{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T17:52:01Z","timestamp":1783619521097,"version":"3.55.0"},"reference-count":15,"publisher":"SLACK, Inc.","issue":"S4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2009,10]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To assess axis alignment and stability of the Toric Implantable Collamer Lens (TICL; STAAR Surgical Co) over time.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Thirty-five consecutive eyes of 19 patients received the TICL for treatment of myopic astigmatism. Manifest refraction spherical equivalent (MRSE) and manifest refractive cylinder were measured preoperatively and at 3 months postoperatively. The axis alignment of the TICL was measured using the internal OPD map obtained with the OPD-Scan II (NIDEK Co Ltd).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Mean refractive cylinder was reduced from 2.80\u00b11.45 diopters (D) preoperatively to 0.63\u00b10.75 D at 3 months postoperatively; MRSE was \u22127.61\u00b14.02 D preoperatively and \u22120.14\u00b10.38 D at 3 months. Mean absolute value of the measured axis misalignment from baseline (day 1) to 1 month was 2.90\u00b12.11\u00ba and from 1 month to 3 months was 4.6\u00b111.2\u00b0. Mean absolute value of the measured changes in axis misalignment from baseline to 3 months was 2.68\u00b12.11\u00b0 (after excluding one eye that required repositioning due to TICL rotation). At 3 months postoperatively, 96.8% (30\/31) eyes had \u2a7d8\u00b0 and 90.3% (28\/31) had \u2a7d5\u00b0 of axis misalignment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>\n              The TICL showed minimal axis misalignment after implantation and remained stable 3 months postoperatively. [\n              <jats:italic>J Refract Surg.<\/jats:italic>\n              2009;25:S939\u2013S943.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20090915-08","type":"journal-article","created":{"date-parts":[[2009,10,22]],"date-time":"2009-10-22T14:19:44Z","timestamp":1256221184000},"source":"Crossref","is-referenced-by-count":30,"title":["Axis Alignment and Rotational Stability After Implantation of the Toric Implantable Collamer Lens for Myopic Astigmatism"],"prefix":"10.3928","volume":"25","author":[{"given":"Ayman N.","family":"Hashem","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alaa M.","family":"El Danasoury","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hamed M.","family":"Anwar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(94)31371-6"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19980501-15"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.02.025"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.058"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(03)00295-2"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.02.017"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20061102-01"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090115-06"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090422-01"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2004.03.026"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.08.049"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003470170077"},{"key":"e_1_3_2_14_2","first-page":"237","volume-title":"Foldable Intraocular Lenses","author":"Sanders DR","year":"1993","unstructured":"Sanders DR, Grabow HB, Shepherd J, Raanan MR. STAAR AA-4203T toric silicone IOL. In: Martin RG, Sanders DR, Gillis JP, eds. Foldable Intraocular Lenses. Thorofare, NJ: SLACK Incorporated; 1993:237\u2013250."},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01035-5"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)74917-7"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20090915-08","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:52:13Z","timestamp":1683085933000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20090915-08"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,10]]},"references-count":15,"journal-issue":{"issue":"S4","published-print":{"date-parts":[[2009,10]]}},"alternative-id":["10.3928\/1081597X-20090915-08"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20090915-08","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,10]]}}}