{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T06:40:22Z","timestamp":1777617622671,"version":"3.51.4"},"reference-count":26,"publisher":"SLACK, Inc.","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2010,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To assess efficacy, safety, predictability, stability, and patient satisfaction after presbyopic lens exchange in emmetropic patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A prospective, nonrandomized, masked, observational case series (self-controlled) of 46 emmetropic eyes of 23 consecutive patients (age range: 50 to 60 years) after presbyopic lens exchange with bilateral AcrySof ReSTOR Natural (SN60D3) intraocular lens (IOL) (Alcon Laboratories Inc) implantation were evaluated. Mean spherical equivalent refraction (SE) was \u22120.04\u00b10.14 diopters (D) (range: +0.25 to \u22120.25 D). Monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), distance-corrected near visual acuity (DCNVA), and patient satisfaction were recorded preoperatively and 6 months after surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>At 6 months postoperative, efficacy index at distance was 1.00. No eye lost \u22652 lines of CDVA, 5 eyes lost 1 line, 24 eyes did not change after surgery, 14 eyes gained 1 line, and 3 eyes gained 2 lines of visual acuity. Safety index at distance was 1.03. All eyes had a manifest SE within \u00b10.50 D of emmetropia. Mean postoperative SE was +0.14\u00b10.22 D (range: \u22120.25 to +0.37 D). No eye lost &gt;2 lines of DCNVA, 1 eye lost 2 lines, 3 eyes lost 1 line, 34 eyes did not change after surgery, and 8 eyes gained 1 line of visual acuity. Uncorrected near visual acuity was 0.95\u00b10.07. Safety and efficacy indexes at near were 1.01 and 1.03, respectively. A patient satisfaction questionnaire showed that patients had a high level of satisfaction after presbyopic lens exchange surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Presbyopic lens exchange with implantation of the ReSTOR multifocal IOL in emmetropic eyes is an effective and safe procedure for presbyopia correction.<\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/1081597x-20100114-01","type":"journal-article","created":{"date-parts":[[2010,2,3]],"date-time":"2010-02-03T16:29:37Z","timestamp":1265214577000},"page":"927-933","source":"Crossref","is-referenced-by-count":33,"title":["Outcomes and Patient Satisfaction After Presbyopic Bilateral Lens Exchange with the ResTOR IOL in Emmetropic Patients"],"prefix":"10.3928","volume":"26","author":[{"given":"Jos\u00e9 F.","family":"Alfonso","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lu\u00eds","family":"Fern\u00e1ndez-Vega","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Beatriz","family":"Valc\u00e1rcel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teresa","family":"Ferrer-Blasco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Mont\u00e9s-Mic\u00f3","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.10.058"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01093-8"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20020901-04"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.10.020"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.06.028"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.11.056"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.03.022"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.03.034"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.01.026"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3921\/joptom.2008.30"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.01.014"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90526-2"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00794-2"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2004.052720"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00722-X"},{"key":"e_1_3_2_17_2","first-page":"CD003169","article-title":"Multifocal versus monofocal intraocular lenses after cataract extraction","volume":"4","author":"Leyland M","year":"2006","unstructured":"Leyland M, Zinicola E. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2006;4:CD003169.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.03.041"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00862-5"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.10.051"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80706-7"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00376-X"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.11.020"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.12.031"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.04.011"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.01.017"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.3921\/joptom.2008.22"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.slackinc.com\/doi\/resolver.asp?doi=10.3928\/1081597X-20100114-01","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T11:42:35Z","timestamp":1683114155000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20100114-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,12]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2010,12]]}},"alternative-id":["10.3928\/1081597X-20100114-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20100114-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2010,12]]}}}