{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T13:24:38Z","timestamp":1788269078131,"version":"build-2803163510"},"reference-count":35,"publisher":"SLACK, Inc.","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2009,7]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To determine the 1-year stability of LASIK in corneas with topographic suspect keratoconus confirmed as non-keratoconic by epithelial thickness mapping.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This was a retrospective case\/control comparative study. Eyes suspected of keratoconus using criteria based mainly on Atlas (Carl Zeiss Meditec AG) and Orbscan II (Bausch &amp; Lomb) topography were scanned by Artemis very high-frequency digital ultrasound (ArcScan Inc). Keratoconus was confirmed if the epithelial thickness profile showed relative epithelial thinning coincident with an eccentric posterior elevation best-fit sphere apex. Laser in situ keratomileusis was performed in all eyes where keratoconus was excluded by finding relatively thicker epithelium or not finding localized thinning over the topographically suspected cone. Patients were followed for 1 year after LASIK. A control group was generated matched within 0.50 diopter (D) for sphere, cylinder, and spherical equivalent refraction (SEQ) to compare refractive stability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The average change in SEQ between 3 and 12 months was \u22120.10\u00b10.30 D for the suspect keratoconus group and \u22120.10\u00b10.28 D for controls. No statistically significant difference in shift from 3 months to 12 months in SEQ or cylinder between groups was noted. No statistically significant change in best spectacle-corrected visual acuity between groups was noted, with no eye losing 2 lines and 5% in the suspect keratoconus group and 2% of controls losing 1 line. No cases of ectasia were observed in either group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>\n              Suspect keratoconus, confirmed to be non-keratoconic by epithelial thickness profile criteria demonstrated equal stability to control eyes 1 year after LASIK. Epithelial thickness profiles may enable LASIK to be performed in eyes that would otherwise have been excluded due to topographic suspect keratoconus. Further follow-up is being carried out. [\n              <jats:italic>J Refract Surg.<\/jats:italic>\n              2009;25:569\u2013577.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20090610-02","type":"journal-article","created":{"date-parts":[[2018,12,23]],"date-time":"2018-12-23T22:19:58Z","timestamp":1545603598000},"page":"569-577","source":"Crossref","is-referenced-by-count":58,"title":["Stability of LASIK in Topographically Suspect Keratoconus Confirmed Non-keratoconic by Artemis VHF Digital Ultrasound Epithelial Thickness Mapping: 1-year Follow-up"],"prefix":"10.3928","volume":"25","author":[{"given":"Dan Z.","family":"Reinstein","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy J.","family":"Archer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marine","family":"Gobbe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","volume-title":"Queratomileusis y queratofakia","author":"Barraquer JI","year":"1980","unstructured":"Barraquer JI. Queratomileusis y queratofakia. Bogota, Colombia: Instituto Barraquer de America; 1980."},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80057-6"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.12.033"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.03.073"},{"key":"e_1_3_2_6_2","first-page":"282","article-title":"Iatrogenic keratoconus: corneal ectasia following laser in situ keratomileusis for myopia","volume":"118","author":"McLeod SD","year":"2000","unstructured":"McLeod SD, Kisla TA, Caro NC, McMahon TT. Iatrogenic keratoconus: corneal ectasia following laser in situ keratomileusis for myopia. Arch Ophthalmol. 2000;118:282\u2013284.","journal-title":"Arch Ophthalmol"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000501-12"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00805-1"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)00799-4"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.119.11.1714"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01727-X"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ICL.0000060780.24132.51"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00047-6"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00284-9"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19950901-14"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00195-9"},{"key":"e_1_3_2_17_2","first-page":"2749","article-title":"Automated keratoconus screening with corneal topography analysis","volume":"35","author":"Maeda N","year":"1994","unstructured":"Maeda N, Klyce SD, Smolek MK, Thompson HW. Automated keratoconus screening with corneal topography analysis. Invest Ophthalmol Vis Sci. 1994;35:2749\u20132757.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090610-06"},{"key":"e_1_3_2_19_2","volume-title":"Ultrasonography of the Eye and Orbit","author":"Reinstein DZ","year":"2005","unstructured":"Reinstein DZ, Silverman RH, Rondeau MJ, Lloyd HO, Lizzi FL, Daley SW, Coleman DJ. Very high frequency digital ultrasound scanning in LASIK and phakic intraocular lenses. In: Coleman DJ, Silverman RH, Lizzi FL, eds. Ultrasonography of the Eye and Orbit. 2nd ed. Philadelphia, Pa: Lippincott Williams & Wilkins; 2005.","edition":"2"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.07.016"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.1.25"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6700652"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.044"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-0694"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.06.025"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(94)31314-5"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20000701-04"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060501-03"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080601-05"},{"key":"e_1_3_2_30_2","doi-asserted-by":"crossref","unstructured":"Reinstein D Archer T Gobbe M Silverman R Coleman DJ. Stromal thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasound. J Refract Surg . Available at http:\/\/www.journalofrefractivesurgery.com\/preprint.asp. Posted online September 30 2008.","DOI":"10.3928\/1081597X-20090813-04"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060101-16"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.icu.0000233963.26628.f0"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20050901-12"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01914-4"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080901-11"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080201-04"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T13:53:19Z","timestamp":1683035599000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20090610-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,7]]},"references-count":35,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2009,7]]}},"alternative-id":["10.3928\/1081597X-20090610-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20090610-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,7]]}}}