{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T18:13:47Z","timestamp":1775153627217,"version":"3.50.1"},"reference-count":20,"publisher":"SLACK, Inc.","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2010,11]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate methods that determine refractive correction from wavefront data that best matches the manifest refraction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Wavefront data in the form of Zernike polynomial coefficients from several VISX US Investigational Device Exemption studies were used to calculate the spherocylindrical distance correction using four methods: full pupil second order, central curvature, reduced aperture, and 4-mm pupil. The data were analyzed in two groups, preoperative (3686 measurements, 882 eyes) and 6-month postoperative (2570 measurements, 797 eyes). Differences were formed between values found with each method and the manifest refractive values for the spherical equivalent (dSE), cylinder power (dCc), and axis power (dAc). The wavefront spherical equivalent values were corrected for chromatic shift, lane length, and vertex.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>\n              Values derived using the reduced aperture and 4-mm pupil methods corresponded with manifest spherical equivalent values for both preoperative (\n              <jats:italic>x\u0304<\/jats:italic>\n              =\u22120.03 diopters [D],\n              <jats:italic>x\u0304<\/jats:italic>\n              =0.95 D) and postoperative (\n              <jats:italic>x\u0304<\/jats:italic>\n              =\u22120.36 D,\n              <jats:italic>x\u0304<\/jats:italic>\n              =0.65 D) data. The full pupil second order method results corresponded best with manifest data for the astigmatic variables for both preoperative (\n              <jats:italic>x\u0304 dCc<\/jats:italic>\n              =0.15 D, \u03c3\n              <jats:italic>dCc<\/jats:italic>\n              =0.31 D,\n              <jats:italic>x\u0304 dAc<\/jats:italic>\n              = 0.02 D, \u03c3\n              <jats:italic>dAc<\/jats:italic>\n              =0.22 D) and postoperative data (\n              <jats:italic>x\u0304 dCc<\/jats:italic>\n              =0.25 D, \u03c3\n              <jats:italic>dCc<\/jats:italic>\n              =0.33 D,\n              <jats:italic>x\u0304 dAc<\/jats:italic>\n              =0.01 D, \u03c3\n              <jats:italic>dAc<\/jats:italic>\n              =0.21 D). However, all methods did well on these variables.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The Zernike coefficient set as measured best calculates the astigmatic correction. The Zernike coefficient set resized to a 4-mm pupil is best in determining spherical equivalent.<\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20091209-05","type":"journal-article","created":{"date-parts":[[2009,12,22]],"date-time":"2009-12-22T19:14:29Z","timestamp":1261509269000},"page":"881-890","source":"Crossref","is-referenced-by-count":14,"title":["Determining Spherocylindrical Correction Using Four Different Wavefront Error Analysis Methods: Comparison to Manifest Refraction"],"prefix":"10.3928","volume":"26","author":[{"given":"Charles E.","family":"Campbell","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","unstructured":"US FDA Summary of Safety and Effectiveness Data. Available at: http:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930016S016b.pdf. Accessed July 2009."},{"key":"e_1_3_1_3_2","unstructured":"US FDA Summary of Safety and Effectiveness Data. Available at: http:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930016S021b.pdf. Accessed July 2009."},{"key":"e_1_3_1_4_2","unstructured":"US FDA Summary of Safety and Effectiveness Data. Available at: http:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930016s025b.pdf. Accessed July 2009."},{"key":"e_1_3_1_5_2","unstructured":"US FDA Summary of Safety and Effectiveness Data. Available at: http:\/\/www.fda.gov\/ohrms\/dockets\/dockets\/05m0151\/05m-0151-aav0001-03-SSED-vol1.pdf. Accessed July 2009."},{"key":"e_1_3_1_6_2","unstructured":"US FDA Summary of Safety and Effectiveness Data. Available at: http:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930016S017b.pdf. Accessed July 2009."},{"key":"e_1_3_1_7_2","unstructured":"Methods for reporting optical aberrations of eyes ANSI Z80.28-2004. American National Standards Institute (2004)."},{"key":"e_1_3_1_8_2","unstructured":"Ophthalmic optics and instruments\u2014reporting aberrations of the human eye ISO 24157:2008. International Standards Organization (2008)."},{"key":"e_1_3_1_9_2","volume-title":"Poster presentation: Association for Research in Vision and Ophthalmology annual meeting","author":"Coe C","unstructured":"Coe C. Psychophysical determination of the wavelength of light that is focused by a polychromatic subjective refraction. Poster presentation: Association for Research in Vision and Ophthalmology annual meeting; May 1\u20135, 2005; Ft Lauderdale, FL."},{"key":"e_1_3_1_10_2","volume-title":"Poster presentation: Association for Research in Vision and Ophthalmology annual meeting","author":"DeHoog E","unstructured":"DeHoog E, Schwiegerling J. Position of white light best focus in the human eye. Poster presentation: Association for Research in Vision and Ophthalmology annual meeting; May 6\u201310, 2007; Ft Lauderdale, FL."},{"key":"e_1_3_1_11_2","volume-title":"Presented at: Mopane Conference","author":"Campbell CE","unstructured":"Campbell CE. Polychromatism of the eye: a method to include its effects into the aberrations of the eye of all orders, its effect on aberrations of the eye and its effect on the depth of focus of the eye. Presented at: Mopane Conference; August 2\u20135, 2003; Mopane, South Africa."},{"key":"e_1_3_1_12_2","first-page":"1","volume-title":"Handbook of Optics","author":"Charman WN","year":"1995","unstructured":"Charman WN. Optics of the eye. In: , Bass M, ed. Handbook of Optics. Vol 1. New York, NY: McGraw-Hill; 1995:1\u201340."},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.19.002329"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.20.000209"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.23.000539"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.24.000569"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199904000-00030"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199808000-00028"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198206000-00012"},{"key":"e_1_3_1_20_2","first-page":"2325","article-title":"The repeatability of measure of the ocular components","volume":"33","author":"Zadnik K","year":"1992","unstructured":"Zadnik K, Mutti DO, Adams AJ. The repeatability of measure of the ocular components. Invest Ophthalmol Vis Sci. 1992;33:2325\u20132333.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_1_21_2","first-page":"947","article-title":"The reliability of automated and clinical refraction","volume":"36","author":"Adams C","year":"1995","unstructured":"Adams C, Bullimore MA, Fusaro RE, Cotteral RM, Sarver J, Graham AD. The reliability of automated and clinical refraction. Invest Ophthalmol Vis Sci. 1995;36(Suppl):947.","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.slackinc.com\/doi\/resolver.asp?doi=10.3928\/1081597X-20091209-05","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:41:35Z","timestamp":1683114095000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20091209-05"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11]]},"references-count":20,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2010,11]]}},"alternative-id":["10.3928\/1081597X-20091209-05"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20091209-05","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2010,11]]}}}