{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T05:32:20Z","timestamp":1780551140144,"version":"3.54.1"},"reference-count":20,"publisher":"SLACK, Inc.","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2009,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To determine whether use of Corneal Refractive Therapy (CRT\u00ae, Paragon Vision Sciences) lenses have an adverse effect on the health of corneal epithelium by monitoring epithelial permeability by fluorophotometry.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Eight patients with healthy eyes and whose refractive error was between \u22120.50 and \u22124.00 diopters (D) sphere and up to \u22121.75 D of astigmatism were enrolled. On the day of the fitting, two baseline fluorometric scans of the right eye were taken using the Ocumetrics Fluorotron Master. After 15 minutes, another two scans were taken of the right eye. The same fluorophotometry technique was repeated on day 1, 1 week, 1 month, and 3 months after the patient began overnight wear of the lenses. Patients' baseline corneal fluorescein levels and peak corneal fluorescence values after rinsing were compared to initial pre-fitting values to determine changes in corneal epithelial permeability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              After patients used orthokeratology, uncorrected visual acuity was 20\/20 or better in 9\/16 eyes and 100% had achieved 20\/40 or better by day 7. No adverse events were seen in patients utilizing orthokeratology, and eye examinations for these patients continued to be within normal limits. After nightly use of orthokeratology for 1 month, baseline fluorescence of the cornea (15.64\u00b12.29 ng\/mL vs 17.31\u00b15.43 ng\/mL,\n              <jats:italic>P<\/jats:italic>\n              =.80) remained stable, and the post-15 minute scan peak corneal fluorescence values did not show significant changes from the pre-fitting (51.46\u00b117.28 ng\/mL) after use of orthokeratology (63.80\u00b141.25 ng\/mL)(\n              <jats:italic>P<\/jats:italic>\n              =.78).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>\n              Reshaping of the cornea through the use of orthokeratology does not have adverse effects on corneal epithelium as evaluated by changes in corneal epithelial permeability. [\n              <jats:italic>J Refract Surg<\/jats:italic>\n              . 2009;25:366\u2013370.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20090401-12","type":"journal-article","created":{"date-parts":[[2009,12,14]],"date-time":"2009-12-14T20:56:35Z","timestamp":1260824195000},"page":"366-370","source":"Crossref","is-referenced-by-count":11,"title":["Fluorophotometry to Evaluate the Corneal Epithelium in Eyes Undergoing Contact Lens Corneal Reshaping to Correct Myopia"],"prefix":"10.3928","volume":"25","author":[{"given":"Danielle Z.","family":"Savitsky","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent C.","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elvin H.","family":"Yildiz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ted T.","family":"Du","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Penny A.","family":"Asbell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199811000-00019"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000140234.85617.88"},{"key":"e_1_3_2_4_2","article-title":"Cornea reshaping: combining two methods of correcting myopia","author":"Eiden SB","year":"2002","unstructured":"Eiden SB, Dawson A. Cornea reshaping: combining two methods of correcting myopia. Contact Lens Spectrum. December, 2002.","journal-title":"Contact Lens Spectrum"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000140224.70483.2F"},{"key":"e_1_3_2_6_2","first-page":"5","volume-title":"Paragon CRT FDA Professional Fitting and Information Booklet","year":"2002","unstructured":"Paragon CRT FDA Professional Fitting and Information Booklet. Mesa, Ariz: Paragon Vision Sciences; 2002:5."},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.icl.0000179709.76832.4f"},{"key":"e_1_3_2_8_2","first-page":"47","article-title":"Orthokeratology: an update","volume":"7","author":"van der Worp E","year":"2006","unstructured":"van der Worp E, Ruston D. Orthokeratology: an update. Optometry in Practice. 2006;7:47\u201360.","journal-title":"Optometry in Practice"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000140230.56008.EF"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.icl.0000179705.23313.7e"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000072831.13880.A0"},{"key":"e_1_3_2_12_2","first-page":"1019","article-title":"Impact of rigid gas-permeable contact lens extended wear on corneal epithelial barrier function","volume":"43","author":"Lin MC","year":"2002","unstructured":"Lin MC, Graham AD, Fusaro RE, Polse KA. Impact of rigid gas-permeable contact lens extended wear on corneal epithelial barrier function. Invest Ophthalmol Vis Sci. 2002;43:1019\u20131024.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000140235.11667.B0"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318042af1d"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2415-6-20"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.82.4.376"},{"key":"e_1_3_2_17_2","first-page":"1681","article-title":"Ascorbic acid content of human corneal epithelium","volume":"41","author":"Brubaker RF","year":"2000","unstructured":"Brubaker RF, Bourne WM, Bachman LA, McLaren JW. Ascorbic acid content of human corneal epithelium. Invest Ophthalmol Vis Sci. 2000;41:1681\u20131683.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/0014-4835(75)90150-5"},{"key":"e_1_3_2_19_2","article-title":"Simplified technique of fluorophotometry for corneal permeability evaluation in humans","volume":"48","author":"Fan VC","year":"2007","unstructured":"Fan VC, Koonapareddy CV, Chen D, Du TT, Asbell PA. Simplified technique of fluorophotometry for corneal permeability evaluation in humans. Invest Ophthalmol Vis Sci. 2007;48:EAbstract 803.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_20_2","first-page":"1830","article-title":"Measurement of corneal epithelial permeability to fluorescein. A repeatability study","volume":"38","author":"McNamara NA","year":"1997","unstructured":"McNamara NA, Fusaro RE, Brand RJ, Polse KA, Srinivas SP. Measurement of corneal epithelial permeability to fluorescein. A repeatability study. Invest Ophthalmol Vis Sci. 1997;38:1830\u20131839.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200209000-00011"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20090401-12","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T15:53:41Z","timestamp":1683042821000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20090401-12"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4]]},"references-count":20,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2009,4]]}},"alternative-id":["10.3928\/1081597X-20090401-12"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20090401-12","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,4]]}}}