{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T18:19:40Z","timestamp":1782497980093,"version":"3.54.5"},"reference-count":31,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2010,5]]},"abstract":"<jats:sec>\n            <jats:title>PURPOSE:<\/jats:title>\n            <jats:p>The accuracy of intraocular lens (IOL) calculation is limited by the variation of the measurement of corneal power, axial length, anterior chamber depth, and effective postoperative lens position. Therefore, IOL predictability is limited. The aim of this study was to evaluate the performance of the novel light adjustable lens (LAL, Calhoun Vision).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS:<\/jats:title>\n            <jats:p>Ten eyes with cataracts (seven patients) were included. After standard phacoemulsification, the LAL was implanted. Two to 3 weeks after surgery, all IOL adjustments had been completed. Preoperatively, pre-adjustment, pre-lock-in, and 1 month post-lock-in, a full ophthalmic examination including objective (autorefraction) and subjective refraction (ie, manifest uncorrected visual acuity [UCVA] and manifest best spectacle-corrected visual acuity [BSCVA]) and topography were performed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>All cataract surgeries were performed with no complications. Two weeks after surgery, the mean refraction was +0.78\u00b10.79 diopters (D). After adjustment and lock-in, the refraction was \u22120.07\u00b10.21 D. In 4 of 10 eyes, second adjustments were necessary. One month after surgery, all patients were within \u00b10.50 D of the intended refraction. Preoperatively, the cylinder was 0.88\u00b10.77 D, but was reduced after adjustments to 0.15\u00b10.20 D. Mean UCVA was 1.02, and all eyes gained at least two lines on the Snellen visual acuity test (ie, BSCVA) after surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>\n              The LAL is a new IOL with the ability to correct up to 2.00 D of sphere and cylinder after implantation. Our first clinical results are promising and indicate effective safety and stability. [\n              <jats:italic>J Refract Surg<\/jats:italic>\n              . 2010;26:314\u2013320.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20090617-12","type":"journal-article","created":{"date-parts":[[2010,5,27]],"date-time":"2010-05-27T19:40:22Z","timestamp":1274989222000},"page":"314-320","source":"Crossref","is-referenced-by-count":14,"title":["Clinical Results With the Light Adjustable Intraocular Lens After Cataract Surgery"],"prefix":"10.3928","volume":"26","author":[{"given":"Christoph Winkler","family":"von Mohrenfels","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josefina","family":"Salgado","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramin","family":"Khoramnia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathias","family":"Maier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris P.","family":"Lohmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)00505-9"},{"key":"e_1_3_2_3_2","first-page":"158","article-title":"Minimizing induction of astigmatism in preoperative spherical cornea a. by mini-incision surgery with foldable IOL and b. by corneal tunnel incision with limbal relaxing incision [German]","volume":"215","author":"M\u00fcller-Jensen K","year":"1999","unstructured":"M\u00fcller-Jensen K, Fischer P. Minimizing induction of astigmatism in preoperative spherical cornea a. by mini-incision surgery with foldable IOL and b. by corneal tunnel incision with limbal relaxing incision [German]. Klin Monatsbl Augenheilkd. 1999;215:158\u2013162.","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00379-1"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-008-1744-9"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200502000-00004"},{"key":"e_1_3_2_7_2","first-page":"89","article-title":"Multifocal intraocular lenses","volume":"19","author":"Lane SS","year":"2006","unstructured":"Lane SS, Morris M, Nordan L, Packer M, Tarantino N, Wallace RB III. Multifocal intraocular lenses. Ophthalmol Clin North Am. 2006;19:89\u2013105, vi.","journal-title":"Ophthalmol Clin North Am"},{"issue":"4","key":"e_1_3_2_8_2","first-page":"CD003169","article-title":"Multifocal versus monofocal intraocular lenses after cataract extraction","author":"Leyland M","year":"2006","unstructured":"Leyland M, Pringle E. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2006;4:CD003169.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.03.061"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.07.033"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070201-08"},{"key":"e_1_3_2_12_2","first-page":"893","article-title":"Accuracy limits in IOL calculation: current status [German]","volume":"224","author":"Preussner PR","year":"2007","unstructured":"Preussner PR. Accuracy limits in IOL calculation: current status [German]. Klin Monatsbl Augenheilkd. 2007;224:893\u2013899.","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2007.00879.x"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e3282f1c5ad"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200502000-00011"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-008-1828-6"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702300"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2007.10.012"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80103-X"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.09.009"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.01.015"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.10.017"},{"key":"e_1_3_2_23_2","first-page":"29","article-title":"Light-adjustable lens: customizing correction for multifocality and higher-order aberrations","volume":"104","author":"Sandstedt CA","year":"2006","unstructured":"Sandstedt CA, Chang SH, Grubbs RH, Schwartz DM. Light-adjustable lens: customizing correction for multifocality and higher-order aberrations. Trans Am Ophthalmol Soc. 2006;104:29\u201339.","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_3_2_24_2","first-page":"417","article-title":"Light-adjustable lens","volume":"101","author":"Schwartz DM","year":"2003","unstructured":"Schwartz DM. Light-adjustable lens. Trans Am Ophthalmol Soc. 2003;101:417\u2013436.","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_3_2_25_2","first-page":"67","article-title":"Light-adjustable lens: development of in vitro nomograms","volume":"102","author":"Schwartz DM","year":"2004","unstructured":"Schwartz DM, Sandstedt CA, Chang SH, Kornfield JA, Grubbs RH. Light-adjustable lens: development of in vitro nomograms. Trans Am Ophthalmol Soc. 2004;102:67\u201372.","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_3_2_26_2","volume-title":"Chemistry & Technology of UV & EB Formulation for Coatings, Inks & Paints","author":"Crivello JV","year":"1999","unstructured":"Crivello JV, Dietliker K. Photoinitiators for free radical cationic & anionic photopolymerization. In: Bradley G, ed. Chemistry & Technology of UV & EB Formulation for Coatings, Inks & Paints. 2nd ed. Vol 3. London, United Kingdom: John Wiley & Sons; 1999.","edition":"2"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(86)90400-9"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-006-1398-4"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90504-3"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80232-5"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00266-9"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01035-5"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20090617-12","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,2]],"date-time":"2023-05-02T22:35:45Z","timestamp":1683066945000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20090617-12"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,5]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2010,5]]}},"alternative-id":["10.3928\/1081597X-20090617-12"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20090617-12","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2010,5]]}}}