{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T04:45:31Z","timestamp":1789015531552,"version":"build-2803163510"},"reference-count":35,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2010,9]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To present a new device, the Salzburg Reading Desk (SRD), for the standardized testing of reading acuity and reading speed at a subjectively convenient reading distance (best distance).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>First, in a systematic experimental setup, testing for validity and reliability was performed at 450 simulated reading distances (90 different test situations, each repeated 5 times) between 16 and 70 cm. The distance read-outs by the SRD software were correlated to the distances measured with a meter ruler. Second, reading distance and reading speed of 27 naturally emmetropic and presbyopic patients were evaluated using the log-scaled Radner Reading Charts implemented in the SRD.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In the experimental setup, an overall mean difference of the SRD distance read-out\u2014compared to a standard distance measurement with a meter ruler\u2014of 0.08\u00b10.13 cm was observed. In the presbyopic patients, overall mean reading distance was 49.74\u00b14.43 cm. Patients were able to read with their own subjectively convenient reading distance. A constant mean reading speed of sentences with bigger typeface (between 152.4\u00b122.6 words\/minute [wpm] and 157.3\u00b115.8 wpm) was found, but reading speed gradually diminished over time when reading sentences with smaller typeface.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The SRD seems to be a valid and reliable device for testing reading acuity at the best reading distance in an experimental setup as well as in clinical use in presbyopic patients. The SRD may be used whenever a detailed comparison of different methods for correcting presbyopia is required.<\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20091119-01","type":"journal-article","created":{"date-parts":[[2009,12,8]],"date-time":"2009-12-08T00:17:30Z","timestamp":1260231450000},"page":"682-688","source":"Crossref","is-referenced-by-count":44,"title":["Device for Improving Quantification of Reading Acuity and Reading Speed"],"prefix":"10.3928","volume":"26","author":[{"given":"Alois K.","family":"Dexl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Horst","family":"Schl\u00f6gel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Wolfbauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00fcnther","family":"Grabner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-002-0443-5"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00082-6"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.1997.tb00151.x"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-199403440-00010"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19990101-13"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-200404410-00016"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01255-1"},{"issue":"12","key":"e_1_3_2_9_2","first-page":"445","article-title":"Cause and treatment of presbyopia with a method for increasing the amplitude of accommodation","volume":"24","author":"Schachar RA","year":"1992","unstructured":"Schachar RA. Cause and treatment of presbyopia with a method for increasing the amplitude of accommodation. Ann Ophthalmol. 1992;24(12):445\u2013447,452.","journal-title":"Ann Ophthalmol"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(02)01831-7"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-200104000-00013"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.12.051"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80793-6"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(91)32205-X"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.121.12.1722"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00779-5"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.12.057"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2003.05.033"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19921101-03"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1034863"},{"key":"e_1_3_2_21_2","volume-title":"Visual acuity testing. Standard optotype and its presentation (ISO 8596:1994)","author":"Ophthalmic optics","year":"1994","unstructured":"Ophthalmic optics. Visual acuity testing. Standard optotype and its presentation (ISO 8596:1994). Berlin, Germany: Beuth-Verlag; 1994."},{"key":"e_1_3_2_22_2","first-page":"5","article-title":"Visual acuity measurement standard","author":"Colenbrander A","year":"1988","unstructured":"Colenbrander A. Visual acuity measurement standard. Ital J Ophthalmol. 1988;II\/I:5\u201319.","journal-title":"Ital J Ophthalmol"},{"key":"e_1_3_2_23_2","volume-title":"Part 3, 5 and 6. DIN 58220","author":"Visual acuity test","year":"1997","unstructured":"Visual acuity test. Part 3, 5 and 6. DIN 58220. Berlin, Germany: Beuth-Verlag; 1997."},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198006000-00011"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2008-1034969"},{"key":"e_1_3_2_26_2","first-page":"103","article-title":"Recommended standard procedures for the clinical measurement and specification of visual acuity. Report of working group 39. Committee on Vision. Assembly of Behavioral and Social Sciences, National Research Council, National Academy of Sciences, Washington, D.C","volume":"41","year":"1980","unstructured":"Recommended standard procedures for the clinical measurement and specification of visual acuity. Report of working group 39. Committee on Vision. Assembly of Behavioral and Social Sciences, National Research Council, National Academy of Sciences, Washington, D.C. Adv Ophthalmol. 1980;41:103\u2013148.","journal-title":"Adv Ophthalmol"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9394(82)90197-0"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-003-0776-8"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01488-8"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01566-X"},{"key":"e_1_3_2_31_2","volume-title":"Lighting of work places. Part 1: indoor work places (German version). DIN EN 12464-1:2003 03","author":"Light and lighting","year":"2003","unstructured":"Light and lighting. Lighting of work places. Part 1: indoor work places (German version). DIN EN 12464-1:2003 03. Berlin, Germany: Beuth-Verlag; 2003."},{"issue":"3","key":"e_1_3_2_32_2","first-page":"557","article-title":"A comprehensive assessment of visual impairment in a population of older Americans. The SEE Study. Salisbury Eye Evaluation Project","volume":"38","author":"Rubin GS","year":"1997","unstructured":"Rubin GS, West SK, Mu\u00f1oz B, Bandeen-Roche K, Zeger S, Schein D, Fried LP. A comprehensive assessment of visual impairment in a population of older Americans. The SEE Study. Salisbury Eye Evaluation Project. Invest Ophthalmol Vis Sci. 1997;38(3):557\u2013568.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199301000-00010"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000216100.93302.2d"},{"key":"e_1_3_2_36_2","first-page":"115","volume-title":"Quality of Vision: Essential Optics for the Refractive Surgeon","author":"Holladay JT","year":"2007","unstructured":"Holladay JT. Understanding neural adaptation. In: Quality of Vision: Essential Optics for the Refractive Surgeon. Thorofare, NJ: SLACK Incorporated; 2007:115\u2013122."}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.slackinc.com\/doi\/resolver.asp?doi=10.3928\/1081597X-20091119-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T07:57:00Z","timestamp":1683100620000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20091119-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,9]]},"references-count":35,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2010,9]]}},"alternative-id":["10.3928\/1081597X-20091119-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20091119-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2010,9]]}}}