{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:51:49Z","timestamp":1790297509795,"version":"4.1.0"},"reference-count":27,"publisher":"SLACK, Inc.","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2008,10]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>To compare treatments with wavefront optimized and custom-Q ablations.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Two consecutive groups of eyes were treated for myopia and astigmatism with surface ablation. One group was treated with wavefront optimized ablation and the second group was treated with custom-Q ablation. Preoperative and 3-month postoperative Q-values, higher order aberrations, low contrast visual acuity, and classic outcome parameters were analyzed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              The wavefront optimized ablation group was comprised of 46 eyes of 23 patients with a mean spherical equivalent refraction (SE) of \u22123.64 diopters (D) (range: \u22121.15 to \u22128.25 D); mean Q-value changed from \u22120.33 preoperatively to 0.06 postoperatively. The custom-Q ablation group was comprised of 42 eyes of 21 patients with a mean SE of \u22123.24 D (range: \u22121.47 to \u22128.00 D); mean Q-value changed from \u22120.36 preoperatively to \u22120.03 postoperatively. A statistically significant difference in postoperative change in Q-values (\n              <jats:italic>P<\/jats:italic>\n              =.049) between the two groups was noted, but there was no such difference in higher order aberrations, low contrast visual acuity, or classic outcome parameters.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>\n              Custom-Q ablation resulted in a mean postoperative asphericity that was closer to preoperative compared to wavefront optimized ablation, whereas the other outcome parameters showed no statistically significant differences. [\n              <jats:italic>J Refract Surg.<\/jats:italic>\n              2008;24:779\u2013789.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20081001-03","type":"journal-article","created":{"date-parts":[[2019,9,25]],"date-time":"2019-09-25T20:29:28Z","timestamp":1569443368000},"page":"779-789","source":"Crossref","is-referenced-by-count":32,"title":["Wavefront Optimized Versus Custom-Q Treatments in Surface Ablation for Myopic Astigmatism With the WaveLight ALLEGRETTO Laser"],"prefix":"10.3928","volume":"24","author":[{"given":"Aleksandar","family":"Stojanovic","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirko R.","family":"Jankov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tore A.","family":"Nitter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qinmei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(91)32157-2"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(98)00288-8"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000701-03"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020101-03"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01895-3"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030901-17"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.049"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.11.026"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00742-2"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030501-11"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01638-3"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20051101-25"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19980401-12"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000232227.70122.b5"},{"key":"e_1_3_1_16_2","first-page":"11","volume-title":"Optics of the Human Eye","author":"Atchinson D","year":"2003","unstructured":"Atchinson D, Smith G. Refractive components: cornea and lens. In: Atchinson D, Smith G, eds. Optics of the Human Eye. Edinburgh, United Kingdom: Butterworth-Heinemann; 2003:11\u201320."},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010901-15"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20030701-11"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-18"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.01.026"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.01.051"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2004.01.005"},{"key":"e_1_3_1_23_2","first-page":"77","article-title":"Minimizing postoperative discomfort","author":"Trottler WB","year":"2007","unstructured":"Trottler WB. Minimizing postoperative discomfort. Cataract & Refractive Surgery Today. January 2007:77\u201378.","journal-title":"Cataract & Refractive Surgery Today"},{"key":"e_1_3_1_24_2","first-page":"1","article-title":"Epi-LASIK: A round table discussion","author":"Pallikaris I","year":"2005","unstructured":"Pallikaris I, McDonald M, Cross W, Durrie D, Camellin M, Vinciguerra P, Katsanevski V, Volpicelli, M, Kantor R. Epi-LASIK: A round table discussion. Supplement to Cataract & Refractive Surgery Today. May 2005:1\u201311.","journal-title":"Supplement to Cataract & Refractive Surgery Today"},{"key":"e_1_3_1_25_2","first-page":"941","article-title":"Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity","volume":"43","author":"Gatinel D","year":"2002","unstructured":"Gatinel D, Malet J, Hoang-Xuan T, Azar DT. Analysis of customized corneal ablations: theoretical limitations of increasing negative asphericity. Invest Ophthalmol Vis Sci. 2002;43:941\u2013948.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20061001-04"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060901-04"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20061101-25"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/ophthalmology\/refractive-surgery\/journals\/jrs\/2008-10-24-8\/%7B7dd0b966-3fd6-451f-a8aa-16d83a38cc2e%7D\/wavefront-optimized-versus-custom-q-treatments-in-surface-ablation-for-myopic-astigmatism-with-the-wavelight-allegretto-laser","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,15]],"date-time":"2024-11-15T18:42:14Z","timestamp":1731696134000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20081001-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,10]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2008,10]]}},"alternative-id":["10.3928\/1081597X-20081001-03"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20081001-03","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2008,10]]}}}