33; and 0.40\u00b10.29 and 0.30\u00b10.13. Distance and near visual acuities improved significantly after surgery (\n              <jats:italic>P<\/jats:italic>\n              &lt;.05) except near acuities for the AT-45 IOL and control groups.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>\n              For these patients, distance and near acuities improved with presbyLASIK and Acri.Smart IOLs when compared with controls. In those patients treated with the AT-45 IOL, average distance visual acuity improved but not near visual acuity. [\n              <jats:italic>J Refract Surg<\/jats:italic>\n              . 2008;24:294\u2013299.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20080301-12","type":"journal-article","created":{"date-parts":[[2019,2,7]],"date-time":"2019-02-07T18:36:38Z","timestamp":1549564598000},"page":"294-299","source":"Crossref","is-referenced-by-count":36,"title":["Comparison of Acri.Smart Multifocal IOL, Crystalens AT-45 Accommodative IOL, and Technovision PresbyLASIK for Correcting Presbyopia"],"prefix":"10.3928","volume":"24","author":[{"given":"Sudi","family":"Patel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorge L.","family":"Ali\u00f3","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claes","family":"Feinbaum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"doi-asserted-by":"publisher","key":"e_1_3_1_2_2","DOI":"10.1001\/archopht.1992.01080190100036"},{"doi-asserted-by":"publisher","key":"e_1_3_1_3_2","DOI":"10.1097\/00004397-199403440-00010"},{"doi-asserted-by":"publisher","key":"e_1_3_1_4_2","DOI":"10.3928\/1081-597X-19980401-18"},{"key":"e_1_3_1_5_2","first-page":"1","article-title":"Controlled multizone LASIK with concentric peripheral near zone for presbyopia treatment","volume":"2","author":"El Danasoury MA","year":"2004","unstructured":"El Danasoury MA. Controlled multizone LASIK with concentric peripheral near zone for presbyopia treatment. Refractive Express. 2004;2:1\u20136.","journal-title":"Refractive Express"},{"key":"e_1_3_1_6_2","first-page":"50","article-title":"Correcting presbyopia at present: scleral expansion and IOL implantation appear to hold the most promise","volume":"1","author":"Lovisolo C","year":"2004","unstructured":"Lovisolo C. Correcting presbyopia at present: scleral expansion and IOL implantation appear to hold the most promise. Cataract & Refractive Surgery Today. 2004;1:50\u201352.","journal-title":"Cataract & Refractive Surgery Today"},{"key":"e_1_3_1_7_2","first-page":"63","article-title":"Corneal-based presbyopia surgery: preliminary results of corneal multifocal ablation for treating presbyopia","volume":"1","author":"Herzig S","year":"2004","unstructured":"Herzig S. Corneal-based presbyopia surgery: preliminary results of corneal multifocal ablation for treating presbyopia. Cataract & Refractive Surgery Today. 2004;1:63\u201366.","journal-title":"Cataract & Refractive Surgery Today"},{"doi-asserted-by":"publisher","key":"e_1_3_1_8_2","DOI":"10.1097\/00006324-200109000-00009"},{"doi-asserted-by":"publisher","key":"e_1_3_1_9_2","DOI":"10.1111\/j.1475-1313.1989.tb00831.x"},{"key":"e_1_3_1_10_2","first-page":"1132","article-title":"Factors affecting light-adapted pupil size in normal human subjects","volume":"35","author":"Winn B","year":"1994","unstructured":"Winn B, Whitaker D, Elliott DB, Phillips NJ. Factors affecting light-adapted pupil size in normal human subjects. Invest Ophthalmol Vis Sci. 1994;35:1132\u20131137.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_1_11_2","first-page":"59","article-title":"Aberrations of the eye and their effects on vision, 1, spherical aberration","volume":"20","author":"Jenkins TC","year":"1963","unstructured":"Jenkins TC. Aberrations of the eye and their effects on vision, 1, spherical aberration. Br J Physiol Opt. 1963;20:59\u201391.","journal-title":"Br J Physiol Opt"},{"doi-asserted-by":"publisher","key":"e_1_3_1_12_2","DOI":"10.1364\/JOSAA.10.001656"},{"doi-asserted-by":"publisher","key":"e_1_3_1_13_2","DOI":"10.1364\/JOSAA.4.000851"},{"doi-asserted-by":"publisher","key":"e_1_3_1_14_2","DOI":"10.1016\/j.jcrs.2003.07.007"},{"doi-asserted-by":"publisher","key":"e_1_3_1_15_2","DOI":"10.1016\/j.jcrs.2003.07.008"},{"doi-asserted-by":"publisher","key":"e_1_3_1_16_2","DOI":"10.3928\/1081-597X-20060501-06"},{"doi-asserted-by":"publisher","key":"e_1_3_1_17_2","DOI":"10.3928\/1081-597X-20070101-07"},{"doi-asserted-by":"publisher","key":"e_1_3_1_18_2","DOI":"10.1016\/j.jcrs.2004.04.052"},{"doi-asserted-by":"publisher","key":"e_1_3_1_19_2","DOI":"10.1016\/j.ophtha.2005.04.033"},{"doi-asserted-by":"publisher","key":"e_1_3_1_20_2","DOI":"10.1016\/S0161-6420(01)00779-5"},{"doi-asserted-by":"publisher","key":"e_1_3_1_21_2","DOI":"10.1001\/archopht.121.12.1722"},{"doi-asserted-by":"publisher","key":"e_1_3_1_22_2","DOI":"10.1159\/000086169"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/ophthalmology\/refractive-surgery\/journals\/jrs\/2008-3-24-3\/%7Ba6342930-d58b-47ff-9f93-c27c13fea94a%7D\/comparison-of-acrismart-multifocal-iol-crystalens-at-45-accommodative-iol-and-technovision-presbylasik-for-correcting-presbyopia","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,24]],"date-time":"2024-09-24T18:16:28Z","timestamp":1727201788000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20080301-12"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,3]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,3]]}},"alternative-id":["10.3928\/1081597X-20080301-12"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20080301-12","relation":{},"ISSN":["1081-597X"],"issn-type":[{"type":"print","value":"1081-597X"}],"subject":[],"published":{"date-parts":[[2008,3]]}}}