{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T07:21:51Z","timestamp":1791271311370,"version":"4.1.0"},"reference-count":34,"publisher":"SLACK, Inc.","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2009,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate visual outcomes of LASIK in eyes with high astigmatic refractive errors with low spherical component.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>\n              We prospectively evaluated cross cylinder LASIK in patients with high astigmatic eyes with low spherical component over a 2-year period. All laser surgeries were performed with the NIDEK EC-5000 excimer laser. We used power vectors (M [spherical equivalent] and J\n              <jats:sub>0,<\/jats:sub>\n              and J\n              <jats:sub>45<\/jats:sub>\n              [cylinder]) to analyze the astigmatic results. Main outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and complications.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Thirty-four eyes of 22 patients were included. Patients were followed for 21.8\u00b13.7 months. At the last examination, UCVA of 20\/40 or better was observed in 33 (97.1%) eyes. Best spectacle-corrected visual acuity after LASIK improved significantly in comparison to BSCVA before surgery (\n              <jats:italic>P<\/jats:italic>\n              &lt;.005). Mean preoperative cylinder was \u22124.73\u00b10.89 diopters (D) (range: \u22124.00 to \u22127.00 D), which decreased to \u22120.29\u00b10.47 D (range: 0.00 to \u22121.50 D) at last follow-up (\n              <jats:italic>P<\/jats:italic>\n              &lt;.001). Reduction in the magnitude of power vectors was 92.4% for M, 103.2% for J\n              <jats:sub>0<\/jats:sub>\n              , and 76.4% for J\n              <jats:sub>45<\/jats:sub>\n              . No cases of postoperative astigmatic regression or corneal haze were observed.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Cross cylinder LASIK with the NIDEK EC-5000 excimer laser is a successful procedure for correcting high astigmatism and improving vision.<\/jats:p>\n            <jats:p>\n              [\n              <jats:italic>J Refract Surg<\/jats:italic>\n              . 2009;25:1075\u20131082.]\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20091117-06","type":"journal-article","created":{"date-parts":[[2009,12,15]],"date-time":"2009-12-15T21:23:46Z","timestamp":1260912226000},"page":"1075-1082","source":"Crossref","is-referenced-by-count":8,"title":["Vector Analysis of Cross Cylinder LASIK With the NIDEK EC-5000 Excimer Laser for High Astigmatism"],"prefix":"10.3928","volume":"25","author":[{"given":"Abbas","family":"Abolhassani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmad","family":"Shojaei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali Reza","family":"Baradaran-Rafiee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Medi","family":"Eslani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Behzad","family":"Elahi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farsad","family":"Noorizadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","first-page":"247","volume-title":"Custom LASIK: Surgical Techniques and Complications","author":"Doane J","year":"2003","unstructured":"Doane J. Treatment of astigmatism. In: Burrato L, Brint SF, eds. Custom LASIK: Surgical Techniques and Complications. Thorofare, NJ: SLACK Incorporated; 2003:247\u2013258."},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19930101-07"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1991.01080100050041"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010302-07"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80207-6"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00524-1"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00498-X"},{"key":"e_1_3_2_9_2","first-page":"319","volume-title":"Customized Corneal Ablation. The Quest for SuperVision","author":"Vinciguerra P","year":"2001","unstructured":"Vinciguerra P, Camesasca F. Cross-cylinder ablation. In: Mac-Rae S, Krueger RR, Applegate RA, eds. Customized Corneal Ablation. The Quest for SuperVision. Thorofare, NJ: SLACK Incorporated; 2001:319\u2013327."},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19970901-07"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.11.054"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00071-3"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2004.18.1.29"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060101-16"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20011101-13"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318157acbb"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00796-3"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2008.01287.x"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00799-9"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020101-11"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00797-5"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199706000-00019"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-30"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200102000-00011"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)72328-1"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-200343030-00015"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020501-04"},{"key":"e_1_3_2_28_2","first-page":"105","volume-title":"Refractive Surgery: A Manual of Principles and Practice","author":"Vinciguerra P","year":"2000","unstructured":"Vinciguerra P. Cross cylinder ablation for the correction of myopic or hyperopic astigmatism. In: Gimbel HV, Anderson Penno EE, eds. Refractive Surgery: A Manual of Principles and Practice. Thorofare, NJ: SLACK Incorporated; 2000:105\u2013113."},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19990302-04"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.15.002514"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00798-7"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060601-01"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.85.9.1127"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80154-X"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20010701-12"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/journals\/jrs\/2009-12-25-12\/%7B4528baa9-3ce4-4141-8cf0-c21655741762%7D\/vector-analysis-of-cross-cylinder-lasik-with-the-nidek-ec-5000-excimer-laser-for-high-astigmatism.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:55:12Z","timestamp":1683114912000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20091117-06"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12]]},"references-count":34,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["10.3928\/1081597X-20091117-06"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20091117-06","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,12]]}}}