{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T17:09:21Z","timestamp":1780679361564,"version":"3.54.1"},"reference-count":27,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2009,11]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate stereoacuity before and after refractive lens exchange (RLE) with AcrySof ReSTOR intraocular lens (IOL) implantation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>\n              Stereoacuity was measured using the Titmus stereotest at 40 cm under photopic conditions (85 cd\/m\n              <jats:sup>2<\/jats:sup>\n              ) before and after RLE with bilateral AcrySof ReSTOR Natural (SN60D3 model) implantation in 30 hyperopic eyes of presbyopes with low astigmatism (\u2a7d1.00 diopter [D]). Stereoacuity measurements after implantation were compared with those found before surgery.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Stereoacuity was unchanged after RLE with pseudoaccommodative IOL implantation. In this population of non-cataractous hyperopes with excellent preoperative stereoacuity (46.42\u00b11.36 sec arc), 95% maintained the same level of stereoacuity (48.67\u00b11.13 sec arc) after surgery (\n              <jats:italic>P<\/jats:italic>\n              =.223). Further calculations predict that this ability to discriminate objects in depth extends to approximately 2 m. Beyond this distance, depth discrimination does not help the visual system.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Refractive lens exchange with AcrySof ReSTOR IOL implantation does not affect the binocular ability of the human eye regarding depth perception, the best evidence of binocular function in hyperopic individuals.<\/jats:p>\n            <jats:p>\n              [\n              <jats:italic>J Refract Surg<\/jats:italic>\n              . 2009;25:1000\u20131004.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20091016-05","type":"journal-article","created":{"date-parts":[[2009,11,18]],"date-time":"2009-11-18T22:41:43Z","timestamp":1258584103000},"page":"1000-1004","source":"Crossref","is-referenced-by-count":18,"title":["Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation"],"prefix":"10.3928","volume":"25","author":[{"given":"Teresa","family":"Ferrer-Blasco","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Mont\u00e9s-Mic\u00f3","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alejandro","family":"Cervi\u00f1o","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 F.","family":"Alfonso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 M.","family":"Gonz\u00e1lez-M\u00e9ijome","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1983.tb00622.x"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(89)90114-4"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199507000-00008"},{"key":"e_1_3_2_5_2","first-page":"593","article-title":"The threshold of stereopsis in the presence of differences in magnification of the ocular images","volume":"51","author":"Reading RW","year":"1980","unstructured":"Reading RW, Tanlamai T. The threshold of stereopsis in the presence of differences in magnification of the ocular images. J Am Optom Assoc. 1980;51:593\u2013595.","journal-title":"J Am Optom Assoc"},{"key":"e_1_3_2_6_2","first-page":"741","article-title":"Effects of aniseikonia, anisometropia, accommodation, retinal illuminance, and pupil size on stereopsis","volume":"26","author":"Lovasik JV","year":"1985","unstructured":"Lovasik JV, Szymkiw M. Effects of aniseikonia, anisometropia, accommodation, retinal illuminance, and pupil size on stereopsis. Invest Ophthalmol Vis Sci. 1985;26:741\u2013750.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-196610000-00003"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(89)90045-X"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198710000-00006"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198805000-00017"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01648-6"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00862-5"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.03.034"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.10.051"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.10.058"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3921\/joptom.2008.30"},{"key":"e_1_3_2_17_2","volume-title":"Optometry","author":"Edwards K","year":"1988","unstructured":"Edwards K, Llewellyn R. Optometry. 1st ed. London, United Kingdom: Butterworths; 1988.","edition":"1"},{"key":"e_1_3_2_18_2","volume-title":"Clinical Optics and Refraction","author":"Lehmann OJ","year":"1998","unstructured":"Lehmann OJ, Verity DH, Coombes AGA, Ah-Fat FG, Francis PJ, Ionides ACW. Clinical Optics and Refraction. 1st ed. Oxford, United Kingdom: Butterworth-Heinemann; 1998.","edition":"1"},{"key":"e_1_3_2_19_2","volume-title":"Clinical Optics","author":"Elkington AR","year":"1984","unstructured":"Elkington AR, Frank HJ. Clinical Optics. 2nd ed. London, United Kingdom: Blackwell Scientific Publications; 1984.","edition":"2"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.12.031"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.11.020"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.11.021"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.01.017"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)76346-9"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.06.046"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.02.006"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(94)00176-M"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000216098.62165.34"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/1081597X-20091016-05","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:52:58Z","timestamp":1683114778000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20091016-05"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,11]]},"references-count":27,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2009,11]]}},"alternative-id":["10.3928\/1081597X-20091016-05"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20091016-05","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,11]]}}}